Quantification of aortic flow by phase-contrast magnetic resonance in patients with bicuspid aortic valve. (14th July 2013)
- Record Type:
- Journal Article
- Title:
- Quantification of aortic flow by phase-contrast magnetic resonance in patients with bicuspid aortic valve. (14th July 2013)
- Main Title:
- Quantification of aortic flow by phase-contrast magnetic resonance in patients with bicuspid aortic valve
- Authors:
- Muzzarelli, S.
Monney, P.
O'Brien, K.
Faletra, F.
Moccetti, T.
Vogt, P.
Schwitter, J. - Abstract:
- Abstract: Aims: Bicuspid aortic valve (BAV) causes complex flow patterns in the ascending aorta (AAo), which may compromise the accuracy of flow measurement by phase-contrast magnetic resonance (PC-MR). Therefore, we aimed to assess and compare the accuracy of forward flow measurement in the AAo, where complex flow is more dominant in BAV patients, with flow quantification in the left ventricular outflow tract (LVOT) and the aortic valve orifice (AV), where complex flow is less important, in BAV patients and controls. Methods and results: Flow was measured by PC-MR in 22 BAV patients and 20 controls at the following positions: (i) LVOT, (ii) AV, and (iii) AAo, and compared with the left ventricular stroke volume (LVSV). The correlation between the LVSV and the forward flow in the LVOT, the AV, and the AAo was good in BAV patients ( r = 0.97/0.96/0.93; P < 0.01) and controls ( r = 0.96/0.93/0.93; P < 0.01). However, in relation with the LVSV, the forward flow in the AAo was mildly underestimated in controls and much more in BAV patients [median (inter-quartile range): 9% (4%/15%) vs. 22% (8%/30%); P < 0.01]. This was not the case in the LVOT and the AV. The severity of flow underestimation in the AAo was associated with flow eccentricity. Conclusion: Flow measurement in the AAo leads to an underestimation of the forward flow in BAV patients. Measurement in the LVOT or the AV, where complex flow is less prominent, is an alternative means for quantifying the systolic forwardAbstract: Aims: Bicuspid aortic valve (BAV) causes complex flow patterns in the ascending aorta (AAo), which may compromise the accuracy of flow measurement by phase-contrast magnetic resonance (PC-MR). Therefore, we aimed to assess and compare the accuracy of forward flow measurement in the AAo, where complex flow is more dominant in BAV patients, with flow quantification in the left ventricular outflow tract (LVOT) and the aortic valve orifice (AV), where complex flow is less important, in BAV patients and controls. Methods and results: Flow was measured by PC-MR in 22 BAV patients and 20 controls at the following positions: (i) LVOT, (ii) AV, and (iii) AAo, and compared with the left ventricular stroke volume (LVSV). The correlation between the LVSV and the forward flow in the LVOT, the AV, and the AAo was good in BAV patients ( r = 0.97/0.96/0.93; P < 0.01) and controls ( r = 0.96/0.93/0.93; P < 0.01). However, in relation with the LVSV, the forward flow in the AAo was mildly underestimated in controls and much more in BAV patients [median (inter-quartile range): 9% (4%/15%) vs. 22% (8%/30%); P < 0.01]. This was not the case in the LVOT and the AV. The severity of flow underestimation in the AAo was associated with flow eccentricity. Conclusion: Flow measurement in the AAo leads to an underestimation of the forward flow in BAV patients. Measurement in the LVOT or the AV, where complex flow is less prominent, is an alternative means for quantifying the systolic forward flow in BAV patients. … (more)
- Is Part Of:
- European heart journal. Volume 15:Number 1(2014:Jan.)
- Journal:
- European heart journal
- Issue:
- Volume 15:Number 1(2014:Jan.)
- Issue Display:
- Volume 15, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 15
- Issue:
- 1
- Issue Sort Value:
- 2014-0015-0001-0000
- Page Start:
- 77
- Page End:
- 84
- Publication Date:
- 2013-07-14
- Subjects:
- phase-contrast magnetic resonance -- flow -- aortic valve regurgitation -- bicuspid aortic valve
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.10754 - Journal URLs:
- http://ehjcimaging.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/jet129 ↗
- Languages:
- English
- ISSNs:
- 2047-2404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25111.xml