Optimization of mesh generation for geometric accuracy, robustness, and efficiency of biomechanical‐model‐based deformable image registration. Issue 1 (24th August 2022)
- Record Type:
- Journal Article
- Title:
- Optimization of mesh generation for geometric accuracy, robustness, and efficiency of biomechanical‐model‐based deformable image registration. Issue 1 (24th August 2022)
- Main Title:
- Optimization of mesh generation for geometric accuracy, robustness, and efficiency of biomechanical‐model‐based deformable image registration
- Authors:
- He, Yulun
Anderson, Brian M.
Cazoulat, Guillaume
Rigaud, Bastien
Almodovar‐Abreu, Lusmeralis
Pollard‐Larkin, Julianne
Balter, Peter
Liao, Zhongxing
Mohan, Radhe
Odisio, Bruno
Svensson, Stina
Brock, Kristy K. - Abstract:
- Abstract: Background: Successful generation of biomechanical‐model‐based deformable image registration (BM‐DIR) relies on user‐defined parameters that dictate surface mesh quality. The trial‐and‐error process to determine the optimal parameters can be labor‐intensive and hinder DIR efficiency and clinical workflow. Purpose: To identify optimal parameters in surface mesh generation as boundary conditions for a BM‐DIR in longitudinal liver and lung CT images to facilitate streamlined image registration processes. Methods: Contrast‐enhanced CT images of 29 colorectal liver cancer patients and end‐exhale four‐dimensional CT images of 26 locally advanced non‐small cell lung cancer patients were collected. Different combinations of parameters that determine the triangle mesh quality (voxel side length and triangle edge length) were investigated. The quality of DIRs generated using these parameters was evaluated with metrics for geometric accuracy, robustness, and efficiency. Metrics for geometric accuracy included target registration error (TRE) of internal vessel bifurcations, dice similar coefficient (DSC), mean distance to agreement (MDA), Hausdorff distance (HD) for organ contours, and number of vertices in the triangle mesh. American Association of Physicists in Medicine Task Group 132 was used to ensure parameters met TRE, DSC, MDA recommendations before the comparison among the parameters. Robustness was evaluated as the success rate of DIR generation, and efficiency wasAbstract: Background: Successful generation of biomechanical‐model‐based deformable image registration (BM‐DIR) relies on user‐defined parameters that dictate surface mesh quality. The trial‐and‐error process to determine the optimal parameters can be labor‐intensive and hinder DIR efficiency and clinical workflow. Purpose: To identify optimal parameters in surface mesh generation as boundary conditions for a BM‐DIR in longitudinal liver and lung CT images to facilitate streamlined image registration processes. Methods: Contrast‐enhanced CT images of 29 colorectal liver cancer patients and end‐exhale four‐dimensional CT images of 26 locally advanced non‐small cell lung cancer patients were collected. Different combinations of parameters that determine the triangle mesh quality (voxel side length and triangle edge length) were investigated. The quality of DIRs generated using these parameters was evaluated with metrics for geometric accuracy, robustness, and efficiency. Metrics for geometric accuracy included target registration error (TRE) of internal vessel bifurcations, dice similar coefficient (DSC), mean distance to agreement (MDA), Hausdorff distance (HD) for organ contours, and number of vertices in the triangle mesh. American Association of Physicists in Medicine Task Group 132 was used to ensure parameters met TRE, DSC, MDA recommendations before the comparison among the parameters. Robustness was evaluated as the success rate of DIR generation, and efficiency was evaluated as the total time to generate boundary conditions and compute finite element analysis. Results: Voxel side length of 0.2 cm and triangle edge length of 3 were found to be the optimal parameters for both liver and lung, with success rate of 1.00 and 0.98 and average DIR computation time of 100 and 143 s, respectively. For this combination, the average TRE, DSC, MDA, and HD were 0.38–0.40, 0.96–0.97, 0.09–0.12, and 0.87–1.17 mm, respectively. Conclusion: The optimal parameters were found for the analyzed patients. The decision‐making process described in this study serves as a recommendation for BM‐DIR algorithms to be used for liver and lung. These parameters can facilitate consistence in the evaluation of published studies and more widespread utilization of BM‐DIR in clinical practice. … (more)
- Is Part Of:
- Medical physics. Volume 50:Issue 1(2023)
- Journal:
- Medical physics
- Issue:
- Volume 50:Issue 1(2023)
- Issue Display:
- Volume 50, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 50
- Issue:
- 1
- Issue Sort Value:
- 2023-0050-0001-0000
- Page Start:
- 323
- Page End:
- 329
- Publication Date:
- 2022-08-24
- Subjects:
- biomechanical‐model‐based image registration -- deformable image registration -- optimization
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.15939 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25181.xml