Efficacy and safety of single-session radiofrequency ablation for intrathoracic goiter: preliminary results and short-term evaluation. (1st January 2021)
- Record Type:
- Journal Article
- Title:
- Efficacy and safety of single-session radiofrequency ablation for intrathoracic goiter: preliminary results and short-term evaluation. (1st January 2021)
- Main Title:
- Efficacy and safety of single-session radiofrequency ablation for intrathoracic goiter: preliminary results and short-term evaluation
- Authors:
- Chiang, Pi-Ling
Lin, Wei-Che
Chen, Hsiu-Ling
Luo, Sheng-Dean
Chen, Meng-Hsiang
Chen, Wei-Chih
Chang, Yen-Hsiang
Chou, Chen-Kai
Su, Yan-Ye
Tung, Yu-Cheng
Chen, Wen-Chieh
Chi, Shun-Yu
Baek, Jung Hwan - Abstract:
- Abstract: Background: An intrathoracic goiter (ITG) is defined as a thyroid extension below the sternal notch. Compared to cervical goiters, surgery for ITG is more challenging, with a higher risk of an extracervical approach. Ultrasound (US)-guided radiofrequency ablation (RFA) is a minimally invasive treatment modality. The purpose of this study was to prospectively evaluate the safety and efficacy of RFA in patients with ITG. Methods: From a total of 324 patients who underwent thyroid RFA at a single medical center, 15 patients (mean age 52.2 years; 73.3% female) with 16 ITGs were included and classified into three grades and three types using the cross-section imaging CT system. Clinical features and demographics, degree of extension, RFA details, goiter volume, and complications were analyzed. Results: Mean pre- and post-RFA goiter volumes as measured by US were 106.62 ± 61.82 and 25.09 ± 14.22 mL respectively, with a volume reduction rate (VRR) of 75.5% ( p < 0.001) at 6 months. The VRR as measured by CT/MRI was 57.0 ± 10.0% ( p < 0.001) at 6 months. The intrathoracic length reduction rate at 6 months was 44.9 ± 39.2% ( p = 0.001). In addition, 4 (25%) ITGs had total regression of the intrathoracic extension, with a downgrade from grade 1 to cervical goiter. Mean pre- and post-RFA symptom and cosmetic scores were 1.53 and 0.15 ( p = 0.001), and 2.67 and 2.00 ( p = 0.001), respectively. One patient had transient vocal cord palsy and another had perithyroidal andAbstract: Background: An intrathoracic goiter (ITG) is defined as a thyroid extension below the sternal notch. Compared to cervical goiters, surgery for ITG is more challenging, with a higher risk of an extracervical approach. Ultrasound (US)-guided radiofrequency ablation (RFA) is a minimally invasive treatment modality. The purpose of this study was to prospectively evaluate the safety and efficacy of RFA in patients with ITG. Methods: From a total of 324 patients who underwent thyroid RFA at a single medical center, 15 patients (mean age 52.2 years; 73.3% female) with 16 ITGs were included and classified into three grades and three types using the cross-section imaging CT system. Clinical features and demographics, degree of extension, RFA details, goiter volume, and complications were analyzed. Results: Mean pre- and post-RFA goiter volumes as measured by US were 106.62 ± 61.82 and 25.09 ± 14.22 mL respectively, with a volume reduction rate (VRR) of 75.5% ( p < 0.001) at 6 months. The VRR as measured by CT/MRI was 57.0 ± 10.0% ( p < 0.001) at 6 months. The intrathoracic length reduction rate at 6 months was 44.9 ± 39.2% ( p = 0.001). In addition, 4 (25%) ITGs had total regression of the intrathoracic extension, with a downgrade from grade 1 to cervical goiter. Mean pre- and post-RFA symptom and cosmetic scores were 1.53 and 0.15 ( p = 0.001), and 2.67 and 2.00 ( p = 0.001), respectively. One patient had transient vocal cord palsy and another had perithyroidal and mediastinal hemorrhage. Conclusion: US-guided RFA is an effective treatment for ITG in terms of both cervical and intrathoracic reductions with an acceptable complication rate. … (more)
- Is Part Of:
- International journal of hyperthermia. Volume 38:Number 1(2021)
- Journal:
- International journal of hyperthermia
- Issue:
- Volume 38:Number 1(2021)
- Issue Display:
- Volume 38, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 38
- Issue:
- 1
- Issue Sort Value:
- 2021-0038-0001-0000
- Page Start:
- 976
- Page End:
- 984
- Publication Date:
- 2021-01-01
- Subjects:
- Intrathoracic goiter -- ultrasound -- ablation technique
Thermotherapy -- Periodicals
615.832 - Journal URLs:
- http://informahealthcare.com/loi/hth ↗
http://www.tandf.co.uk/journals/titles/02656736.asp ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/02656736.2021.1942241 ↗
- Languages:
- English
- ISSNs:
- 0265-6736
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.297000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25099.xml