Percutaneous lung and liver CT-guided ablation on swine model using microwave ablation to determine ablation size for clinical practice. (1st January 2021)
- Record Type:
- Journal Article
- Title:
- Percutaneous lung and liver CT-guided ablation on swine model using microwave ablation to determine ablation size for clinical practice. (1st January 2021)
- Main Title:
- Percutaneous lung and liver CT-guided ablation on swine model using microwave ablation to determine ablation size for clinical practice
- Authors:
- Habert, Paul
Di Bisceglie, Mathieu
Hak, Jean-François
Brige, Pauline
Chopinet, Sophie
Mancini, Julien
Bartoli, Axel
Vidal, Vincent
Roux, Charles
Tselikas, Lambros
De Baere, Thierry
Gaubert, Jean-Yves - Abstract:
- Abstract: Purpose: Microwave ablation (MWA) provides an effective treatment of lung and liver tumors but suffers from a lack of reproducibility of ablation size among currently available technologies. In-vitro evaluations are far removed from clinical practices because of uninfused tissue. This study is in-vivo preclinical testing of a new MWA system on swine lungs and liver. Materials and methods: All ablations were performed under CT guidance and multiple algorithms were tested with a power of 50, 75, and 100 W for durations of 3, 5, 8, 10, and 15 min. A 3 D-evaluation of the ablation zone was carried out using enhanced-CT. The sphericity index, coefficients of variation, and energy efficiency (which corresponds to the volume yield according to the power supplied) were calculated. Results: Fifty liver and 48 lung ablations were performed in 17 swine. The sphericity index varies from 0.50 to 0.80 for liver ablations and from 0.40 to 0.69 for lung ablations. The coefficient of variation was below 15% for 4/5 and 4/8 protocols for lung and liver ablations, respectively. The energy efficiency seems to decrease with the duration of the ablation from 0.60 × 10 −3 cm 3 /J (75 W, 3 min) to 0.26 × 10 −3 cm 3 /J (100 W, 15 min) in the liver and from 0.57 × 10 −3 cm 3 /J (50 W, 10 min) to 0.42 × 10 −3 cm 3 /J (100 W, 12 min) in the lungs. Conclusion: A shorter treatment time provides the best energy efficiency, and the best reproducibility is obtained for a 10 min treatment duration.Abstract: Purpose: Microwave ablation (MWA) provides an effective treatment of lung and liver tumors but suffers from a lack of reproducibility of ablation size among currently available technologies. In-vitro evaluations are far removed from clinical practices because of uninfused tissue. This study is in-vivo preclinical testing of a new MWA system on swine lungs and liver. Materials and methods: All ablations were performed under CT guidance and multiple algorithms were tested with a power of 50, 75, and 100 W for durations of 3, 5, 8, 10, and 15 min. A 3 D-evaluation of the ablation zone was carried out using enhanced-CT. The sphericity index, coefficients of variation, and energy efficiency (which corresponds to the volume yield according to the power supplied) were calculated. Results: Fifty liver and 48 lung ablations were performed in 17 swine. The sphericity index varies from 0.50 to 0.80 for liver ablations and from 0.40 to 0.69 for lung ablations. The coefficient of variation was below 15% for 4/5 and 4/8 protocols for lung and liver ablations, respectively. The energy efficiency seems to decrease with the duration of the ablation from 0.60 × 10 −3 cm 3 /J (75 W, 3 min) to 0.26 × 10 −3 cm 3 /J (100 W, 15 min) in the liver and from 0.57 × 10 −3 cm 3 /J (50 W, 10 min) to 0.42 × 10 −3 cm 3 /J (100 W, 12 min) in the lungs. Conclusion: A shorter treatment time provides the best energy efficiency, and the best reproducibility is obtained for a 10 min treatment duration. The system tested provides an interesting reproducibility in both lung and liver measurements. Our results may help interventional radiologists in the optimal selection of treatment parameters. … (more)
- Is Part Of:
- International journal of hyperthermia. Volume 38:Number 1(2021)
- Journal:
- International journal of hyperthermia
- Issue:
- Volume 38:Number 1(2021)
- Issue Display:
- Volume 38, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 38
- Issue:
- 1
- Issue Sort Value:
- 2021-0038-0001-0000
- Page Start:
- 1140
- Page End:
- 1148
- Publication Date:
- 2021-01-01
- Subjects:
- Microwave ablation -- lung ablation -- liver ablation -- in vivo experiments -- swine model
Thermotherapy -- Periodicals
615.832 - Journal URLs:
- http://informahealthcare.com/loi/hth ↗
http://www.tandf.co.uk/journals/titles/02656736.asp ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/02656736.2021.1961883 ↗
- Languages:
- English
- ISSNs:
- 0265-6736
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.297000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25075.xml