Colorectal cancer screening with faecal immunochemical testing, sigmoidoscopy or colonoscopy: a microsimulation modelling study. (2nd October 2019)
- Record Type:
- Journal Article
- Title:
- Colorectal cancer screening with faecal immunochemical testing, sigmoidoscopy or colonoscopy: a microsimulation modelling study. (2nd October 2019)
- Main Title:
- Colorectal cancer screening with faecal immunochemical testing, sigmoidoscopy or colonoscopy: a microsimulation modelling study
- Authors:
- Buskermolen, Maaike
Cenin, Dayna R
Helsingen, Lise M
Guyatt, Gordon
Vandvik, Per Olav
Haug, Ulrike
Bretthauer, Michael
Lansdorp-Vogelaar, Iris - Abstract:
- Abstract: Objective: To estimate benefits and harms of different colorectal cancer screening strategies, stratified by (baseline) 15-year colorectal cancer risk. Design: Microsimulation modelling study using MIcrosimulation SCreening ANalysis-Colon (MISCAN-Colon). Setting: A parallel guideline committee ( BMJ Rapid Recommendations) defined the time frame and screening interventions, including selection of outcome measures. Population: Norwegian men and women aged 50-79 years with varying 15-year colorectal cancer risk (1-7%). Comparisons: Four screening strategies were compared with no screening: biennial or annual faecal immunochemical test (FIT) or single sigmoidoscopy or colonoscopy at 100% adherence. Main outcome measures: Colorectal cancer mortality and incidence, burdens, and harms over 15 years of follow-up. The certainty of the evidence was assessed using the GRADE approach. Results: Over 15 years of follow-up, screening individuals aged 50-79 at 3% risk of colorectal cancer with annual FIT or single colonoscopy reduced colorectal cancer mortality by 6 per 1000 individuals. Single sigmoidoscopy and biennial FIT reduced it by 5 per 1000 individuals. Colonoscopy, sigmoidoscopy, and annual FIT reduced colorectal cancer incidence by 10, 8, and 4 per 1000 individuals, respectively. The estimated incidence reduction for biennial FIT was 1 per 1000 individuals. Serious harms were estimated to be between 3 per 1000 (biennial FIT) and 5 per 1000 individuals (colonoscopy);Abstract: Objective: To estimate benefits and harms of different colorectal cancer screening strategies, stratified by (baseline) 15-year colorectal cancer risk. Design: Microsimulation modelling study using MIcrosimulation SCreening ANalysis-Colon (MISCAN-Colon). Setting: A parallel guideline committee ( BMJ Rapid Recommendations) defined the time frame and screening interventions, including selection of outcome measures. Population: Norwegian men and women aged 50-79 years with varying 15-year colorectal cancer risk (1-7%). Comparisons: Four screening strategies were compared with no screening: biennial or annual faecal immunochemical test (FIT) or single sigmoidoscopy or colonoscopy at 100% adherence. Main outcome measures: Colorectal cancer mortality and incidence, burdens, and harms over 15 years of follow-up. The certainty of the evidence was assessed using the GRADE approach. Results: Over 15 years of follow-up, screening individuals aged 50-79 at 3% risk of colorectal cancer with annual FIT or single colonoscopy reduced colorectal cancer mortality by 6 per 1000 individuals. Single sigmoidoscopy and biennial FIT reduced it by 5 per 1000 individuals. Colonoscopy, sigmoidoscopy, and annual FIT reduced colorectal cancer incidence by 10, 8, and 4 per 1000 individuals, respectively. The estimated incidence reduction for biennial FIT was 1 per 1000 individuals. Serious harms were estimated to be between 3 per 1000 (biennial FIT) and 5 per 1000 individuals (colonoscopy); harms increased with older age. The absolute benefits of screening increased with increasing colorectal cancer risk, while harms were less affected by baseline risk. Results were sensitive to the setting defined by the guideline panel. Because of uncertainty associated with modelling assumptions, we applied a GRADE rating of low certainty evidence to all estimates. Conclusions: Over a 15 year period, all screening strategies may reduce colorectal cancer mortality to a similar extent. Colonoscopy and sigmoidoscopy may also reduce colorectal cancer incidence, while FIT shows a smaller incidence reduction. Harms are rare and of similar magnitude for all screening strategies. … (more)
- Is Part Of:
- BMJ. Volume 367(2019)
- Journal:
- BMJ
- Issue:
- Volume 367(2019)
- Issue Display:
- Volume 367, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 367
- Issue:
- 2019
- Issue Sort Value:
- 2019-0367-2019-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-10-02
- Subjects:
- Medicine -- Periodicals
Medicine -- Periodicals
Medicine
Periodicals
610 - Journal URLs:
- http://www.bmj.com/archive ↗
http://www.jstor.org/journals/09598138.html ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/3/ ↗
http://www.bmj.com/bmj/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bmj.l5383 ↗
- Languages:
- English
- ISSNs:
- 0007-1447
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25212.xml