Combined structure–function analysis in glaucoma screening. Issue 12 (6th July 2021)
- Record Type:
- Journal Article
- Title:
- Combined structure–function analysis in glaucoma screening. Issue 12 (6th July 2021)
- Main Title:
- Combined structure–function analysis in glaucoma screening
- Authors:
- Karvonen, Elina
Stoor, Katri
Luodonpää, Marja
Hägg, Pasi
Leiviskä, Ilmari
Liinamaa, Johanna
Tuulonen, Anja
Saarela, Ville - Abstract:
- Abstract : Aim: To assess the applicability of a structure–function (S-F) analysis combining spectral-domain optical coherence tomography (SD-OCT) and standard automated perimetry (SAP) in glaucoma screening in a middle-aged population. Methods: A randomised sample of 3001 Caucasian participants aged 45–49 years of the Northern Finland Birth Cohort Eye Study was examined. We performed an eye examination, including 24–2 SAP, optic nerve head (ONH) and retinal nerve fibre layer (RNFL) photography and SD-OCT of the peripapillary RNFL. The S-F report was generated by Forum Glaucoma Workplace software. OCT, SAP and the S-F analysis were evaluated against clinical glaucoma diagnosis, that is, the positive '2 out of 3' rule based on the clinician's evaluation of ONH and RNFL photographs and visual fields (VFs). Results: At a specificity of 97.5%, the sensitivity for glaucomatous damage was 26% for abnormal OCT, 35% for SAP and 44% for S-F analysis. Estimated areas under the curve were 0.74, 0.85 and 0.76, and the corresponding positive predictive values were 8 %, 10% and 12%, respectively. By applying a classification tree approach combining OCT, SAP and defect localisation data, a sensitivity of 77% was achieved at 90% specificity. In a localisation analysis of glaucomatous structural and functional defects, the correlation with glaucoma increased significantly if the abnormal VF test points were located on borderline or abnormal OCT zones. Conclusion: SAP performs slightly betterAbstract : Aim: To assess the applicability of a structure–function (S-F) analysis combining spectral-domain optical coherence tomography (SD-OCT) and standard automated perimetry (SAP) in glaucoma screening in a middle-aged population. Methods: A randomised sample of 3001 Caucasian participants aged 45–49 years of the Northern Finland Birth Cohort Eye Study was examined. We performed an eye examination, including 24–2 SAP, optic nerve head (ONH) and retinal nerve fibre layer (RNFL) photography and SD-OCT of the peripapillary RNFL. The S-F report was generated by Forum Glaucoma Workplace software. OCT, SAP and the S-F analysis were evaluated against clinical glaucoma diagnosis, that is, the positive '2 out of 3' rule based on the clinician's evaluation of ONH and RNFL photographs and visual fields (VFs). Results: At a specificity of 97.5%, the sensitivity for glaucomatous damage was 26% for abnormal OCT, 35% for SAP and 44% for S-F analysis. Estimated areas under the curve were 0.74, 0.85 and 0.76, and the corresponding positive predictive values were 8 %, 10% and 12%, respectively. By applying a classification tree approach combining OCT, SAP and defect localisation data, a sensitivity of 77% was achieved at 90% specificity. In a localisation analysis of glaucomatous structural and functional defects, the correlation with glaucoma increased significantly if the abnormal VF test points were located on borderline or abnormal OCT zones. Conclusion: SAP performs slightly better than OCT in glaucoma screening of middle-aged population. However, the diagnostic capability can be improved by S-F analysis. … (more)
- Is Part Of:
- British journal of ophthalmology. Volume 106:Issue 12(2022)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 106:Issue 12(2022)
- Issue Display:
- Volume 106, Issue 12 (2022)
- Year:
- 2022
- Volume:
- 106
- Issue:
- 12
- Issue Sort Value:
- 2022-0106-0012-0000
- Page Start:
- 1689
- Page End:
- 1695
- Publication Date:
- 2021-07-06
- Subjects:
- diagnostic tests/investigation -- epidemiology -- glaucoma -- imaging
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjophthalmol-2021-319178 ↗
- Languages:
- English
- ISSNs:
- 0007-1161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25141.xml