Left ventricular myocardial deformation pattern, mechanical dispersion, and their relation with electrocardiogram markers in the large population-based STANISLAS cohort: insights into electromechanical coupling. (24th June 2020)
- Record Type:
- Journal Article
- Title:
- Left ventricular myocardial deformation pattern, mechanical dispersion, and their relation with electrocardiogram markers in the large population-based STANISLAS cohort: insights into electromechanical coupling. (24th June 2020)
- Main Title:
- Left ventricular myocardial deformation pattern, mechanical dispersion, and their relation with electrocardiogram markers in the large population-based STANISLAS cohort: insights into electromechanical coupling
- Authors:
- Verdugo-Marchese, Mario
Coiro, Stefano
Selton-Suty, Christine
Kobayashi, Masatake
Bozec, Erwan
Lamiral, Zohra
Venner, Clément
Zannad, Faiez
Rossignol, Patrick
Girerd, Nicolas
Huttin, Olivier - Abstract:
- Abstract: Aims : Mechanical alterations in patients with electrical conduction abnormalities are reported to have prognostic value in patients with left ventricular asynchrony or long QT syndrome beyond electrocardiogram (ECG) variables. Whether conduction and repolarization patterns derived from ECG are associated with speckle tracking echocardiography parameters in subjects without overt cardiac disease is yet to be investigated. To report ranges of longitudinal deformation according to conduction and repolarization values in a population-based cohort. Methods and results : One thousand, one hundred, and forty subjects (48.6 ± 14.0 years, 47.7% men) enrolled in the fourth visit of the STANISLAS cohort (Lorraine, France) were studied. Echocardiography strain was performed in all subjects. RR, PR, QRS, and QT intervals were retrieved from digitalized 12-lead ECG. Echocardiographic data were stratified according to quartiles of QRS and QTc duration values. Full-wall global longitudinal strain (GLS) was −21.1 ± 2.5% with a mechanical dispersion (MD) value of 34 ± 12 ms. Absolute GLS value was lower in the longest QRS quartile and shortest QTc quartile (both P < 0.001). Time-to-peak of strain was not significantly different according to QRS duration although significantly higher in patients with higher QTc ( P < 0.001). MD was significantly greater in patients with longer QTc (32 ± 12 ms for QTc < 396 ms vs. 36 ± 12 ms for QTc > 421 ms; P = 0.002). Conclusion : Longer QTc isAbstract: Aims : Mechanical alterations in patients with electrical conduction abnormalities are reported to have prognostic value in patients with left ventricular asynchrony or long QT syndrome beyond electrocardiogram (ECG) variables. Whether conduction and repolarization patterns derived from ECG are associated with speckle tracking echocardiography parameters in subjects without overt cardiac disease is yet to be investigated. To report ranges of longitudinal deformation according to conduction and repolarization values in a population-based cohort. Methods and results : One thousand, one hundred, and forty subjects (48.6 ± 14.0 years, 47.7% men) enrolled in the fourth visit of the STANISLAS cohort (Lorraine, France) were studied. Echocardiography strain was performed in all subjects. RR, PR, QRS, and QT intervals were retrieved from digitalized 12-lead ECG. Echocardiographic data were stratified according to quartiles of QRS and QTc duration values. Full-wall global longitudinal strain (GLS) was −21.1 ± 2.5% with a mechanical dispersion (MD) value of 34 ± 12 ms. Absolute GLS value was lower in the longest QRS quartile and shortest QTc quartile (both P < 0.001). Time-to-peak of strain was not significantly different according to QRS duration although significantly higher in patients with higher QTc ( P < 0.001). MD was significantly greater in patients with longer QTc (32 ± 12 ms for QTc < 396 ms vs. 36 ± 12 ms for QTc > 421 ms; P = 0.002). Conclusion : Longer QTc is related to increased MD and better longitudinal strain values. In a population-based setting, QRS is not associated with MD, suggesting that echocardiography-based dyssynchrony does not largely overlap with ECG-based dyssynchrony. … (more)
- Is Part Of:
- European heart journal. Volume 21:Number 11(2020)
- Journal:
- European heart journal
- Issue:
- Volume 21:Number 11(2020)
- Issue Display:
- Volume 21, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 21
- Issue:
- 11
- Issue Sort Value:
- 2020-0021-0011-0000
- Page Start:
- 1237
- Page End:
- 1245
- Publication Date:
- 2020-06-24
- Subjects:
- myocardial deformation -- left ventricle -- systolic function -- speckle tracking echocardiography -- population study -- mechanical dispersion -- electromechanical coupling
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.10754 - Journal URLs:
- http://ehjcimaging.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/jeaa148 ↗
- Languages:
- English
- ISSNs:
- 2047-2404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25085.xml