Quantification of left atrial volumes using three-dimensional wall motion tracking echocardiographic technology: comparison with cardiac magnetic resonance. (30th January 2014)
- Record Type:
- Journal Article
- Title:
- Quantification of left atrial volumes using three-dimensional wall motion tracking echocardiographic technology: comparison with cardiac magnetic resonance. (30th January 2014)
- Main Title:
- Quantification of left atrial volumes using three-dimensional wall motion tracking echocardiographic technology: comparison with cardiac magnetic resonance
- Authors:
- Perez de Isla, Leopoldo
Feltes, Gisela
Moreno, Joel
Martinez, Wilfredo
Saltijeral, Adriana
de Agustin, Jose A.
Gomez de Diego, Jose Juan
Marcos-Alberca, Pedro
Luaces, María
Ferreiros, Joaquin
Garcia Fernandez, Miguel Angel
Macaya, Carlos - Abstract:
- Abstract: Background: Left atrium (LA) size assessment is clinically relevant, but the accuracy of two-dimensional echocardiographic (2D-echo) methods is limited. Three-dimensional (3D) echocardiography is an excellent alternative but is far from being used in daily clinical practice. Three-dimensional-wall motion tracking (3D-WMT) allows us to obtain volumes in a very simple and rapid manner. The aims of this study were to evaluate the accuracy of 3D-WMT technology to assess LA volume using cardiac magnetic resonance (CMR) as a reference method, to evaluate its reproducibility, and to determine its added clinical value to classify the LA enlargement severity. Methods and results: Seventy consecutive patients referred for a CMR study were prospectively enrolled. They underwent LA volume assessment by means of 2D-echo, 3D-WMT, and CMR. Inter-methods agreement was assessed. The mean age was 56 ± 18 years and 42 patients (60%) were males. Average maximal LA volume obtained by 2D-echo, 3D-WMT, and CMR were 63.33 ± 26.82, 79.80 ± 29.0, and 79.80 ± 28.99 mL, respectively. Univariate linear regression analysis showed a good correlation between 3D-WMT and CMR ( r = 0.83; P < 0.001). The agreement analysis showed a similar result (ICC = 0.83; 95% CI = 0.74–0.89; P < 0.001). Furthermore, the LA enlargement degree was better evaluated with 3D-WMT than with 2D-echo. Conclusion: This study validates LA volume measurements obtained using the new and fast 3D-WMT technology, compared withAbstract: Background: Left atrium (LA) size assessment is clinically relevant, but the accuracy of two-dimensional echocardiographic (2D-echo) methods is limited. Three-dimensional (3D) echocardiography is an excellent alternative but is far from being used in daily clinical practice. Three-dimensional-wall motion tracking (3D-WMT) allows us to obtain volumes in a very simple and rapid manner. The aims of this study were to evaluate the accuracy of 3D-WMT technology to assess LA volume using cardiac magnetic resonance (CMR) as a reference method, to evaluate its reproducibility, and to determine its added clinical value to classify the LA enlargement severity. Methods and results: Seventy consecutive patients referred for a CMR study were prospectively enrolled. They underwent LA volume assessment by means of 2D-echo, 3D-WMT, and CMR. Inter-methods agreement was assessed. The mean age was 56 ± 18 years and 42 patients (60%) were males. Average maximal LA volume obtained by 2D-echo, 3D-WMT, and CMR were 63.33 ± 26.82, 79.80 ± 29.0, and 79.80 ± 28.99 mL, respectively. Univariate linear regression analysis showed a good correlation between 3D-WMT and CMR ( r = 0.83; P < 0.001). The agreement analysis showed a similar result (ICC = 0.83; 95% CI = 0.74–0.89; P < 0.001). Furthermore, the LA enlargement degree was better evaluated with 3D-WMT than with 2D-echo. Conclusion: This study validates LA volume measurements obtained using the new and fast 3D-WMT technology, compared with CMR. This method is fast, accurate, and reproducible, and it allows a better classification of left LA enlargement severity compared with 2D-echo. … (more)
- Is Part Of:
- European heart journal. Volume 15:Number 7(2014:Jul.)
- Journal:
- European heart journal
- Issue:
- Volume 15:Number 7(2014:Jul.)
- Issue Display:
- Volume 15, Issue 7 (2014)
- Year:
- 2014
- Volume:
- 15
- Issue:
- 7
- Issue Sort Value:
- 2014-0015-0007-0000
- Page Start:
- 793
- Page End:
- 799
- Publication Date:
- 2014-01-30
- Subjects:
- Three-dimensional echocardiography -- 3D-wall motion tracking -- Left atrium -- Cardiac magnetic resonance
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.10754 - Journal URLs:
- http://ehjcimaging.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/jeu001 ↗
- Languages:
- English
- ISSNs:
- 2047-2404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25098.xml