Effectiveness of embolic protection filter devices in stroke prevention during endovascular aortic arch repair in significant aortic atheroma patients. (31st January 2019)
- Record Type:
- Journal Article
- Title:
- Effectiveness of embolic protection filter devices in stroke prevention during endovascular aortic arch repair in significant aortic atheroma patients. (31st January 2019)
- Main Title:
- Effectiveness of embolic protection filter devices in stroke prevention during endovascular aortic arch repair in significant aortic atheroma patients
- Authors:
- Shimamura, Kazuo
Kuratani, Toru
Kin, Keiwa
Shijo, Takayuki
Masada, Kenta
Sawa, Yoshiki - Abstract:
- Abstract: OBJECTIVES: The objective of this study was to evaluate the effectiveness of embolic protection filter device in stroke prevention during hybrid endovascular arch repair in patients with significant aortic atheroma. METHODS: Twenty-two patients (20 men, mean age 79.0 years, mean logistic EuroSCORE 23.9%) with aortic arch/proximal descending aortic diseases and significant aortic atheroma (atheroma grade ≥ II) who were deemed unfit for conventional open surgery underwent endovascular aortic arch repair with protection of the supra-arch vessels using a balloon catheter and filter devices. The effectiveness in preventing stroke was evaluated by a postoperative neurological examination protocol, which was followed by neuroimaging with computed tomography/DW-magnetic resonance imaging (MRI) study in cases with neurological deficits. RESULTS: The atheroma grades of the aortic arch were II, III and IV in 36%, 14% and 50% of the patients, respectively. In total, 37 filter devices were placed in the supra-aortic vessels (5 brachiocephalic arteries, 23 carotid arteries, 5 subclavian arteries and 4 vertebral arteries). Technical success was achieved in all patients, and 30-day mortality was 4.5% (1/22 cases). Two (9.1%) cases showed neurological symptomatic stroke postoperatively. With DW-MRI examination, a major new region was detected in the filter-protected left carotid artery in one case and in the balloon-protected left vertebral artery in another case. CONCLUSIONS: InAbstract: OBJECTIVES: The objective of this study was to evaluate the effectiveness of embolic protection filter device in stroke prevention during hybrid endovascular arch repair in patients with significant aortic atheroma. METHODS: Twenty-two patients (20 men, mean age 79.0 years, mean logistic EuroSCORE 23.9%) with aortic arch/proximal descending aortic diseases and significant aortic atheroma (atheroma grade ≥ II) who were deemed unfit for conventional open surgery underwent endovascular aortic arch repair with protection of the supra-arch vessels using a balloon catheter and filter devices. The effectiveness in preventing stroke was evaluated by a postoperative neurological examination protocol, which was followed by neuroimaging with computed tomography/DW-magnetic resonance imaging (MRI) study in cases with neurological deficits. RESULTS: The atheroma grades of the aortic arch were II, III and IV in 36%, 14% and 50% of the patients, respectively. In total, 37 filter devices were placed in the supra-aortic vessels (5 brachiocephalic arteries, 23 carotid arteries, 5 subclavian arteries and 4 vertebral arteries). Technical success was achieved in all patients, and 30-day mortality was 4.5% (1/22 cases). Two (9.1%) cases showed neurological symptomatic stroke postoperatively. With DW-MRI examination, a major new region was detected in the filter-protected left carotid artery in one case and in the balloon-protected left vertebral artery in another case. CONCLUSIONS: In high-risk patients with significant aortic arch atheroma, hybrid endovascular aortic arch repair with embolic protection using a filter device showed satisfactory early results. Filter protection could be an attractive adjunct manoeuvre for preventing critical stroke during endovascular arch repair. … (more)
- Is Part Of:
- Interactive cardiovascular and thoracic surgery. Volume 28:Number 6(2019)
- Journal:
- Interactive cardiovascular and thoracic surgery
- Issue:
- Volume 28:Number 6(2019)
- Issue Display:
- Volume 28, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 28
- Issue:
- 6
- Issue Sort Value:
- 2019-0028-0006-0000
- Page Start:
- 974
- Page End:
- 980
- Publication Date:
- 2019-01-31
- Subjects:
- Hybrid aortic arch repair -- Filter protection -- Stroke
Chest -- Surgery -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
616.1 - Journal URLs:
- http://icvts.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/icvts/ivz004 ↗
- Languages:
- English
- ISSNs:
- 1569-9293
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4531.871920
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25150.xml