Analysis of fault current and overvoltage at the neutral point of ±800 kV High-Voltage DC converter transformer. (November 2022)
- Record Type:
- Journal Article
- Title:
- Analysis of fault current and overvoltage at the neutral point of ±800 kV High-Voltage DC converter transformer. (November 2022)
- Main Title:
- Analysis of fault current and overvoltage at the neutral point of ±800 kV High-Voltage DC converter transformer
- Authors:
- Fu, Jiaqing
Han, Yang
Yang, Ping
Wang, Congling
Zalhaf, Amr S. - Abstract:
- Abstract: In order to enhance the security of ± 800 kV High-Voltage DC (HVDC) system, it is needed to consider and analyze the grounding mode of the neutral point of converter transformer. Different neutral grounding modes have different inhibitory effects on the current of transmission lines when faults occur, and also produce different overvoltages at the neutral point. Therefore, this paper first analyzes the influence of converter transformer on fault current and neutral point voltage in three cases of ungrounded, direct grounding and via small reactance grounding. Through the analysis, it is known that the neutral grounding via small reactance is the most suitable for the HVDC transmission system. Then the model of ± 800 kV bipolar HVDC transmission system is built in PSCAD/ EMTDC simulation software and analyzed under two typical conditions of grounding overvoltage and breaking overvoltage. By comparing several cases of converter transformer neutral point grounding directly, via 5 Ω, 10 Ω, 17 Ω, 20 Ω and 25 Ω reactance grounding, it is found that grounding via small reactance can effectively suppress fault current. However, with the increase of the resistance value, the inhibitory effect will gradually weaken and cause the increase of the neutral point overvoltage.
- Is Part Of:
- Energy reports. Volume 8(2022)Supplement 10
- Journal:
- Energy reports
- Issue:
- Volume 8(2022)Supplement 10
- Issue Display:
- Volume 8, Issue 10 (2022)
- Year:
- 2022
- Volume:
- 8
- Issue:
- 10
- Issue Sort Value:
- 2022-0008-0010-0000
- Page Start:
- 292
- Page End:
- 300
- Publication Date:
- 2022-11
- Subjects:
- HVDC -- Converter transformers -- Neutral point -- Grounding overvoltage -- Fault current
Power resources -- Periodicals
Energy industries -- Periodicals
Power resources
Periodicals
Electronic journals
621.04205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23524847/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.egyr.2022.05.195 ↗
- Languages:
- English
- ISSNs:
- 2352-4847
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25166.xml