A deep-learning method for generating synthetic kV-CT and improving tumor segmentation for helical tomotherapy of nasopharyngeal carcinoma. (11th November 2021)
- Record Type:
- Journal Article
- Title:
- A deep-learning method for generating synthetic kV-CT and improving tumor segmentation for helical tomotherapy of nasopharyngeal carcinoma. (11th November 2021)
- Main Title:
- A deep-learning method for generating synthetic kV-CT and improving tumor segmentation for helical tomotherapy of nasopharyngeal carcinoma
- Authors:
- Chen, Xinyuan
Yang, Bining
Li, Jingwen
Zhu, Ji
Ma, Xiangyu
Chen, Deqi
Hu, Zhihui
Men, Kuo
Dai, Jianrong - Abstract:
- Abstract: Objective: Megavoltage computed tomography (MV-CT) is used for setup verification and adaptive radiotherapy in tomotherapy. However, its low contrast and high noise lead to poor image quality. This study aimed to develop a deep-learning-based method to generate synthetic kilovoltage CT (skV-CT) and then evaluate its ability to improve image quality and tumor segmentation. Approach: The planning kV-CT and MV-CT images of 270 patients with nasopharyngeal carcinoma (NPC) treated on an Accuray TomoHD system were used. An improved cycle-consistent adversarial network which used residual blocks as its generator was adopted to learn the mapping between MV-CT and kV-CT and then generate skV-CT from MV-CT. A Catphan 700 phantom and 30 patients with NPC were used to evaluate image quality. The quantitative indices included contrast-to-noise ratio (CNR), uniformity and signal-to-noise ratio (SNR) for the phantom and the structural similarity index measure (SSIM), mean absolute error (MAE), and peak signal-to-noise ratio (PSNR) for patients. Next, we trained three models for segmentation of the clinical target volume (CTV): MV-CT, skV-CT, and MV-CT combined with skV-CT. The segmentation accuracy was compared with indices of the dice similarity coefficient (DSC) and mean distance agreement (MDA). Main results: Compared with MV-CT, skV-CT showed significant improvement in CNR (184.0%), image uniformity (34.7%), and SNR (199.0%) in the phantom study and improved SSIM (1.7%), MAEAbstract: Objective: Megavoltage computed tomography (MV-CT) is used for setup verification and adaptive radiotherapy in tomotherapy. However, its low contrast and high noise lead to poor image quality. This study aimed to develop a deep-learning-based method to generate synthetic kilovoltage CT (skV-CT) and then evaluate its ability to improve image quality and tumor segmentation. Approach: The planning kV-CT and MV-CT images of 270 patients with nasopharyngeal carcinoma (NPC) treated on an Accuray TomoHD system were used. An improved cycle-consistent adversarial network which used residual blocks as its generator was adopted to learn the mapping between MV-CT and kV-CT and then generate skV-CT from MV-CT. A Catphan 700 phantom and 30 patients with NPC were used to evaluate image quality. The quantitative indices included contrast-to-noise ratio (CNR), uniformity and signal-to-noise ratio (SNR) for the phantom and the structural similarity index measure (SSIM), mean absolute error (MAE), and peak signal-to-noise ratio (PSNR) for patients. Next, we trained three models for segmentation of the clinical target volume (CTV): MV-CT, skV-CT, and MV-CT combined with skV-CT. The segmentation accuracy was compared with indices of the dice similarity coefficient (DSC) and mean distance agreement (MDA). Main results: Compared with MV-CT, skV-CT showed significant improvement in CNR (184.0%), image uniformity (34.7%), and SNR (199.0%) in the phantom study and improved SSIM (1.7%), MAE (24.7%), and PSNR (7.5%) in the patient study. For CTV segmentation with only MV-CT, only skV-CT, and MV-CT combined with skV-CT, the DSCs were 0.75 ± 0.04, 0.78 ± 0.04, and 0.79 ± 0.03, respectively, and the MDAs (in mm) were 3.69 ± 0.81, 3.14 ± 0.80, and 2.90 ± 0.62, respectively. Significance: The proposed method improved the image quality of MV-CT and thus tumor segmentation in helical tomotherapy. The method potentially can benefit adaptive radiotherapy. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 66:Number 22(2021)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 66:Number 22(2021)
- Issue Display:
- Volume 66, Issue 22 (2021)
- Year:
- 2021
- Volume:
- 66
- Issue:
- 22
- Issue Sort Value:
- 2021-0066-0022-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-11-11
- Subjects:
- megavoltage CT -- synthetic kilovoltage CT -- deep learning -- cycle-consistent adversarial networks -- CycleGAN -- image quality -- tumor segmentation
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/ac3345 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25120.xml