A study on infrared thermometer measurement capabilities in the calibration laboratories and the user community in Japan. Issue 1 (1st January 2021)
- Record Type:
- Journal Article
- Title:
- A study on infrared thermometer measurement capabilities in the calibration laboratories and the user community in Japan. Issue 1 (1st January 2021)
- Main Title:
- A study on infrared thermometer measurement capabilities in the calibration laboratories and the user community in Japan
- Authors:
- Yamada, Yoshiro
Kato, Tomonori
Shimizu, Takao
Ishii, Juntaro
Iguchi, Kouichi
Ishikawa, Kenji
Honjo, Hiroyuki
Ohsuga, Naohiro
Onda, Yoshinori
Suzuki, Kaori
Tsuda, Katsunori
Yamakawa, Takayuki
Yamazaki, Takahiro - Abstract:
- Abstract : A comparison circulating a standard infrared thermometer, a handy infrared thermometer, and a thermal imager was conducted among eleven participants from the industrial user, academic user, and calibration laboratory communities of these thermometers in Japan. The result revealed that the scatter width of the reported value for the handy type thermometer was as large as 31 °C at 450 °C. Investigation into the cause of the discrepancy showed that the treatment of emissivity of the source was one large factor, which is relevant when using contact thermometer or a near infrared radiation thermometer as the reference. Large SSE of the handy thermometer linked to the definition of the targeting distance of the thermometer on the blackbody cavity also played a major role. The comparison successfully identified the shortcomings of the current calibration practices, and the result can be utilized to greatly improve the reliability of the infrared thermometer scale in future.
- Is Part Of:
- SICE journal of control, measurement, and system integration. Volume 14:Issue 1(2021)
- Journal:
- SICE journal of control, measurement, and system integration
- Issue:
- Volume 14:Issue 1(2021)
- Issue Display:
- Volume 14, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 14
- Issue:
- 1
- Issue Sort Value:
- 2021-0014-0001-0000
- Page Start:
- 107
- Page End:
- 115
- Publication Date:
- 2021-01-01
- Subjects:
- Infrared thermometer -- thermometric scale -- interlaboratory comparison -- thermal imager -- emissivity -- size-of-source effect
- DOI:
- 10.1080/18824889.2021.1917181 ↗
- Languages:
- English
- ISSNs:
- 1882-4889
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 25114.xml