Intracochlear Pressure Changes due to 2 Electrode Types: An Artificial Model Experiment. (27th December 2016)
- Record Type:
- Journal Article
- Title:
- Intracochlear Pressure Changes due to 2 Electrode Types: An Artificial Model Experiment. (27th December 2016)
- Main Title:
- Intracochlear Pressure Changes due to 2 Electrode Types: An Artificial Model Experiment
- Authors:
- Mittmann, Philipp
Mittmann, Marlene
Ernst, Arneborg
Todt, Ingo - Abstract:
- Abstract : Objective: To preserve residual hearing in cochlear implant surgery, the electrode design has been refined, and an atraumatic insertion has become one aspect of cochlear implant research. Previous studies have described the effect of insertion speed and opening of the round window membrane on intracochlear pressure changes. The aim of our current study was to observe intracochlear pressure changes due to different cochlear implant electrodes in an artificial cochlear model with stable surrounding factors. Study Design: Prospective controlled study. Setting: Tertiary referral center. Subjects and Methods: The experiments were performed in an artificial cochlear model with a pressure sensor in the apical area. With straight and perimodiolar electrode arrays, 5 insertions with the same insertion speed and 5 insertions over the same time were performed. Results: With the perimodiolar high‐volume electrode, significantly greater intracochlear fluid pressure changes were observed than with the straight electrode. Compared with the straight electrode, the perimodiolar electrode induces significantly higher pressure peaks (1.12 ± 0.15 vs 0.86 ± 0.05 mm Hg, P =. 006) and significantly higher amplitudes (0.38 ± 0.07 vs 0.09 ± 0.07 mm Hg, P <. 001). Conclusion: The reliable preservation of residual hearing is an important multifactorial challenge in modern cochlear implant surgery. Insertion speed, handling, and electrode design are known to influence the preservation ofAbstract : Objective: To preserve residual hearing in cochlear implant surgery, the electrode design has been refined, and an atraumatic insertion has become one aspect of cochlear implant research. Previous studies have described the effect of insertion speed and opening of the round window membrane on intracochlear pressure changes. The aim of our current study was to observe intracochlear pressure changes due to different cochlear implant electrodes in an artificial cochlear model with stable surrounding factors. Study Design: Prospective controlled study. Setting: Tertiary referral center. Subjects and Methods: The experiments were performed in an artificial cochlear model with a pressure sensor in the apical area. With straight and perimodiolar electrode arrays, 5 insertions with the same insertion speed and 5 insertions over the same time were performed. Results: With the perimodiolar high‐volume electrode, significantly greater intracochlear fluid pressure changes were observed than with the straight electrode. Compared with the straight electrode, the perimodiolar electrode induces significantly higher pressure peaks (1.12 ± 0.15 vs 0.86 ± 0.05 mm Hg, P =. 006) and significantly higher amplitudes (0.38 ± 0.07 vs 0.09 ± 0.07 mm Hg, P <. 001). Conclusion: The reliable preservation of residual hearing is an important multifactorial challenge in modern cochlear implant surgery. Insertion speed, handling, and electrode design are known to influence the preservation of residual hearing. In our artificial model experiments, we could prove objectively that the volume of the electrodes has a significant influence on the intracochlear pressure changes during cochlear implantation. … (more)
- Is Part Of:
- Otolaryngology--head and neck surgery. Volume 156:Number 4(2017)
- Journal:
- Otolaryngology--head and neck surgery
- Issue:
- Volume 156:Number 4(2017)
- Issue Display:
- Volume 156, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 156
- Issue:
- 4
- Issue Sort Value:
- 2017-0156-0004-0000
- Page Start:
- 712
- Page End:
- 716
- Publication Date:
- 2016-12-27
- Subjects:
- CI electrode volume -- intracochlear fluid pressure -- hearing preservation
Head -- Surgery -- Periodicals
Neck -- Surgery -- Periodicals
Otolaryngology -- Periodicals
617.51 - Journal URLs:
- http://oto.sagepub.com/content/by/year ↗
http://online.sagepub.com/ ↗
http://www.mosby.com/oto ↗
http://www.sciencedirect.com/science/journal/01945998 ↗ - DOI:
- 10.1177/0194599816684104 ↗
- Languages:
- English
- ISSNs:
- 0194-5998
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6313.523000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25178.xml