1879. Detection of COVID-19 Outbreaks in Long-Term Care Homes Using Built Environment Testing for SARS-CoV-2: A Multicentre Prospective Study. (15th December 2022)
- Record Type:
- Journal Article
- Title:
- 1879. Detection of COVID-19 Outbreaks in Long-Term Care Homes Using Built Environment Testing for SARS-CoV-2: A Multicentre Prospective Study. (15th December 2022)
- Main Title:
- 1879. Detection of COVID-19 Outbreaks in Long-Term Care Homes Using Built Environment Testing for SARS-CoV-2: A Multicentre Prospective Study
- Authors:
- Fralick, Michael
Moggridge, Jason
Castellani, Lucas
Donaldson, Sylva
Guttman, David S
Hinz, Aaron
Hug, Laura
Manuel, Doug
McGeer, Allison
Mejbel, Hebah
Nott, Caroline
Raudanskis, Ashley
Thampi, Nisha
Wong, Alex
Zanichelli, Veronica
Kassen, Rees
Macfadden, Derek - Abstract:
- Abstract: Background: Environmental surveillance of SARS-CoV-2 via wastewater has become an invaluable tool for population-level surveillance of COVID-19. More highly resolved environmental sampling approaches may also be useful for surveillance. Built environment sampling may provide a spatially refined approach for surveillance of COVID-19 in congregate living settings. Methods: We conducted a prospective study of 10 long-term care homes (LTCHs) in both urban and rural settings in Ontario Canada between September 2021 and April 2022. Floor surfaces were sampled weekly at multiple locations within each building and were analyzed for the presence of SARS-CoV-2 using qPCR. The exposure variable was detection of SARS-CoV-2 on floors. The primary outcome was the presence of a COVID-19 outbreak. We calculated the test characteristics of the presence of SARS-CoV-2 on floors for detection of COVID-19 outbreaks. Results: We followed 10 LTCHs for 214 cumulative weeks, and collected 3, 219 swabs from 183 unique locations. Overall, 15 COVID-19 outbreaks occurred with 74.9 cumulative weeks of outbreaks. During time periods when there were outbreaks of COVID-19 the proportion of floor swabs positive for SaRS-CoV-2 was 50.8% (95% CI: 47.7-53.9). During time periods where there were no outbreaks of COVID-19 the proportion of floor swabs positive was 15.8% (95% CI:14.3-17.3). Using the proportion of positive floor swabs for SARS-CoV-2 to predict COVID-19 outbreak status for a given week,Abstract: Background: Environmental surveillance of SARS-CoV-2 via wastewater has become an invaluable tool for population-level surveillance of COVID-19. More highly resolved environmental sampling approaches may also be useful for surveillance. Built environment sampling may provide a spatially refined approach for surveillance of COVID-19 in congregate living settings. Methods: We conducted a prospective study of 10 long-term care homes (LTCHs) in both urban and rural settings in Ontario Canada between September 2021 and April 2022. Floor surfaces were sampled weekly at multiple locations within each building and were analyzed for the presence of SARS-CoV-2 using qPCR. The exposure variable was detection of SARS-CoV-2 on floors. The primary outcome was the presence of a COVID-19 outbreak. We calculated the test characteristics of the presence of SARS-CoV-2 on floors for detection of COVID-19 outbreaks. Results: We followed 10 LTCHs for 214 cumulative weeks, and collected 3, 219 swabs from 183 unique locations. Overall, 15 COVID-19 outbreaks occurred with 74.9 cumulative weeks of outbreaks. During time periods when there were outbreaks of COVID-19 the proportion of floor swabs positive for SaRS-CoV-2 was 50.8% (95% CI: 47.7-53.9). During time periods where there were no outbreaks of COVID-19 the proportion of floor swabs positive was 15.8% (95% CI:14.3-17.3). Using the proportion of positive floor swabs for SARS-CoV-2 to predict COVID-19 outbreak status for a given week, the area under the receiver operating curve was 0.84 (95% CI: 0.76-0.92). Using thresholds of ≥10%, ≥30%, and ≥50%, the prevalence of floor swabs positive for SARS-CoV-2 yielded positive predictive values for outbreak of 0.52 (0.43-0.61), 0.65 (0.53-0.75), and 0.72 (0.58-0.83) respectively, and negative predictive values of 0.93 (0.86-0.97), 0.85 (0.78-0.91), and 0.80 (0.73-0.86) respectively (Figure 1). 13 outbreaks had floor sampling performed in the week prior to them being identified, and of these 7 (54%) had positive swab proportions exceeding 30% in the week prior to the outbreak. Figure 1. Test characteristics of built environment floor swabs for predicting COVID-19 outbreaks in LTCH. Figure 1. Test characteristics of different thresholds for percentage of floor swabs positive for SARS-CoV-2 at a given LTCH for predicting active COVID-19 outbreak in the same building in the same week. NPV = negative predictive value, PPV = positive predictive value, Sens = sensitivity, Spec = specificity. Conclusion: Detection of SARS-CoV-2 on floors is strongly associated with COVID-19 outbreaks in LTCHs. These data suggest a potential role for floor sampling in improving early outbreak detection and management. Disclosures: Michael Fralick, MD, ProofDx: Advisor/Consultant Doug Manuel, MD, PhD, World Bank: Advisor/Consultant. … (more)
- Is Part Of:
- Open forum infectious diseases. Volume 9:(2022)Supplement 2
- Journal:
- Open forum infectious diseases
- Issue:
- Volume 9:(2022)Supplement 2
- Issue Display:
- Volume 9, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 9
- Issue:
- 2
- Issue Sort Value:
- 2022-0009-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-12-15
- Subjects:
- Communicable diseases -- Periodicals
Medical microbiology -- Periodicals
Infection -- Periodicals
616.9 - Journal URLs:
- http://ofid.oxfordjournals.org/ ↗
http://www.oxfordjournals.org/en/ ↗ - DOI:
- 10.1093/ofid/ofac492.1506 ↗
- Languages:
- English
- ISSNs:
- 2328-8957
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25195.xml