The reliability of hearing implants: report on the type and incidence of cochlear implant failures. (3rd July 2020)
- Record Type:
- Journal Article
- Title:
- The reliability of hearing implants: report on the type and incidence of cochlear implant failures. (3rd July 2020)
- Main Title:
- The reliability of hearing implants: report on the type and incidence of cochlear implant failures
- Authors:
- Van de Heyning, Paul
Atlas, Marcus
Baumgartner, Wolf-Dieter
Caversaccio, Marco
Gavilan, Javier
Godey, Benoit
Gstöttner, Wolfgang
Hagen, Rudolph
Yongxin, Li
Karltorp, Eva
Kameswaran, Mohan
Kuzovkov, Vlad
Lassaletta, Luis
Manoj, Manikoth
Parnes, Lorne
Pillsbury, Harold
Raine, Christopher
Rajan, Gunesh
Schmutzhard, Joachim
Skarzynski, Henryk
Staecker, Hinrich
Usami, Shin-ichi
Zernotti, Mario - Abstract:
- Abstract : Objectives: This study presents the data collected through a database on the type and incidence of cochlear implant device failures and major complications and quantifies the risk of failures across time based on the Association for the Advancement of Medical Instrumentation (AAMI) CI86:2017 standard. Methods: Information on reliability of MED-EL cochlear implants was collected from the MED-EL complaint database between 2003 and2013. Explants were categorized and device reliability was calculated according to the AAMI CI86:2017 standard principles. Results: Data were collected for 11662 devices (5462 children, 6200 adults). The mean duration of follow up was 46.16 months. The total failure rate for all devices and all subjects was 2.41%. Medical related explants (MRE) were significantly worse for children than for adults with the ceramic implants, C40+ ( p = 0.008) and PULSAR ( p = 0.020). Device failure explants (DFE) were significantly worse for children than for adults with all four devices in the study, the C40+ ( p < 0.001), PULSAR ( p < 0.001), SONATA ( p < 0.001), and CONCERTO ( p = 0.023). The mean annual failure rate for all subjects and devices was 0.63% (1.03% for children, 0.28% for adults). The mean annual failure rate was 0.90% for the C40+; 0.57% for the PULSAR; 0.46% for the SONATA; and 0.39% for the CONCERTO. Conclusions: Compared to adults, children had significantly worse MRE and DFE due to a higher risk of head trauma and more vulnerableAbstract : Objectives: This study presents the data collected through a database on the type and incidence of cochlear implant device failures and major complications and quantifies the risk of failures across time based on the Association for the Advancement of Medical Instrumentation (AAMI) CI86:2017 standard. Methods: Information on reliability of MED-EL cochlear implants was collected from the MED-EL complaint database between 2003 and2013. Explants were categorized and device reliability was calculated according to the AAMI CI86:2017 standard principles. Results: Data were collected for 11662 devices (5462 children, 6200 adults). The mean duration of follow up was 46.16 months. The total failure rate for all devices and all subjects was 2.41%. Medical related explants (MRE) were significantly worse for children than for adults with the ceramic implants, C40+ ( p = 0.008) and PULSAR ( p = 0.020). Device failure explants (DFE) were significantly worse for children than for adults with all four devices in the study, the C40+ ( p < 0.001), PULSAR ( p < 0.001), SONATA ( p < 0.001), and CONCERTO ( p = 0.023). The mean annual failure rate for all subjects and devices was 0.63% (1.03% for children, 0.28% for adults). The mean annual failure rate was 0.90% for the C40+; 0.57% for the PULSAR; 0.46% for the SONATA; and 0.39% for the CONCERTO. Conclusions: Compared to adults, children had significantly worse MRE and DFE due to a higher risk of head trauma and more vulnerable skull anatomy. Further, the authors conclude that the AAMI standard will ensure a more comprehensive and transparent evaluation of cochlear implant reliability in the future. … (more)
- Is Part Of:
- Cochlear implants international. Volume 21:Number 4(2020)
- Journal:
- Cochlear implants international
- Issue:
- Volume 21:Number 4(2020)
- Issue Display:
- Volume 21, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 21
- Issue:
- 4
- Issue Sort Value:
- 2020-0021-0004-0000
- Page Start:
- 228
- Page End:
- 237
- Publication Date:
- 2020-07-03
- Subjects:
- Failure analysis -- Device failure -- Explant -- Adults -- Children -- Cochlear Implant
Cochlear implants -- Periodicals
617.882 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1556-9152 ↗
http://www.ingenta.com/journals/browse/whurr/cii ↗
http://www.ingentaconnect.com/content/maney/cii ↗
http://www.tandfonline.com/loi/ycii20 ↗
http://maneypublishing.com/ ↗ - DOI:
- 10.1080/14670100.2020.1735678 ↗
- Languages:
- English
- ISSNs:
- 1467-0100
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3292.724200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25215.xml