A component method to delineate surgical spine implants for proton Monte Carlo dose calculation. Issue 1 (9th October 2022)
- Record Type:
- Journal Article
- Title:
- A component method to delineate surgical spine implants for proton Monte Carlo dose calculation. Issue 1 (9th October 2022)
- Main Title:
- A component method to delineate surgical spine implants for proton Monte Carlo dose calculation
- Authors:
- Chang, Chih‐Wei
Charyyev, Serdar
Harms, Joseph
Slopsema, Roelf
Wolf, Jonathan
Refai, Daniel
Yoon, Tim
McDonald, Mark W.
Bradley, Jeffrey D.
Leng, Shuai
Zhou, Jun
Yang, Xiaofeng
Lin, Liyong - Abstract:
- Abstract: Purpose: Metallic implants have been correlated to local control failure for spinal sarcoma and chordoma patients due to the uncertainty of implant delineation from computed tomography (CT). Such uncertainty can compromise the proton Monte Carlo dose calculation (MCDC) accuracy. A component method is proposed to determine the dimension and volume of the implants from CT images. Methods: The proposed component method leverages the knowledge of surgical implants from medical supply vendors to predefine accurate contours for each implant component, including tulips, screw bodies, lockers, and rods. A retrospective patient study was conducted to demonstrate the feasibility of the method. The reference implant materials and samples were collected from patient medical records and vendors, Medtronic and NuVasive. Additional CT images with extensive features, such as extended Hounsfield units and various reconstruction diameters, were used to quantify the uncertainty of implant contours. Results: For in vivo patient implant estimation, the reference and the component method differences were 0.35, 0.17, and 0.04 cm 3 for tulips, screw bodies, and rods, respectively. The discrepancies by a conventional threshold method were 5.46, 0.76, and 0.05 cm 3, respectively. The mischaracterization of implant materials and dimensions can underdose the clinical target volume coverage by 20 cm 3 for a patient with eight lumbar implants. The tulip dominates the dosimetry uncertainty as itAbstract: Purpose: Metallic implants have been correlated to local control failure for spinal sarcoma and chordoma patients due to the uncertainty of implant delineation from computed tomography (CT). Such uncertainty can compromise the proton Monte Carlo dose calculation (MCDC) accuracy. A component method is proposed to determine the dimension and volume of the implants from CT images. Methods: The proposed component method leverages the knowledge of surgical implants from medical supply vendors to predefine accurate contours for each implant component, including tulips, screw bodies, lockers, and rods. A retrospective patient study was conducted to demonstrate the feasibility of the method. The reference implant materials and samples were collected from patient medical records and vendors, Medtronic and NuVasive. Additional CT images with extensive features, such as extended Hounsfield units and various reconstruction diameters, were used to quantify the uncertainty of implant contours. Results: For in vivo patient implant estimation, the reference and the component method differences were 0.35, 0.17, and 0.04 cm 3 for tulips, screw bodies, and rods, respectively. The discrepancies by a conventional threshold method were 5.46, 0.76, and 0.05 cm 3, respectively. The mischaracterization of implant materials and dimensions can underdose the clinical target volume coverage by 20 cm 3 for a patient with eight lumbar implants. The tulip dominates the dosimetry uncertainty as it can be made from titanium or cobalt–chromium alloys by different vendors. Conclusions: A component method was developed and demonstrated using phantom and patient studies with implants. The proposed method provides more accurate implant characterization for proton MCDC and can potentially enhance the treatment quality for proton therapy. The current proof‐of‐concept study is limited to the implant characterization for lumbar spine. Future investigations could be extended to cervical spine and dental implants for head‐and‐neck patients where tight margins are required to spare organs at risk. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 24:Issue 1(2023)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 24:Issue 1(2023)
- Issue Display:
- Volume 24, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 24
- Issue:
- 1
- Issue Sort Value:
- 2023-0024-0001-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-10-09
- Subjects:
- Monte Carlo dose calculation -- proton therapy -- surgical implant delineation
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13800 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25149.xml