Non Contrast-Enhanced MRA versus Ultrasound Blood Vessel Assessment to determine the Choice of Hemodialysis Vascular Access. Issue 4 (October 2013)
- Record Type:
- Journal Article
- Title:
- Non Contrast-Enhanced MRA versus Ultrasound Blood Vessel Assessment to determine the Choice of Hemodialysis Vascular Access. Issue 4 (October 2013)
- Main Title:
- Non Contrast-Enhanced MRA versus Ultrasound Blood Vessel Assessment to determine the Choice of Hemodialysis Vascular Access
- Authors:
- Merkx, Maarten A.G.
Bosboom, E. Mariëlle H.
Bode, Aron S.
Bescós, Javier Oliván
Breeuwer, Marcel
Tordoir, Jan H.M.
van de Vosse, Frans N. - Abstract:
- Purpose: The aim of this work was to establish the relationship between traditional blood vessel mapping for vascular access (VA) creation by B-mode ultrasound (US) and novel non contrast-enhanced magnetic resonance angiography (NCE-MRA), and to study the potential influence of the diameter assessment technique on the choice of hemodialysis vascular access. Methods: A total of 27 end-stage renal-disease patients were included. They received routine US and a NCE-MRA examination of the upper extremity. Diameters were measured manually on US and semi-automatically on NCE-MRA. These measurements were statistically compared for the arteries and veins and for each measurement location. Furthermore, sensitivity and specificity of both modalities to predict VA location was investigated by comparison with an experienced surgeon. This analysis gave insight into the potential influence of vessel mapping modality on decision-making. Results: Comparison of NCE-MRA with US for the arteries and veins, demonstrated a bias of 9% (limits −33%-78%) and 38% (limits −36%-198%), respectively. Statistically significant differences between the modalities on the individual locations were mainly found for the venous locations. The sensitivity and specificity for US to predict VA location was 1.0 and 0.74, respectively, while for NCE-MRA this was 0.88 and 0.39, respectively. Conclusions: The results obtained indicate that extreme caution should be exercised when replacing one diameter measurementPurpose: The aim of this work was to establish the relationship between traditional blood vessel mapping for vascular access (VA) creation by B-mode ultrasound (US) and novel non contrast-enhanced magnetic resonance angiography (NCE-MRA), and to study the potential influence of the diameter assessment technique on the choice of hemodialysis vascular access. Methods: A total of 27 end-stage renal-disease patients were included. They received routine US and a NCE-MRA examination of the upper extremity. Diameters were measured manually on US and semi-automatically on NCE-MRA. These measurements were statistically compared for the arteries and veins and for each measurement location. Furthermore, sensitivity and specificity of both modalities to predict VA location was investigated by comparison with an experienced surgeon. This analysis gave insight into the potential influence of vessel mapping modality on decision-making. Results: Comparison of NCE-MRA with US for the arteries and veins, demonstrated a bias of 9% (limits −33%-78%) and 38% (limits −36%-198%), respectively. Statistically significant differences between the modalities on the individual locations were mainly found for the venous locations. The sensitivity and specificity for US to predict VA location was 1.0 and 0.74, respectively, while for NCE-MRA this was 0.88 and 0.39, respectively. Conclusions: The results obtained indicate that extreme caution should be exercised when replacing one diameter measurement modality with the other. A further need exists to improve both vessel mapping protocols to obtain a geometric description of the upper extremity vasculature regardless of acquisition modality. … (more)
- Is Part Of:
- Journal of vascular access. Volume 14:Issue 4(2013)
- Journal:
- Journal of vascular access
- Issue:
- Volume 14:Issue 4(2013)
- Issue Display:
- Volume 14, Issue 4 (2013)
- Year:
- 2013
- Volume:
- 14
- Issue:
- 4
- Issue Sort Value:
- 2013-0014-0004-0000
- Page Start:
- 348
- Page End:
- 355
- Publication Date:
- 2013-10
- Subjects:
- Blood vessel mapping -- Comparison -- Dialysis arteriovenous fistula -- Duplex -- Magnetic resonance angiography -- Non contrast-enhanced -- Ultrasound
Arterial catheterization -- Periodicals
Intravenous catheterization -- Periodicals
612.13 - Journal URLs:
- http://journals.sagepub.com/home/jva ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.5301/jva.5000153 ↗
- Languages:
- English
- ISSNs:
- 1129-7298
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25189.xml