Small for gestational age is associated with reduced lung function in middle age: A prospective study from first to fifth decade of life. Issue 2 (5th October 2022)
- Record Type:
- Journal Article
- Title:
- Small for gestational age is associated with reduced lung function in middle age: A prospective study from first to fifth decade of life. Issue 2 (5th October 2022)
- Main Title:
- Small for gestational age is associated with reduced lung function in middle age: A prospective study from first to fifth decade of life
- Authors:
- Tandra, Melvin
Walters, E. Haydn
Perret, Jennifer
Lowe, Adrian J.
Lodge, Caroline J.
Johns, David P.
Thomas, Paul S.
Bowatte, Gayan
Davis, Peter G.
Abramson, Michael J.
Dharmage, Shyamali C.
Bui, Dinh S. - Abstract:
- Abstract: Background and Objective: The association between birth weight, particularly relative to gestational age, and adult lung function is uncertain. We investigated the associations between birth weight relative to gestational age and measures of lung function in middle age, and mediation of these associations by adult height. Methods: Participants in the Tasmanian Longitudinal Health Study who had both known birth weight and lung function assessment at age 45 years were included ( n = 849). Linear regression models were fitted to investigate the association between small for gestational age and birth weight with post‐bronchodilator lung function measures (forced expiratory volume in 1 second [FEV1 ], forced vital capacity [FVC], FEV1 /FVC, diffusing capacity for carbon monoxide [DL co], residual volume [RV] and total lung capacity [TLC]), adjusting for potential confounders. The contribution of adult height as a mediator of these associations was investigated. Results: Compared with infants born with normal weight for gestational age, those born small for gestational age had reduced FEV1 (coefficient: −191 ml [95%CI: −296, −87]), FVC (−205 ml [−330, −81]), TLC (−292 ml [−492, −92]), RV (−126 ml [−253, 0]) and DL co (−0.42 mmol/min/kPa [−0.79, −0.041]) at age 45 years. However, they had comparable FEV1 /FVC. For every 1 kg increase in birth weight, lung function indices increased by an average of 117 ml (95%CI: 40, 196) for FEV1, 124 ml (30, 218) for FVC, 215 ml (66,Abstract: Background and Objective: The association between birth weight, particularly relative to gestational age, and adult lung function is uncertain. We investigated the associations between birth weight relative to gestational age and measures of lung function in middle age, and mediation of these associations by adult height. Methods: Participants in the Tasmanian Longitudinal Health Study who had both known birth weight and lung function assessment at age 45 years were included ( n = 849). Linear regression models were fitted to investigate the association between small for gestational age and birth weight with post‐bronchodilator lung function measures (forced expiratory volume in 1 second [FEV1 ], forced vital capacity [FVC], FEV1 /FVC, diffusing capacity for carbon monoxide [DL co], residual volume [RV] and total lung capacity [TLC]), adjusting for potential confounders. The contribution of adult height as a mediator of these associations was investigated. Results: Compared with infants born with normal weight for gestational age, those born small for gestational age had reduced FEV1 (coefficient: −191 ml [95%CI: −296, −87]), FVC (−205 ml [−330, −81]), TLC (−292 ml [−492, −92]), RV (−126 ml [−253, 0]) and DL co (−0.42 mmol/min/kPa [−0.79, −0.041]) at age 45 years. However, they had comparable FEV1 /FVC. For every 1 kg increase in birth weight, lung function indices increased by an average of 117 ml (95%CI: 40, 196) for FEV1, 124 ml (30, 218) for FVC, 215 ml (66, 365) for TLC and 0.36 mmol/min/kPa (0.11, 0.62) for DL co, independent of gestational age, but again not for FEV1 /FVC. These associations were significantly mediated by adult height (56%–90%). Conclusion: Small for gestational age was associated with reduced lung function that is likely due to smaller lungs with little evidence of any specific parenchymal impairment. Abstract : Our study provides new evidence that small for gestational age is associated with reduced lung function consistent with a restrictive pattern in middle age. This suggests that the specific long‐term effect of reduced fetal lung growth relates to restrictive lung function pattern that is likely due to smaller lungs. See related Editorial … (more)
- Is Part Of:
- Respirology. Volume 28:Issue 2(2023)
- Journal:
- Respirology
- Issue:
- Volume 28:Issue 2(2023)
- Issue Display:
- Volume 28, Issue 2 (2023)
- Year:
- 2023
- Volume:
- 28
- Issue:
- 2
- Issue Sort Value:
- 2023-0028-0002-0000
- Page Start:
- 159
- Page End:
- 165
- Publication Date:
- 2022-10-05
- Subjects:
- adult lung function deficit -- low birth weight -- restriction -- small for gestational age -- spirometry -- Tasmanian Longitudinal Health Study
Respiratory organs -- Diseases -- Periodicals
Respiratory organs -- Periodicals
612.2 - Journal URLs:
- http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=res ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/resp.14379 ↗
- Languages:
- English
- ISSNs:
- 1323-7799
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7777.666000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25056.xml