Non-contact respiration monitoring using impulse radio ultrawideband radar in neonates. Issue 6 (5th June 2019)
- Record Type:
- Journal Article
- Title:
- Non-contact respiration monitoring using impulse radio ultrawideband radar in neonates. Issue 6 (5th June 2019)
- Main Title:
- Non-contact respiration monitoring using impulse radio ultrawideband radar in neonates
- Authors:
- Kim, Jong Deok
Lee, Won Hyuk
Lee, Yonggu
Lee, Hyun Ju
Cha, Teahyen
Kim, Seung Hyun
Song, Ki-Min
Lim, Young-Hyo
Cho, Seok Hyun
Cho, Sung Ho
Park, Hyun-Kyung - Abstract:
- Abstract : Vital sign monitoring in neonates requires adhesive electrodes, which often damage fragile newborn skin. Because impulse radio ultrawideband (IR-UWB) radar has been reported to recognize chest movement without contact in adult humans, IR-UWB may be used to measure respiratory rates (RRs) in a non-contact fashion. We investigated the feasibility of radar sensors for respiration monitoring in neonates without any respiratory support to compare the accuracy and reliability of radar measurements with those of conventional impedance pneumography measurements. In the neonatal intensive care unit, RRs were measured using radar (RRRd ) and impedance pneumography (RRIP ) simultaneously. The neonatal voluntary movements were measured using the radar sensor and categorized into three levels (low [M0 ], intermediate [M1 ] and high [M2 ]). RRRd highly agreed with RRIP ( r = 0.90; intraclass correlation coefficient [ICC] = 0.846 [0.835–0.856]). For the M0 movement, there was good agreement between RRRd and RRIP (ICC = 0.893; mean bias −0.15 [limits of agreement (LOA) −9.6 to 10.0]). However, the agreement was slightly lower for the M1 (ICC = 0.833; mean bias = 0.95 [LOA −11.4 to 13.3]) and M2 (ICC = 0.749; mean bias = 3.04 [LOA –9.30 to 15.4]) movements than for the M0 movement. In conclusion, IR-UWB radar can provide accurate and reliable estimates of RR in neonates in a non-contact fashion. The performance of radar measurements could be affected by neonate movement.
- Is Part Of:
- Royal Society open science. Volume 6:Issue 6(2019)
- Journal:
- Royal Society open science
- Issue:
- Volume 6:Issue 6(2019)
- Issue Display:
- Volume 6, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 6
- Issue:
- 6
- Issue Sort Value:
- 2019-0006-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-06-05
- Subjects:
- non-contact sensor -- impulse radio ultrawideband radar -- newborn -- respiratory rate -- neonatal intensive care unit
Science -- Periodicals
500 - Journal URLs:
- https://royalsocietypublishing.org/journal/rsos ↗
- DOI:
- 10.1098/rsos.190149 ↗
- Languages:
- English
- ISSNs:
- 2054-5703
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library STI - ELD Digital store
- Ingest File:
- 25047.xml