The contact mechanics and occurrence of edge loading in modular metal-on-polyethylene total hip replacement during daily activities. Issue 6 (June 2016)
- Record Type:
- Journal Article
- Title:
- The contact mechanics and occurrence of edge loading in modular metal-on-polyethylene total hip replacement during daily activities. Issue 6 (June 2016)
- Main Title:
- The contact mechanics and occurrence of edge loading in modular metal-on-polyethylene total hip replacement during daily activities
- Authors:
- Hua, Xijin
Li, Junyan
Jin, Zhongmin
Fisher, John - Abstract:
- Highlights: The contribution of patient daily activities to edge loading was investigated. Edge loading was predicted during normal walking, ascending and descending stairs activities. No edge loading was observed during standing up, sitting down and knee bending activities. Edge loading caused elevated contact pressure and equivalent plastic strain of liner. Abstract: The occurrence of edge loading in hip joint replacement has been associated with many factors such as prosthetic design, component malposition and activities of daily living. The present study aimed to quantify the occurrence of edge loading/contact at the articulating surface and to evaluate the effect of cup angles and edge loading on the contact mechanics of a modular metal-on-polyethylene (MoP) total hip replacement (THR) during different daily activities. A three-dimensional finite element model was developed based on a modular MoP bearing system. Different cup inclination and anteversion angles were modelled and six daily activities were considered. The results showed that edge loading was predicted during normal walking, ascending and descending stairs activities under steep cup inclination conditions (≥55°) while no edge loading was observed during standing up, sitting down and knee bending activities. The duration of edge loading increased with increased cup inclination angles and was affected by the cup anteversion angles. Edge loading caused elevated contact pressure at the articulating surface andHighlights: The contribution of patient daily activities to edge loading was investigated. Edge loading was predicted during normal walking, ascending and descending stairs activities. No edge loading was observed during standing up, sitting down and knee bending activities. Edge loading caused elevated contact pressure and equivalent plastic strain of liner. Abstract: The occurrence of edge loading in hip joint replacement has been associated with many factors such as prosthetic design, component malposition and activities of daily living. The present study aimed to quantify the occurrence of edge loading/contact at the articulating surface and to evaluate the effect of cup angles and edge loading on the contact mechanics of a modular metal-on-polyethylene (MoP) total hip replacement (THR) during different daily activities. A three-dimensional finite element model was developed based on a modular MoP bearing system. Different cup inclination and anteversion angles were modelled and six daily activities were considered. The results showed that edge loading was predicted during normal walking, ascending and descending stairs activities under steep cup inclination conditions (≥55°) while no edge loading was observed during standing up, sitting down and knee bending activities. The duration of edge loading increased with increased cup inclination angles and was affected by the cup anteversion angles. Edge loading caused elevated contact pressure at the articulating surface and substantially increased equivalent plastic strain of the polyethylene liner. The present study suggested that correct positioning the component to avoid edge loading that may occur during daily activities is important for MoP THR in clinical practice. … (more)
- Is Part Of:
- Medical engineering & physics. Volume 38:Issue 6(2016:Jun.)
- Journal:
- Medical engineering & physics
- Issue:
- Volume 38:Issue 6(2016:Jun.)
- Issue Display:
- Volume 38, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 38
- Issue:
- 6
- Issue Sort Value:
- 2016-0038-0006-0000
- Page Start:
- 518
- Page End:
- 525
- Publication Date:
- 2016-06
- Subjects:
- Edge loading -- Activities -- Metal-on-polyethylene -- Contact mechanics -- Cup angles
Biomedical engineering -- Periodicals
Biomedical Engineering -- Periodicals
Physics -- Periodicals
Génie biomédical -- Périodiques
Biomedical engineering
Electronic journals
Periodicals
610.28 - Journal URLs:
- http://www.medengphys.com ↗
http://www.sciencedirect.com/science/journal/13504533 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13504533 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13504533 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.medengphy.2016.03.004 ↗
- Languages:
- English
- ISSNs:
- 1350-4533
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5527.323000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25098.xml