A Comparison of Laser‐Protected Endotracheal Tubes. (21st August 2018)
- Record Type:
- Journal Article
- Title:
- A Comparison of Laser‐Protected Endotracheal Tubes. (21st August 2018)
- Main Title:
- A Comparison of Laser‐Protected Endotracheal Tubes
- Authors:
- Burns, James A.
Adlard, Stephen D.
Kobler, James B.
Tynan, Monica A.
Petrillo, Robert H.
Tracy, Lauren F. - Abstract:
- Abstract : Objectives: To compare the physical characteristics of 3 laser‐protected endotracheal tubes (LPETs) commonly used in endoscopic laser surgery. To report potential intraoperative problems related to LPET use and suggest practical solutions. Study Design: Comparative analysis. Setting: Academic laboratory. Subjects and Methods: Physical characteristics of the Mallinckrodt Laser‐Flex (MTL), Medtronic Laser‐Shield II (ML‐II), and Rusch LaserTubus (RL) were compared. The effect of bending LPETs on airflow resistance was estimated with a pressure transducer. The force required to pull each tube through the glottis and the pressure exerted during this maneuver were measured in a fresh cadaveric human larynx. Results: The design features and physical characteristics of LPETs differ, including varying balloon‐tip lengths. Bending LPETs to acute angles caused significant pressure increase within the RL tube (Δ 3.42 cm H2 O) and minimal change within the ML‐II (Δ 0.12 cm H2 O) and MTL (Δ 0.21 cm H2 O) tubes. The average force required to pull the RL (48.12 g, P =. 003) and MTL (282.4 g, P =. 001) tubes through the glottis was 7.6× and 44.5× greater than that for the ML‐II (6.39 g). When pulled through the vocal folds, the ML‐II cuff exerted no detectable pressure, whereas higher pressures were measured for the RL (2.2 cm H2 O) and MTL (6.5 cm H2 O) tubes. Conclusion: The ML‐II tube had the most favorable characteristics, with minimal pressure during extubation and resistanceAbstract : Objectives: To compare the physical characteristics of 3 laser‐protected endotracheal tubes (LPETs) commonly used in endoscopic laser surgery. To report potential intraoperative problems related to LPET use and suggest practical solutions. Study Design: Comparative analysis. Setting: Academic laboratory. Subjects and Methods: Physical characteristics of the Mallinckrodt Laser‐Flex (MTL), Medtronic Laser‐Shield II (ML‐II), and Rusch LaserTubus (RL) were compared. The effect of bending LPETs on airflow resistance was estimated with a pressure transducer. The force required to pull each tube through the glottis and the pressure exerted during this maneuver were measured in a fresh cadaveric human larynx. Results: The design features and physical characteristics of LPETs differ, including varying balloon‐tip lengths. Bending LPETs to acute angles caused significant pressure increase within the RL tube (Δ 3.42 cm H2 O) and minimal change within the ML‐II (Δ 0.12 cm H2 O) and MTL (Δ 0.21 cm H2 O) tubes. The average force required to pull the RL (48.12 g, P =. 003) and MTL (282.4 g, P =. 001) tubes through the glottis was 7.6× and 44.5× greater than that for the ML‐II (6.39 g). When pulled through the vocal folds, the ML‐II cuff exerted no detectable pressure, whereas higher pressures were measured for the RL (2.2 cm H2 O) and MTL (6.5 cm H2 O) tubes. Conclusion: The ML‐II tube had the most favorable characteristics, with minimal pressure during extubation and resistance to kinking. The RL tube kinks readily with a resultant increase in resistance to airflow. The MTL tube extends farther into the trachea due to a relatively elongated balloon‐tip configuration. Future LPET designs should incorporate features that avoid intraoperative difficulties related to airway protection and ventilation. … (more)
- Is Part Of:
- Otolaryngology--head and neck surgery. Volume 159:Number 5(2018)
- Journal:
- Otolaryngology--head and neck surgery
- Issue:
- Volume 159:Number 5(2018)
- Issue Display:
- Volume 159, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 159
- Issue:
- 5
- Issue Sort Value:
- 2018-0159-0005-0000
- Page Start:
- 871
- Page End:
- 878
- Publication Date:
- 2018-08-21
- Subjects:
- laser -- endotracheal tube -- intubation -- endoscopic laryngeal laser surgery -- transoral laser surgery
Head -- Surgery -- Periodicals
Neck -- Surgery -- Periodicals
Otolaryngology -- Periodicals
617.51 - Journal URLs:
- http://oto.sagepub.com/content/by/year ↗
http://online.sagepub.com/ ↗
http://www.mosby.com/oto ↗
http://www.sciencedirect.com/science/journal/01945998 ↗ - DOI:
- 10.1177/0194599818796106 ↗
- Languages:
- English
- ISSNs:
- 0194-5998
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6313.523000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25173.xml