Pilot study of oblique lumbar interbody fusion using mobile percutaneous pedicle screw and validation by a three-dimensional finite element assessment. (June 2020)
- Record Type:
- Journal Article
- Title:
- Pilot study of oblique lumbar interbody fusion using mobile percutaneous pedicle screw and validation by a three-dimensional finite element assessment. (June 2020)
- Main Title:
- Pilot study of oblique lumbar interbody fusion using mobile percutaneous pedicle screw and validation by a three-dimensional finite element assessment
- Authors:
- Eguchi, Yawara
Orita, Sumihisa
Yamada, Hiroyuki
Suzuki, Munetaka
Yamanaka, Hajime
Tamai, Hiroshi
Inage, Kazuhide
Narita, Miyako
Shiga, Yasuhiro
Inoue, Masahiro
Norimoto, Masaki
Umimura, Tomotaka
Sato, Takashi
Suzuki, Masahiro
Enomoto, Keigo
Koda, Masao
Furuya, Takeo
Maki, Satoshi
Hirosawa, Naoya
Aoki, Yasuchika
Nakamura, Junichi
Hagiwara, Shigeo
Akazawa, Tsutomu
Takahashi, Hiroshi
Takahashi, Kazuhisa
Shiko, Yuki
Kawasaki, Yohei
Ohtori, Seiji - Abstract:
- Highlights: We compared the surgical results of oblique lateral interbody fusion (OLIF) using conventional percutaneous pedicle screws (PPS) with mobile PPS, as part of the posterior dynamic stabilization system. Bone fusion was significantly shortened with mobile PPS (4.8 months) compared to conventional PPS (18 months). The finite element analysis showed that higher compressive force on the cage would promotes bone healing. The mobile screw combination OLIF promotes cage bone healing and may be a more effective vertebral fusion technique. Abstract: The purpose of this study was to try oblique lateral interbody fusion (OLIF) using percutaneous pedicle screws (PPS) with mobility. Twelve patients who underwent single-level OLIF were observed for at least one year. These included 6 patients with conventional PPS (rigid group), and 6 with movable PPS (semi-rigid group). Mobile PPS used cosmicMIA, which is a load sharing system. The anterior and posterior disc height, screw loosening and bone healing period, and implant failure were evaluated at final observation by CT. Moreover, the stress on the vertebral body-cage, on the vertebral body-screw/rod and on the bone around the screw was estimated using a three-dimensional finite element assessment in both groups. There was no significant difference in surgical time, amount of bleeding, JOA score, or low back pain VAS between groups. There were no differences between groups in anterior and posterior disc height, screw loosening,Highlights: We compared the surgical results of oblique lateral interbody fusion (OLIF) using conventional percutaneous pedicle screws (PPS) with mobile PPS, as part of the posterior dynamic stabilization system. Bone fusion was significantly shortened with mobile PPS (4.8 months) compared to conventional PPS (18 months). The finite element analysis showed that higher compressive force on the cage would promotes bone healing. The mobile screw combination OLIF promotes cage bone healing and may be a more effective vertebral fusion technique. Abstract: The purpose of this study was to try oblique lateral interbody fusion (OLIF) using percutaneous pedicle screws (PPS) with mobility. Twelve patients who underwent single-level OLIF were observed for at least one year. These included 6 patients with conventional PPS (rigid group), and 6 with movable PPS (semi-rigid group). Mobile PPS used cosmicMIA, which is a load sharing system. The anterior and posterior disc height, screw loosening and bone healing period, and implant failure were evaluated at final observation by CT. Moreover, the stress on the vertebral body-cage, on the vertebral body-screw/rod and on the bone around the screw was estimated using a three-dimensional finite element assessment in both groups. There was no significant difference in surgical time, amount of bleeding, JOA score, or low back pain VAS between groups. There were no differences between groups in anterior and posterior disc height, screw loosening, and implant failure at final observation. The bone healing period was significantly shorter in the semi-rigid screw group (18.3 months vs 4.8 months, p = 0.01). The finite element analysis showed that the lower stress on the rod/screw would contribute to fewer implant fractures and that lower stress on the bone around the screw would reduce screw loosening, and that higher compressive force on the cage would promotes bone healing. OLIF combined with a movable screw accelerated bone healing by nearly 75%. We conclude that mobile PPS in combination with OLIF promotes bone healing and can be a better vertebral fusion technique. … (more)
- Is Part Of:
- Journal of clinical neuroscience. Volume 76(2020)
- Journal:
- Journal of clinical neuroscience
- Issue:
- Volume 76(2020)
- Issue Display:
- Volume 76, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 76
- Issue:
- 2020
- Issue Sort Value:
- 2020-0076-2020-0000
- Page Start:
- 74
- Page End:
- 80
- Publication Date:
- 2020-06
- Subjects:
- Oblique lumbar interbody fusion -- Load sharing -- Lumbar segmental mobility -- Pedicle screw -- Finite element analysis
Brain -- Surgery -- Periodicals
Neurosciences -- Periodicals
Nervous system -- Surgery -- Periodicals
Brain -- surgery -- Periodicals
Neurosurgical Procedures -- Periodicals
Neurosciences -- Periodicals
Electronic journals
616.8 - Journal URLs:
- http://www.harcourt-international.com/journals ↗
http://www.sciencedirect.com/science/journal/09675868 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/09675868 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jocn.2020.04.043 ↗
- Languages:
- English
- ISSNs:
- 0967-5868
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.585000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25108.xml