Three-dimensional whole-heart vs. two-dimensional high-resolution perfusion-CMR: a pilot study comparing myocardial ischaemic burden. (7th October 2015)
- Record Type:
- Journal Article
- Title:
- Three-dimensional whole-heart vs. two-dimensional high-resolution perfusion-CMR: a pilot study comparing myocardial ischaemic burden. (7th October 2015)
- Main Title:
- Three-dimensional whole-heart vs. two-dimensional high-resolution perfusion-CMR: a pilot study comparing myocardial ischaemic burden
- Authors:
- McDiarmid, Adam K.
Ripley, David P.
Mohee, Kevin
Kozerke, Sebastian
Greenwood, John P.
Plein, Sven
Motwani, Manish - Abstract:
- Abstract: Aims: Typically, myocardial perfusion imaging with two-dimensional (2D) cardiovascular magnetic resonance (CMR) acquires data in three to four myocardial slices at a spatial resolution of 2–3 mm. However, accelerated data acquisition can facilitate higher spatial resolution (<2 mm) or three-dimensional (3D) whole-heart coverage (up to 16 slices). This study aims to compare image quality, diagnostic confidence, and quantitation of myocardial ischaemic burden (MIB) between 2D high-resolution and 3D whole-heart perfusion-CMR. Methods and results: Twenty-seven patients with stable angina underwent both high-resolution 2D and whole-heart 3D perfusion-CMR. Total perfusion defect (TPD) and total scar burden (TSB) areas were contoured and expressed as percentage myocardium. MIB was calculated by subtracting TSB from TPD. Image quality, artefact, and diagnostic confidence scores were similar for both techniques ( P >0.05). The mean MIB from high-resolution and 3D acquisition was similar (4.3±5.2% vs. 4.1±4.9%; P =0.81), with a strong correlation between techniques ( r =0.72; P <0.001). There was no systematic bias for estimates of MIB between techniques [mean bias=−0.17%, 95% confidence interval (CI): −1.7 to –1.3%] and the 95% limits of agreement were −7.5 to 7.2%. When used to categorize MIB as >10% or <10%, there was only fair agreement between the two techniques ( κ =0.29, 95% CI: −0.12 to 0.70). Conclusion: There is strong correlation and broad agreement betweenAbstract: Aims: Typically, myocardial perfusion imaging with two-dimensional (2D) cardiovascular magnetic resonance (CMR) acquires data in three to four myocardial slices at a spatial resolution of 2–3 mm. However, accelerated data acquisition can facilitate higher spatial resolution (<2 mm) or three-dimensional (3D) whole-heart coverage (up to 16 slices). This study aims to compare image quality, diagnostic confidence, and quantitation of myocardial ischaemic burden (MIB) between 2D high-resolution and 3D whole-heart perfusion-CMR. Methods and results: Twenty-seven patients with stable angina underwent both high-resolution 2D and whole-heart 3D perfusion-CMR. Total perfusion defect (TPD) and total scar burden (TSB) areas were contoured and expressed as percentage myocardium. MIB was calculated by subtracting TSB from TPD. Image quality, artefact, and diagnostic confidence scores were similar for both techniques ( P >0.05). The mean MIB from high-resolution and 3D acquisition was similar (4.3±5.2% vs. 4.1±4.9%; P =0.81), with a strong correlation between techniques ( r =0.72; P <0.001). There was no systematic bias for estimates of MIB between techniques [mean bias=−0.17%, 95% confidence interval (CI): −1.7 to –1.3%] and the 95% limits of agreement were −7.5 to 7.2%. When used to categorize MIB as >10% or <10%, there was only fair agreement between the two techniques ( κ =0.29, 95% CI: −0.12 to 0.70). Conclusion: There is strong correlation and broad agreement between estimates of MIB from both techniques. However, the 95% limits of agreement are relatively wide and therefore a larger comparative study is needed before they can be considered interchangeable—particularly around the clinically relevant 10% threshold. … (more)
- Is Part Of:
- European heart journal. Volume 17:Number 8(2016:Aug.)
- Journal:
- European heart journal
- Issue:
- Volume 17:Number 8(2016:Aug.)
- Issue Display:
- Volume 17, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 17
- Issue:
- 8
- Issue Sort Value:
- 2016-0017-0008-0000
- Page Start:
- 900
- Page End:
- 908
- Publication Date:
- 2015-10-07
- Subjects:
- coronary artery disease -- magnetic resonance imaging -- ischaemia -- myocardial perfusion imaging
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.10754 - Journal URLs:
- http://ehjcimaging.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/jev231 ↗
- Languages:
- English
- ISSNs:
- 2047-2404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25094.xml