Efficacy of Perioperative Lumbar Drainage following Endonasal Endoscopic Cerebrospinal Fluid Leak Repair: A Meta‐analysis. (3rd October 2016)
- Record Type:
- Journal Article
- Title:
- Efficacy of Perioperative Lumbar Drainage following Endonasal Endoscopic Cerebrospinal Fluid Leak Repair: A Meta‐analysis. (3rd October 2016)
- Main Title:
- Efficacy of Perioperative Lumbar Drainage following Endonasal Endoscopic Cerebrospinal Fluid Leak Repair: A Meta‐analysis
- Authors:
- Ahmed, Omar H.
Marcus, Sonya
Tauber, Jenna R.
Wang, Binhuan
Fang, Yixin
Lebowitz, Richard A. - Abstract:
- Abstract : Objective: Perioperative lumbar drain (LD) use in the setting of endoscopic cerebrospinal fluid (CSF) leak repair is a well‐established practice. However, recent data suggest that LDs may not provide significant benefit and may thus confer unnecessary risk. To examine this, we conducted a meta‐analysis to investigate the effect of LDs on postoperative CSF leak recurrence following endoscopic repair of CSF rhinorrhea. Data Sources: A comprehensive search was performed with the following databases: Ovid MEDLINE (1947 to November 2015), EMBASE (1974 to November 2015), Cochrane Review, and PubMed (1990 to November 2015). Review Method: A meta‐analysis was performed according to PRISMA guidelines. Results: A total of 1314 nonduplicate studies were identified in our search. Twelve articles comprising 508 cases met inclusion criteria. Overall, use of LDs was not associated with significantly lower postoperative CSF leak recurrence rates following endoscopic repair of CSF rhinorrhea (odds ratio: 0.89, 95% confidence interval: 0.40‐1.95) as compared with cases performed without LDs. Subgroup analysis of only CSF leaks associated with anterior skull base resections (6 studies, 153 cases) also demonstrated that lumbar drainage did not significantly affect rates of successful repair (odds ratio: 2.67, 95% confidence interval: 0.64‐11.10). Conclusions: There is insufficient evidence to support that adjunctive lumbar drainage significantly reduces postoperative CSF leakAbstract : Objective: Perioperative lumbar drain (LD) use in the setting of endoscopic cerebrospinal fluid (CSF) leak repair is a well‐established practice. However, recent data suggest that LDs may not provide significant benefit and may thus confer unnecessary risk. To examine this, we conducted a meta‐analysis to investigate the effect of LDs on postoperative CSF leak recurrence following endoscopic repair of CSF rhinorrhea. Data Sources: A comprehensive search was performed with the following databases: Ovid MEDLINE (1947 to November 2015), EMBASE (1974 to November 2015), Cochrane Review, and PubMed (1990 to November 2015). Review Method: A meta‐analysis was performed according to PRISMA guidelines. Results: A total of 1314 nonduplicate studies were identified in our search. Twelve articles comprising 508 cases met inclusion criteria. Overall, use of LDs was not associated with significantly lower postoperative CSF leak recurrence rates following endoscopic repair of CSF rhinorrhea (odds ratio: 0.89, 95% confidence interval: 0.40‐1.95) as compared with cases performed without LDs. Subgroup analysis of only CSF leaks associated with anterior skull base resections (6 studies, 153 cases) also demonstrated that lumbar drainage did not significantly affect rates of successful repair (odds ratio: 2.67, 95% confidence interval: 0.64‐11.10). Conclusions: There is insufficient evidence to support that adjunctive lumbar drainage significantly reduces postoperative CSF leak recurrence in patients undergoing endoscopic CSF leak repair. Subgroup analysis examining only those patients whose CSF leaks were associated with anterior skull base resections demonstrated similar results. More level 1 and 2 studies are needed to further investigate the efficacy of LDs, particularly in the setting of patients at high risk for CSF leak recurrence. … (more)
- Is Part Of:
- Otolaryngology--head and neck surgery. Volume 156:Number 1(2017)
- Journal:
- Otolaryngology--head and neck surgery
- Issue:
- Volume 156:Number 1(2017)
- Issue Display:
- Volume 156, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 156
- Issue:
- 1
- Issue Sort Value:
- 2017-0156-0001-0000
- Page Start:
- 52
- Page End:
- 60
- Publication Date:
- 2016-10-03
- Subjects:
- cerebrospinal fluid leak -- cerebrospinal fluid rhinorrhea -- lumbar drains -- cerebrospinal fluid diversion -- endoscopic skull base surgery
Head -- Surgery -- Periodicals
Neck -- Surgery -- Periodicals
Otolaryngology -- Periodicals
617.51 - Journal URLs:
- http://oto.sagepub.com/content/by/year ↗
http://online.sagepub.com/ ↗
http://www.mosby.com/oto ↗
http://www.sciencedirect.com/science/journal/01945998 ↗ - DOI:
- 10.1177/0194599816670370 ↗
- Languages:
- English
- ISSNs:
- 0194-5998
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6313.523000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25154.xml