Additional left ventricular septal lead facilitates R-wave sensing of implantable cardioverter-defibrillator in arrhythmogenic right ventricular cardiomyopathy: a case report. Issue 1 (4th January 2023)
- Record Type:
- Journal Article
- Title:
- Additional left ventricular septal lead facilitates R-wave sensing of implantable cardioverter-defibrillator in arrhythmogenic right ventricular cardiomyopathy: a case report. Issue 1 (4th January 2023)
- Main Title:
- Additional left ventricular septal lead facilitates R-wave sensing of implantable cardioverter-defibrillator in arrhythmogenic right ventricular cardiomyopathy: a case report
- Authors:
- Lu, Wenzhao
Chen, Keping
Dai, Yan
Zhang, Shu - Editors:
- Schönbauer, Robert
Green, Peregrine
Canpolat, Ugur
Liu, Zhiyu
Costa, Gonçalo - Abstract:
- Abstract: Background: Implantable cardioverter-defibrillator (ICD) implantation is a key therapeutic option in arrhythmogenic right ventricular cardiomyopathy (ARVC) to prevent sudden cardiac death due to ventricular tachycardia (VT) and fibrillation (VF). However, sub-optimized R-wave sensing due to myocardium loss interferes with VT/VF identification and appropriate therapy. We tried to implant a 3830 lead to the left ventricular septum (LVS) to facilitate ICD sensing in an ARVC patient. Case summary: A 68-year-old woman diagnosed with ARVC was scheduled to undergo ICD implantation. Initially, no sites with suitable R-wave amplitudes were found in the right ventricle (RV) to deploy the defibrillation lead (<3.0 mV). It was likely due to severe RV involvement, but the LVS myocardium was more preserved based on cardiac magnetic resonance imaging. Therefore, we implanted a 3830 lead into the deep area of the septum to facilitate R-wave sensing. During the procedure from the right to left septum, the R-wave amplitude significantly increased (2.6 to 4.3–7.1 mV). Left ventricular septum pacing was finally achieved with favourable R-wave sensing (9.9 mV 24 h post-operation). The 3830 lead was plugged into the IS-1 port, while the defibrillation lead was plugged into the DF-1 port. After a 4-month follow-up, the R-wave amplitude of the 3830 lead was 11.1 mV. Discussion: When the R-wave sensing is not acceptable for ICD implantation in ARVC patients, it is critical to assessAbstract: Background: Implantable cardioverter-defibrillator (ICD) implantation is a key therapeutic option in arrhythmogenic right ventricular cardiomyopathy (ARVC) to prevent sudden cardiac death due to ventricular tachycardia (VT) and fibrillation (VF). However, sub-optimized R-wave sensing due to myocardium loss interferes with VT/VF identification and appropriate therapy. We tried to implant a 3830 lead to the left ventricular septum (LVS) to facilitate ICD sensing in an ARVC patient. Case summary: A 68-year-old woman diagnosed with ARVC was scheduled to undergo ICD implantation. Initially, no sites with suitable R-wave amplitudes were found in the right ventricle (RV) to deploy the defibrillation lead (<3.0 mV). It was likely due to severe RV involvement, but the LVS myocardium was more preserved based on cardiac magnetic resonance imaging. Therefore, we implanted a 3830 lead into the deep area of the septum to facilitate R-wave sensing. During the procedure from the right to left septum, the R-wave amplitude significantly increased (2.6 to 4.3–7.1 mV). Left ventricular septum pacing was finally achieved with favourable R-wave sensing (9.9 mV 24 h post-operation). The 3830 lead was plugged into the IS-1 port, while the defibrillation lead was plugged into the DF-1 port. After a 4-month follow-up, the R-wave amplitude of the 3830 lead was 11.1 mV. Discussion: When the R-wave sensing is not acceptable for ICD implantation in ARVC patients, it is critical to assess myocardial conditions comprehensively. If the septal myocardium is preserved, implanting a 3830 lead to the deep or LVS is feasible to improve R-wave sensing. … (more)
- Is Part Of:
- European heart journal. Volume 7:Issue 1(2023)
- Journal:
- European heart journal
- Issue:
- Volume 7:Issue 1(2023)
- Issue Display:
- Volume 7, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 7
- Issue:
- 1
- Issue Sort Value:
- 2023-0007-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-01-04
- Subjects:
- Arrhythmogenic right ventricular cardiomyopathy -- Implantable cardioverter-defibrillator -- R-wave sensing -- left ventricular septal pacing -- Case report
Cardiology -- Periodicals
Cardiology -- Case studies -- Periodicals
Heart -- Diseases -- Periodicals
Heart -- Diseases -- Case studies -- Periodicals
616.12 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/ehjcr/ ↗ - DOI:
- 10.1093/ehjcr/ytac491 ↗
- Languages:
- English
- ISSNs:
- 2514-2119
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25187.xml