Magnetization Transfer BOOST Noncontrast Angiography Improves Pulmonary Vein Imaging in Adults With Congenital Heart Disease. Issue 2 (1st June 2022)
- Record Type:
- Journal Article
- Title:
- Magnetization Transfer BOOST Noncontrast Angiography Improves Pulmonary Vein Imaging in Adults With Congenital Heart Disease. Issue 2 (1st June 2022)
- Main Title:
- Magnetization Transfer BOOST Noncontrast Angiography Improves Pulmonary Vein Imaging in Adults With Congenital Heart Disease
- Authors:
- Rashid, Imran
Ginami, Giulia
Nordio, Giovanna
Fotaki, Anastasia
Neji, Radhouene
Alam, Harith
Pushparajah, Kuberan
Frigiola, Alessandra
Valverde, Israel
Botnar, René M.
Prieto, Claudia - Abstract:
- Abstract : Background: Cardiac MRI plays an important role in the diagnosis and follow‐up of patients with congenital heart disease (CHD). Gadolinium‐based contrast agents are often needed to overcome flow‐related and off‐resonance artifacts that can impair the quality of conventional noncontrast 3D imaging. As serial imaging is often required in CHD, the development of robust noncontrast 3D MRI techniques is desirable. Purpose: To assess the clinical utility of noncontrast enhanced magnetization transfer and inversion recovery prepared 3D free‐breathing sequence (MTC‐BOOST) compared to conventional 3D whole heart imaging in patients with CHD. Study type: Prospective, image quality. Population: A total of 27 adult patients (44% female, mean age 30.9 ± 14.8 years) with CHD. Field Strength/Sequence: A 1.5 T; free‐breathing 3D MTC‐BOOST sequence. Assessment: MTC‐BOOST was compared to diaphragmatic navigator‐gated, noncontrast T2 prepared 3D whole‐heart imaging sequence (T2prep‐3DWH) for comparison of vessel dimensions, lumen‐to‐myocardium contrast ratio (CR), and image quality (vessel wall sharpness and presence and type of artifacts) assessed by two experienced cardiologists on a 5‐point scale. Statistical Tests: Mann–Whitney test, paired Wilcoxon signed‐rank test, Bland–Altman plots. P < 0.05 was considered statistically significant. Results: MTC‐BOOST significantly improved image quality and CR of the right‐sided pulmonary veins (PV): (CR: right upper PV 1.06 ± 0.50 vs.Abstract : Background: Cardiac MRI plays an important role in the diagnosis and follow‐up of patients with congenital heart disease (CHD). Gadolinium‐based contrast agents are often needed to overcome flow‐related and off‐resonance artifacts that can impair the quality of conventional noncontrast 3D imaging. As serial imaging is often required in CHD, the development of robust noncontrast 3D MRI techniques is desirable. Purpose: To assess the clinical utility of noncontrast enhanced magnetization transfer and inversion recovery prepared 3D free‐breathing sequence (MTC‐BOOST) compared to conventional 3D whole heart imaging in patients with CHD. Study type: Prospective, image quality. Population: A total of 27 adult patients (44% female, mean age 30.9 ± 14.8 years) with CHD. Field Strength/Sequence: A 1.5 T; free‐breathing 3D MTC‐BOOST sequence. Assessment: MTC‐BOOST was compared to diaphragmatic navigator‐gated, noncontrast T2 prepared 3D whole‐heart imaging sequence (T2prep‐3DWH) for comparison of vessel dimensions, lumen‐to‐myocardium contrast ratio (CR), and image quality (vessel wall sharpness and presence and type of artifacts) assessed by two experienced cardiologists on a 5‐point scale. Statistical Tests: Mann–Whitney test, paired Wilcoxon signed‐rank test, Bland–Altman plots. P < 0.05 was considered statistically significant. Results: MTC‐BOOST significantly improved image quality and CR of the right‐sided pulmonary veins (PV): (CR: right upper PV 1.06 ± 0.50 vs. 0.58 ± 0.74; right lower PV 1.32 ± 0.38 vs. 0.81 ± 0.73) compared to conventional T2prep‐3DWH imaging where the PVs were not visualized in some cases due to off‐resonance effects. MTC‐BOOST demonstrated resistance to degradation of luminal signal (assessed by CR) secondary to accelerated or turbulent flow conditions. T2prep‐3DWH had higher image quality scores than MTC‐BOOST for the aorta and coronary arteries; however, great vessel dimensions derived from MTC‐BOOST showed excellent agreement with standard T2prep‐3DWH imaging. Data Conclusion: MTC‐BOOST allows for improved contrast‐free imaging of pulmonary veins and regions characterized by accelerated or turbulent blood flow compared to standard T2prep‐3DWH imaging, with excellent agreement of great vessel dimensions. Evidence Level: 1 Technical Efficacy: Stage 2 … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 57:Issue 2(2023)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 57:Issue 2(2023)
- Issue Display:
- Volume 57, Issue 2 (2023)
- Year:
- 2023
- Volume:
- 57
- Issue:
- 2
- Issue Sort Value:
- 2023-0057-0002-0000
- Page Start:
- 521
- Page End:
- 531
- Publication Date:
- 2022-06-01
- Subjects:
- magnetization Transfer -- MTC‐BOOST -- 3D whole heart imaging -- congenital heart disease
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.28280 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25077.xml