Dosimetric and feasibility evaluation of a CBCT‐based daily adaptive radiotherapy protocol for locally advanced cervical cancer. Issue 1 (8th October 2022)
- Record Type:
- Journal Article
- Title:
- Dosimetric and feasibility evaluation of a CBCT‐based daily adaptive radiotherapy protocol for locally advanced cervical cancer. Issue 1 (8th October 2022)
- Main Title:
- Dosimetric and feasibility evaluation of a CBCT‐based daily adaptive radiotherapy protocol for locally advanced cervical cancer
- Authors:
- Branco, Daniela
Mayadev, Jyoti
Moore, Kevin
Ray, Xenia - Abstract:
- Abstract: Purpose: Evaluate a cone‐beam computed tomography (CBCT)‐based daily adaptive platform in cervical cancer for multiple endpoints: (1) physics contouring accuracy of daily CTVs, (2) CTV coverage with adapted plans and reduced PTV margins versus non‐adapted plans with standard‐of‐care (SOC) margins, (3) dosimetric improvements to CTV and organs‐at‐risk (OARs), and (4) on‐couch time. Methods and materials: Using a Varian Ethos™ emulator and KV‐CBCT scans, we simulated the doses 15 retrospective cervical cancer patients would have received with/without online adaptation for five fractions. We compared contours and doses from SOC plans (5–15 mm CTV‐to‐PTV margins) to adapted plans (3 mm margins). Auto‐segmented CTVs and OARs were reviewed and edited by trained physicists. Physics‐edited targets were evaluated by an oncologist. Time spent reviewing and editing auto‐segmented structures was recorded. Metrics from the CTV (D99%), bowel (V45Gy, V40Gy), bladder (D50%), and rectum (D50%) were compared. Results: The physician approved the physics‐edited CTVs for 55/75 fractions; 16/75 required reductions, and 4/75 required CTV expansions. CTVs were encapsulated by unadapted, SOC PTVs for 56/75 (72%) fractions—representative of current clinical practice. CTVs were completely covered by adapted 3 mm PTVs for 71/75 (94.6%) fractions. CTV D99% values for adapted plans were comparable to non‐adapted SOC plans (average difference of −0.9%), while all OAR metrics improved withAbstract: Purpose: Evaluate a cone‐beam computed tomography (CBCT)‐based daily adaptive platform in cervical cancer for multiple endpoints: (1) physics contouring accuracy of daily CTVs, (2) CTV coverage with adapted plans and reduced PTV margins versus non‐adapted plans with standard‐of‐care (SOC) margins, (3) dosimetric improvements to CTV and organs‐at‐risk (OARs), and (4) on‐couch time. Methods and materials: Using a Varian Ethos™ emulator and KV‐CBCT scans, we simulated the doses 15 retrospective cervical cancer patients would have received with/without online adaptation for five fractions. We compared contours and doses from SOC plans (5–15 mm CTV‐to‐PTV margins) to adapted plans (3 mm margins). Auto‐segmented CTVs and OARs were reviewed and edited by trained physicists. Physics‐edited targets were evaluated by an oncologist. Time spent reviewing and editing auto‐segmented structures was recorded. Metrics from the CTV (D99%), bowel (V45Gy, V40Gy), bladder (D50%), and rectum (D50%) were compared. Results: The physician approved the physics‐edited CTVs for 55/75 fractions; 16/75 required reductions, and 4/75 required CTV expansions. CTVs were encapsulated by unadapted, SOC PTVs for 56/75 (72%) fractions—representative of current clinical practice. CTVs were completely covered by adapted 3 mm PTVs for 71/75 (94.6%) fractions. CTV D99% values for adapted plans were comparable to non‐adapted SOC plans (average difference of −0.9%), while all OAR metrics improved with adaptation. Specifically, bowel V45Gy and V40Gy decreased on average by 87.6 and 109.4 cc, while bladder and rectum D50% decreased by 37.7% and 35.8%, respectively. The time required for contouring and calculating an adaptive plan for 65/75 fractions was less than 20 min (range: 1–29 min). Conclusions: Improved dose metrics with daily adaption could translate to reduced toxicity while maintaining tumor control. Training physicists to perform contouring edits could minimize the time physicians are required at adaptive sessions improving clinical efficiency. All emulated adaptive sessions were completed within 30 min however extra time will be required for patient setup, image acquisition, and treatment delivery. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 24:Issue 1(2023)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 24:Issue 1(2023)
- Issue Display:
- Volume 24, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 24
- Issue:
- 1
- Issue Sort Value:
- 2023-0024-0001-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2022-10-08
- Subjects:
- adaptive radiotherapy -- cervical cancer -- cone‐beam CT -- dosimetry -- image‐guided radiotherapy -- target margins
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13783 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25095.xml