Accuracy of UK Rapid Test Consortium (UK-RTC) "AbC-19 Rapid Test" for detection of previous SARS-CoV-2 infection in key workers: test accuracy study. (11th November 2020)
- Record Type:
- Journal Article
- Title:
- Accuracy of UK Rapid Test Consortium (UK-RTC) "AbC-19 Rapid Test" for detection of previous SARS-CoV-2 infection in key workers: test accuracy study. (11th November 2020)
- Main Title:
- Accuracy of UK Rapid Test Consortium (UK-RTC) "AbC-19 Rapid Test" for detection of previous SARS-CoV-2 infection in key workers: test accuracy study
- Authors:
- Mulchandani, Ranya
Jones, Hayley E
Taylor-Phillips, Sian
Shute, Justin
Perry, Keith
Jamarani, Shabnam
Brooks, Tim
Charlett, Andre
Hickman, Matthew
Oliver, Isabel
Kaptoge, Stephen
Danesh, John
Di Angelantonio, Emanuele
Ades, Anthony E
Wyllie, David H - Other Names:
- author non-byline.
Armitage Jane author non-byline.
Borrow Ray author non-byline.
Boyes John author non-byline.
Cullen Donna author non-byline.
Hormis Anil author non-byline.
Linley Ezra author non-byline.
Mehenny Susan author non-byline.
Miflin Gail author non-byline.
Moore Carmel author non-byline.
Moore Philippa author non-byline.
Reckless Ian author non-byline.
Roberts David J author non-byline.
Sambrook Jennifer author non-byline.
Todd Neil author non-byline. - Abstract:
- Abstract: Objective: To assess the accuracy of the AbC-19 Rapid Test lateral flow immunoassay for the detection of previous severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. Design: Test accuracy study. Setting: Laboratory based evaluation. Participants: 2847 key workers (healthcare staff, fire and rescue officers, and police officers) in England in June 2020 (268 with a previous polymerase chain reaction (PCR) positive result (median 63 days previously), 2579 with unknown previous infection status); and 1995 pre-pandemic blood donors. Main outcome measures: AbC-19 sensitivity and specificity, estimated using known negative (pre-pandemic) and known positive (PCR confirmed) samples as reference standards and secondly using the Roche Elecsys anti-nucleoprotein assay, a highly sensitive laboratory immunoassay, as a reference standard in samples from key workers. Results: Test result bands were often weak, with positive/negative discordance by three trained laboratory staff for 3.9% of devices. Using consensus readings, for known positive and negative samples sensitivity was 92.5% (95% confidence interval 88.8% to 95.1%) and specificity was 97.9% (97.2% to 98.4%). Using an immunoassay reference standard, sensitivity was 94.2% (90.7% to 96.5%) among PCR confirmed cases but 84.7% (80.6% to 88.1%) among other people with antibodies. This is consistent with AbC-19 being more sensitive when antibody concentrations are higher, as people with PCR confirmationAbstract: Objective: To assess the accuracy of the AbC-19 Rapid Test lateral flow immunoassay for the detection of previous severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. Design: Test accuracy study. Setting: Laboratory based evaluation. Participants: 2847 key workers (healthcare staff, fire and rescue officers, and police officers) in England in June 2020 (268 with a previous polymerase chain reaction (PCR) positive result (median 63 days previously), 2579 with unknown previous infection status); and 1995 pre-pandemic blood donors. Main outcome measures: AbC-19 sensitivity and specificity, estimated using known negative (pre-pandemic) and known positive (PCR confirmed) samples as reference standards and secondly using the Roche Elecsys anti-nucleoprotein assay, a highly sensitive laboratory immunoassay, as a reference standard in samples from key workers. Results: Test result bands were often weak, with positive/negative discordance by three trained laboratory staff for 3.9% of devices. Using consensus readings, for known positive and negative samples sensitivity was 92.5% (95% confidence interval 88.8% to 95.1%) and specificity was 97.9% (97.2% to 98.4%). Using an immunoassay reference standard, sensitivity was 94.2% (90.7% to 96.5%) among PCR confirmed cases but 84.7% (80.6% to 88.1%) among other people with antibodies. This is consistent with AbC-19 being more sensitive when antibody concentrations are higher, as people with PCR confirmation tended to have more severe disease whereas only 62% (218/354) of seropositive participants had had symptoms. If 1 million key workers were tested with AbC-19 and 10% had actually been previously infected, 84 700 true positive and 18 900 false positive results would be projected. The probability that a positive result was correct would be 81.7% (76.8% to 85.8%). Conclusions: AbC-19 sensitivity was lower among unselected populations than among PCR confirmed cases of SARS-CoV-2, highlighting the scope for overestimation of assay performance in studies involving only PCR confirmed cases, owing to "spectrum bias." Assuming that 10% of the tested population have had SARS-CoV-2 infection, around one in five key workers testing positive with AbC-19 would be false positives. Study registration: ISRCTN 56609224. … (more)
- Is Part Of:
- BMJ. Volume 371(2020)
- Journal:
- BMJ
- Issue:
- Volume 371(2020)
- Issue Display:
- Volume 371, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 371
- Issue:
- 2020
- Issue Sort Value:
- 2020-0371-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11-11
- Subjects:
- Medicine -- Periodicals
Medicine -- Periodicals
Medicine
Periodicals
610 - Journal URLs:
- http://www.bmj.com/archive ↗
http://www.jstor.org/journals/09598138.html ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/3/ ↗
http://www.bmj.com/bmj/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bmj.m4262 ↗
- Languages:
- English
- ISSNs:
- 0007-1447
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25260.xml