Shaking table substructure test of tuned liquid damper for controlling earthquake response of structure. Issue 12 (7th October 2022)
- Record Type:
- Journal Article
- Title:
- Shaking table substructure test of tuned liquid damper for controlling earthquake response of structure. Issue 12 (7th October 2022)
- Main Title:
- Shaking table substructure test of tuned liquid damper for controlling earthquake response of structure
- Authors:
- Xu, Guoshan
Zheng, Lichang
Bao, Yintong - Abstract:
- Abstract: For precisely disclosing the seismic performance of tuned liquid damper (TLD) vibration control structures, the shaking table substructure test (STST) method is presented and experimentally validated, and the parametric effects on the reduction efficiency of TLD are further investigated by using the STST method in this paper. Firstly, one optimal design method of TLD for high‐rise structures is presented. Secondly, the STST based on three variable control method (TVCM) for the TLD vibration control structures is presented. Thirdly, the effectiveness and robustness of the STST for TLD vibration control structures are validated by a series of tests on one three‐story‐frame structure with a rectangular TLD. Finally, the parametric effects on the reduction efficiency of TLD, in terms of mass ratio and liquid depth, are investigated using the STST method. Experimental results show that the displacement and acceleration responses of the STST match well with that of the traditional shaking table tests under El Centro (NS, 1940) and Taft earthquake wave record excitations, which indicates the effectiveness and the robustness of the STST based on TVCM for TLD vibration control structures. It is also shown from the experimental results that the best mass ratio and liquid depth are 4% and 40 mm, respectively, which are consistent with the optimal designs of TLD. Moreover, the control performance of TLD is not only related to its parameters but also related to the spectralAbstract: For precisely disclosing the seismic performance of tuned liquid damper (TLD) vibration control structures, the shaking table substructure test (STST) method is presented and experimentally validated, and the parametric effects on the reduction efficiency of TLD are further investigated by using the STST method in this paper. Firstly, one optimal design method of TLD for high‐rise structures is presented. Secondly, the STST based on three variable control method (TVCM) for the TLD vibration control structures is presented. Thirdly, the effectiveness and robustness of the STST for TLD vibration control structures are validated by a series of tests on one three‐story‐frame structure with a rectangular TLD. Finally, the parametric effects on the reduction efficiency of TLD, in terms of mass ratio and liquid depth, are investigated using the STST method. Experimental results show that the displacement and acceleration responses of the STST match well with that of the traditional shaking table tests under El Centro (NS, 1940) and Taft earthquake wave record excitations, which indicates the effectiveness and the robustness of the STST based on TVCM for TLD vibration control structures. It is also shown from the experimental results that the best mass ratio and liquid depth are 4% and 40 mm, respectively, which are consistent with the optimal designs of TLD. Moreover, the control performance of TLD is not only related to its parameters but also related to the spectral characteristics of ground motion excitations. … (more)
- Is Part Of:
- Structural control and health monitoring. Volume 29:Issue 12(2022)
- Journal:
- Structural control and health monitoring
- Issue:
- Volume 29:Issue 12(2022)
- Issue Display:
- Volume 29, Issue 12 (2022)
- Year:
- 2022
- Volume:
- 29
- Issue:
- 12
- Issue Sort Value:
- 2022-0029-0012-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-10-07
- Subjects:
- shaking table substructure test -- tuned liquid damper -- optimal design -- seismic performance -- vibration control
Structural engineering -- Periodicals
Structural control (Engineering) -- Periodicals
Automatic data collection systems -- Periodicals
Detectors -- Periodicals
624.17 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/stc.3122 ↗
- Languages:
- English
- ISSNs:
- 1545-2255
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8476.924000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25190.xml