Implantable loop recorder follow-up. (14th October 2021)
- Record Type:
- Journal Article
- Title:
- Implantable loop recorder follow-up. (14th October 2021)
- Main Title:
- Implantable loop recorder follow-up
- Authors:
- Pena Mellado, J
Macias, R
Tercedor, L
Alvarez Lopez, M - Abstract:
- Abstract: Introduction: Long ambulatory ECG monitoring can be a useful component in the evaluation of the patient with unexplained syncope or syncope with suspected arrhythmic origin, as well as a sensitive tool for detecting asymptomatic spontaneous cardiac arrhythmias or conduction abnormalities in predisposed patients. Purpose: To determine the diagnostic cost-effectiveness of the implantable loop recorder (ILR) in the origin of unexplained syncope in our center. Methods: A retrospective observational study was carried out in a tertiary center, those patients with an ILR between August 2014 and March 2021 were included. Baseline characteristics of the population and their previous ECG, arrythmias detected during follow-up and pacemaker implant rate were evaluated. Results: One hundred twenty-seven patients with a ILR were included (age 67 years, 49.6% males). Most often cause of ILR was unexplained syncope (90.6%) followed by monitoring after TAVI implant (3.9%). Normal LVEF (>50%) was present in 85.6%, and 75.6% had NYHA I functional class. 118 patients (92.9%) presented sinus rhythm at implant time, and 8 (6.3%) presented AF. 12.6% presented first degree atrioventricular (AV) block, 2 patients (1.6%) had presented previously Mobitz Type I AV block and one patient 2:1 block. Left bundle branch block (LBBB) was present in 13.4%, RBBB in 3.1%, LAFB in 9.4%, RBBB+LAFB in 11% and RBBB+LPFB in 2.4%. Median time of follow-up was 21 months. 3rd degree AV block was the mostAbstract: Introduction: Long ambulatory ECG monitoring can be a useful component in the evaluation of the patient with unexplained syncope or syncope with suspected arrhythmic origin, as well as a sensitive tool for detecting asymptomatic spontaneous cardiac arrhythmias or conduction abnormalities in predisposed patients. Purpose: To determine the diagnostic cost-effectiveness of the implantable loop recorder (ILR) in the origin of unexplained syncope in our center. Methods: A retrospective observational study was carried out in a tertiary center, those patients with an ILR between August 2014 and March 2021 were included. Baseline characteristics of the population and their previous ECG, arrythmias detected during follow-up and pacemaker implant rate were evaluated. Results: One hundred twenty-seven patients with a ILR were included (age 67 years, 49.6% males). Most often cause of ILR was unexplained syncope (90.6%) followed by monitoring after TAVI implant (3.9%). Normal LVEF (>50%) was present in 85.6%, and 75.6% had NYHA I functional class. 118 patients (92.9%) presented sinus rhythm at implant time, and 8 (6.3%) presented AF. 12.6% presented first degree atrioventricular (AV) block, 2 patients (1.6%) had presented previously Mobitz Type I AV block and one patient 2:1 block. Left bundle branch block (LBBB) was present in 13.4%, RBBB in 3.1%, LAFB in 9.4%, RBBB+LAFB in 11% and RBBB+LPFB in 2.4%. Median time of follow-up was 21 months. 3rd degree AV block was the most frequent arrhythmia detected (12.1%), followed by >3s pause (8%) and previously unknown AF (2.4%).The patients with syncope who suffered head trauma (33%) presented a higher rate of pacemaker (PCM) implant compared to those without head trauma: 31.6% vs 14.7%. In total, 19.8% PCM rate implant during follow-up. No complications ILR related. Conclusion: In conclusion, long home ECG monitoring with ILR is a powerful and helpful tool to find out or rule out potentially dangerous arrhythmias as cause of syncope, with no complications in our experience. Funding Acknowledgement: Type of funding sources: None. … (more)
- Is Part Of:
- European heart journal. Volume 42(2021)Supplement 1
- Journal:
- European heart journal
- Issue:
- Volume 42(2021)Supplement 1
- Issue Display:
- Volume 42, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2021-0042-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-14
- Subjects:
- Implantable Loop Recorder
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehab724.0318 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25253.xml