Diagnostic accuracy of D-dimer to detect left atrial thrombus in patients with atrial fibrillation: a systematic review and meta-analysis. (14th October 2021)
- Record Type:
- Journal Article
- Title:
- Diagnostic accuracy of D-dimer to detect left atrial thrombus in patients with atrial fibrillation: a systematic review and meta-analysis. (14th October 2021)
- Main Title:
- Diagnostic accuracy of D-dimer to detect left atrial thrombus in patients with atrial fibrillation: a systematic review and meta-analysis
- Authors:
- Diaz-Arocutipa, C
Gonzales-Luna, A.C
Branez-Condorena, A
Hernandez, A.V - Abstract:
- Abstract: Background: There is limited evidence on the use of biomarkers to diagnose left atrial thrombus in atrial fibrillation. Purpose: We evaluated the diagnostic accuracy of D-dimer to detect left atrial thrombus in patients with atrial fibrillation. Methods: We searched four electronic databases from inception to December 16, 2020 for observational studies evaluating diagnostic accuracy of D-dimer. Reference standard was left atrial thrombus detected by transesophageal echocardiography. Study quality was assessed with the QUADAS-2 tool. We performed a bivariate random-effects meta-analysis to calculate the pooled sensitivity and specificity with their 95% confidence intervals (95% CI). In addition, a summary receiver operating characteristic curve and optimal cut-off were estimated. Results: Eleven cross-sectional studies involving 4380 patients were included. The mean age ranged from 49.8 to 74.1 years and 70% of patients were men. Left atrial thrombus was present in 7% of cases. In seven studies, the pooled sensitivity of D-dimer at 500 ng/mL was 53% (95% CI, 26–79%) and the pooled specificity was 92% (95% CI, 80–97%). The pooled sensitivity of age-adjusted D-dimer was 35% (95% CI, 18–57%) and the pooled specificity was 100% (95% CI, 100–100%) in two studies. The optimal cut-off was 390 ng/mL in 10 studies with a pooled sensitivity of 68% (95% CI, 44–85%) and a pooled specificity of 73% (95% CI, 54–86%). The risk of bias was low or unclear for all domains. ConcernsAbstract: Background: There is limited evidence on the use of biomarkers to diagnose left atrial thrombus in atrial fibrillation. Purpose: We evaluated the diagnostic accuracy of D-dimer to detect left atrial thrombus in patients with atrial fibrillation. Methods: We searched four electronic databases from inception to December 16, 2020 for observational studies evaluating diagnostic accuracy of D-dimer. Reference standard was left atrial thrombus detected by transesophageal echocardiography. Study quality was assessed with the QUADAS-2 tool. We performed a bivariate random-effects meta-analysis to calculate the pooled sensitivity and specificity with their 95% confidence intervals (95% CI). In addition, a summary receiver operating characteristic curve and optimal cut-off were estimated. Results: Eleven cross-sectional studies involving 4380 patients were included. The mean age ranged from 49.8 to 74.1 years and 70% of patients were men. Left atrial thrombus was present in 7% of cases. In seven studies, the pooled sensitivity of D-dimer at 500 ng/mL was 53% (95% CI, 26–79%) and the pooled specificity was 92% (95% CI, 80–97%). The pooled sensitivity of age-adjusted D-dimer was 35% (95% CI, 18–57%) and the pooled specificity was 100% (95% CI, 100–100%) in two studies. The optimal cut-off was 390 ng/mL in 10 studies with a pooled sensitivity of 68% (95% CI, 44–85%) and a pooled specificity of 73% (95% CI, 54–86%). The risk of bias was low or unclear for all domains. Concerns regarding applicability were generally low for almost all studies Conclusion: Our meta-analysis suggests that D-dimer has the potential to be useful to the detection of left atrial thrombus in patients with atrial fibrillation. Funding Acknowledgement: Type of funding sources: None. … (more)
- Is Part Of:
- European heart journal. Volume 42(2021)Supplement 1
- Journal:
- European heart journal
- Issue:
- Volume 42(2021)Supplement 1
- Issue Display:
- Volume 42, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2021-0042-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-14
- Subjects:
- Diagnostic Methods
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehab724.0485 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25253.xml