Multi-laboratory inter-institute reproducibility study of IVOCT and IVUS assessments using published consensus document definitions. (15th September 2015)
- Record Type:
- Journal Article
- Title:
- Multi-laboratory inter-institute reproducibility study of IVOCT and IVUS assessments using published consensus document definitions. (15th September 2015)
- Main Title:
- Multi-laboratory inter-institute reproducibility study of IVOCT and IVUS assessments using published consensus document definitions
- Authors:
- Gerbaud, Edouard
Weisz, Giora
Tanaka, Atsushi
Kashiwagi, Manabu
Shimizu, Takehisa
Wang, Lin
Souza, Christiano
Bouma, Brett E.
Suter, Melissa J.
Shishkov, Milen
Ughi, Giovanni J.
Halpern, Elkan F.
Rosenberg, Mireille
Waxman, Sergio
Moses, Jeffrey W.
Mintz, Gary S.
Maehara, Akiko
Tearney, Guillermo J. - Abstract:
- Abstract: Aims: The aim of this study was to investigate the reproducibility of intravascular optical coherence tomography (IVOCT) assessments, including a comparison to intravascular ultrasound (IVUS). Intra-observer and inter-observer variabilities of IVOCT have been previously described, whereas inter-institute reliability in multiple laboratories has never been systematically studied. Methods and results: In 2 independent laboratories with intravascular imaging expertise, 100 randomized matched data sets of IVOCT and IVUS images were analysed by 4 independent observers according to published consensus document definitions. Intra-observer, inter-observer, and inter-institute variabilities of IVOCT qualitative and quantitative measurements vs. IVUS measurements were assessed. Minor inter- and intra-observer variability of both imaging techniques was observed for detailed qualitative and geometric analysis, except for inter-observer mixed plaque identification on IVUS ( κ = 0.70) and for inter-observer fibrous cap thickness measurement reproducibility on IVOCT (ICC = 0.48). The magnitude of inter-institute measurement differences for IVOCT was statistically significantly less than that for IVUS concerning lumen cross-sectional area (CSA), maximum and minimum lumen diameters, stent CSA, and maximum and minimum stent diameters ( P < 0.001, P < 0.001, P < 0.001, P = 0.02, P < 0.001, and P = 0.01, respectively). Minor inter-institute measurement variabilities using bothAbstract: Aims: The aim of this study was to investigate the reproducibility of intravascular optical coherence tomography (IVOCT) assessments, including a comparison to intravascular ultrasound (IVUS). Intra-observer and inter-observer variabilities of IVOCT have been previously described, whereas inter-institute reliability in multiple laboratories has never been systematically studied. Methods and results: In 2 independent laboratories with intravascular imaging expertise, 100 randomized matched data sets of IVOCT and IVUS images were analysed by 4 independent observers according to published consensus document definitions. Intra-observer, inter-observer, and inter-institute variabilities of IVOCT qualitative and quantitative measurements vs. IVUS measurements were assessed. Minor inter- and intra-observer variability of both imaging techniques was observed for detailed qualitative and geometric analysis, except for inter-observer mixed plaque identification on IVUS ( κ = 0.70) and for inter-observer fibrous cap thickness measurement reproducibility on IVOCT (ICC = 0.48). The magnitude of inter-institute measurement differences for IVOCT was statistically significantly less than that for IVUS concerning lumen cross-sectional area (CSA), maximum and minimum lumen diameters, stent CSA, and maximum and minimum stent diameters ( P < 0.001, P < 0.001, P < 0.001, P = 0.02, P < 0.001, and P = 0.01, respectively). Minor inter-institute measurement variabilities using both techniques were also found for plaque identification. Conclusion: In the measurement of lumen CSA, maximum and minimum lumen diameters, stent CSA, and maximum and minimum stent diameters by analysts from two different laboratories, reproducibility of IVOCT was more consistent than that of IVUS. … (more)
- Is Part Of:
- European heart journal. Volume 17:Number 7(2016:Jul.)
- Journal:
- European heart journal
- Issue:
- Volume 17:Number 7(2016:Jul.)
- Issue Display:
- Volume 17, Issue 7 (2016)
- Year:
- 2016
- Volume:
- 17
- Issue:
- 7
- Issue Sort Value:
- 2016-0017-0007-0000
- Page Start:
- 756
- Page End:
- 764
- Publication Date:
- 2015-09-15
- Subjects:
- Reproducibility -- Intravascular ultrasound imaging -- Optical frequency domain imaging -- Optical coherence tomography
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.10754 - Journal URLs:
- http://ehjcimaging.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/jev229 ↗
- Languages:
- English
- ISSNs:
- 2047-2404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25190.xml