An in vivo study of a custom-made high-frequency irreversible electroporation generator on different tissues for clinically relevant ablation zones. (1st January 2021)
- Record Type:
- Journal Article
- Title:
- An in vivo study of a custom-made high-frequency irreversible electroporation generator on different tissues for clinically relevant ablation zones. (1st January 2021)
- Main Title:
- An in vivo study of a custom-made high-frequency irreversible electroporation generator on different tissues for clinically relevant ablation zones
- Authors:
- Zhang, Bing
Liu, Fanning
Fang, Zheng
Ding, Lujia
Moser, Michael A. J.
Zhang, Wenjun - Abstract:
- Abstract: Purpose: To examine the ablation zone, muscle contractions, and temperature increases in both rabbit liver and kidney models in vivo for a custom-made high-frequency irreversible electroporation (H-FIRE) generator. Materials and Methods: A total of 18 New Zealand white rabbits were used to investigate five H-FIRE protocols ( n = 3 for each protocol) and an IRE protocol ( n = 3) for the performance of the designed H-FIRE device in both liver and kidney tissues. The ablation zone was determined by using histological analysis 72 h after treatment. The extent of muscle contractions and temperature change during the application of pulse energy were measured by a commercial accelerometer attached to animals and fiber optic temperature probe inserted into organs with IRE electrodes, respectively. Results: All H-FIRE protocols were able to generate visible ablation zones without muscle contractions, for both liver and kidney tissues. The area of ablation zone generated in H-FIRE pulse protocols (e.g., 0.3–1 μs, 2000 V, and 90–195 bursts) appears similar to that of IRE protocol (100 μs, 1000 V, and 90 pulses) in both liver and kidney tissues. No significant temperature increase was noticed except for the protocol with the highest pulse energy (e.g., 1 μs, 2000 V, and 180 bursts). Conclusion: Our work serves to complement the current H-FIRE pulse waveforms, which can be optimized to significantly improve the quality of ablation zone in terms of precision for liver andAbstract: Purpose: To examine the ablation zone, muscle contractions, and temperature increases in both rabbit liver and kidney models in vivo for a custom-made high-frequency irreversible electroporation (H-FIRE) generator. Materials and Methods: A total of 18 New Zealand white rabbits were used to investigate five H-FIRE protocols ( n = 3 for each protocol) and an IRE protocol ( n = 3) for the performance of the designed H-FIRE device in both liver and kidney tissues. The ablation zone was determined by using histological analysis 72 h after treatment. The extent of muscle contractions and temperature change during the application of pulse energy were measured by a commercial accelerometer attached to animals and fiber optic temperature probe inserted into organs with IRE electrodes, respectively. Results: All H-FIRE protocols were able to generate visible ablation zones without muscle contractions, for both liver and kidney tissues. The area of ablation zone generated in H-FIRE pulse protocols (e.g., 0.3–1 μs, 2000 V, and 90–195 bursts) appears similar to that of IRE protocol (100 μs, 1000 V, and 90 pulses) in both liver and kidney tissues. No significant temperature increase was noticed except for the protocol with the highest pulse energy (e.g., 1 μs, 2000 V, and 180 bursts). Conclusion: Our work serves to complement the current H-FIRE pulse waveforms, which can be optimized to significantly improve the quality of ablation zone in terms of precision for liver and kidney tumors in clinical setting. … (more)
- Is Part Of:
- International journal of hyperthermia. Volume 38:Number 1(2021)
- Journal:
- International journal of hyperthermia
- Issue:
- Volume 38:Number 1(2021)
- Issue Display:
- Volume 38, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 38
- Issue:
- 1
- Issue Sort Value:
- 2021-0038-0001-0000
- Page Start:
- 593
- Page End:
- 603
- Publication Date:
- 2021-01-01
- Subjects:
- High-frequency irreversible electroporation -- ablation evaluation -- muscle contraction -- temperature increase -- rabbit model
Thermotherapy -- Periodicals
615.832 - Journal URLs:
- http://informahealthcare.com/loi/hth ↗
http://www.tandf.co.uk/journals/titles/02656736.asp ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/02656736.2021.1912417 ↗
- Languages:
- English
- ISSNs:
- 0265-6736
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.297000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25075.xml