Comparison of patient-specific internal gross tumor volume for radiation treatment of primary esophageal cancer based separately on three-dimensional and four-dimensional computed tomography images. Issue 4 (1st June 2014)
- Record Type:
- Journal Article
- Title:
- Comparison of patient-specific internal gross tumor volume for radiation treatment of primary esophageal cancer based separately on three-dimensional and four-dimensional computed tomography images. Issue 4 (1st June 2014)
- Main Title:
- Comparison of patient-specific internal gross tumor volume for radiation treatment of primary esophageal cancer based separately on three-dimensional and four-dimensional computed tomography images
- Authors:
- Wang, W.
Li, J.
Zhang, Y.
Li, F.
Xu, M.
Fan, T.
Shao, Q.
Shang, D. - Abstract:
- Summary: To compare the target volume, position and matching index of the patient-specific internal gross tumor volume (IGTV ) based on three-dimensional (3D ) and four-dimensional (4D ) computed tomography (CT ) images for primary esophageal cancer. Twenty-nine patients with primary thoracic esophageal cancer underwent 3DCT and 4DCT scans during free breathing. IGTVs were constructed using three approaches: combining the gross target volumes from the 10 respiratory phases of the 4DCT dataset to produce IGTV10 ; IGTV2 was acquired by combining the two extreme phases; and IGTV3D was created from the 3DCT -based gross target volume by enlarging the 95th percentile of motion in each direction measured by the 4DCT . 0.16 cm lateral (LR ), 0.14 cm anteroposterior (AP ) and 0.29 cm superoinferior (SI ) in the upper; 0.18 cm LR, 0.10 cm AP and 0.63 cm SI in the middle; and 0.40 cm LR, 0.58 cm AP and 0.82 cm in the lower thoracic esophagus could account for 95% of respiratory-induced tumor motion. The centroid position shift between IGTV10 and IGTV2 was all below 0.10 cm, and less than 0.20 cm between IGTV10 and IGTV3D . IGTV10 was bigger than IGTV2 ; the mean value of matching index for IGTV2 to IGTV10 was 0.87 ± 0.05, 0.85 ± 0.06 and 0.83 ± 0.05 for upper, middle and distal thoracic esophageal tumors, respectively, and just 0.57 ± 0.11, 0.56 ± 0.13 and 0.40 ± 0.03 between IGTV3D and IGTV10 . 4DCT -based IGTV10 is a reasonable patient-specific IGTV for primary thoracic esophagealSummary: To compare the target volume, position and matching index of the patient-specific internal gross tumor volume (IGTV ) based on three-dimensional (3D ) and four-dimensional (4D ) computed tomography (CT ) images for primary esophageal cancer. Twenty-nine patients with primary thoracic esophageal cancer underwent 3DCT and 4DCT scans during free breathing. IGTVs were constructed using three approaches: combining the gross target volumes from the 10 respiratory phases of the 4DCT dataset to produce IGTV10 ; IGTV2 was acquired by combining the two extreme phases; and IGTV3D was created from the 3DCT -based gross target volume by enlarging the 95th percentile of motion in each direction measured by the 4DCT . 0.16 cm lateral (LR ), 0.14 cm anteroposterior (AP ) and 0.29 cm superoinferior (SI ) in the upper; 0.18 cm LR, 0.10 cm AP and 0.63 cm SI in the middle; and 0.40 cm LR, 0.58 cm AP and 0.82 cm in the lower thoracic esophagus could account for 95% of respiratory-induced tumor motion. The centroid position shift between IGTV10 and IGTV2 was all below 0.10 cm, and less than 0.20 cm between IGTV10 and IGTV3D . IGTV10 was bigger than IGTV2 ; the mean value of matching index for IGTV2 to IGTV10 was 0.87 ± 0.05, 0.85 ± 0.06 and 0.83 ± 0.05 for upper, middle and distal thoracic esophageal tumors, respectively, and just 0.57 ± 0.11, 0.56 ± 0.13 and 0.40 ± 0.03 between IGTV3D and IGTV10 . 4DCT -based IGTV10 is a reasonable patient-specific IGTV for primary thoracic esophageal cancer, and IGTV2 is considered as an acceptable alternative to IGTV10 . However, it seems unreasonable to use IGTV3D substitute IGTV10 . … (more)
- Is Part Of:
- Diseases of the esophagus. Volume 27:Issue 4(2014)
- Journal:
- Diseases of the esophagus
- Issue:
- Volume 27:Issue 4(2014)
- Issue Display:
- Volume 27, Issue 4 (2014)
- Year:
- 2014
- Volume:
- 27
- Issue:
- 4
- Issue Sort Value:
- 2014-0027-0004-0000
- Page Start:
- 348
- Page End:
- 354
- Publication Date:
- 2014-06-01
- Subjects:
- 3DCT -- 4DCT -- esophageal cancer -- internal gross tumor volume -- radiotherapy
Esophagus -- Diseases -- Periodicals
616.32 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1442-2050 ↗
http://www.wiley.com/bw/journal.asp?ref=1120-8694 ↗
https://academic.oup.com/dote ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/dote.12089 ↗
- Languages:
- English
- ISSNs:
- 1120-8694
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3598.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25148.xml