The utility of two-dimensional real-time shear wave elastography for assessing liver fibrosis in patients with chronic hepatitis C virus infection. Issue 11 (November 2021)
- Record Type:
- Journal Article
- Title:
- The utility of two-dimensional real-time shear wave elastography for assessing liver fibrosis in patients with chronic hepatitis C virus infection. Issue 11 (November 2021)
- Main Title:
- The utility of two-dimensional real-time shear wave elastography for assessing liver fibrosis in patients with chronic hepatitis C virus infection
- Authors:
- Numao, Hiroshi
Shimaya, Koji
Kakuta, Akihisa
Shibutani, Koichi
Igarashi, Syohei
Hasui, Keisuke
Hanabata, Norihiro
Kanazawa, Kosuke
Munakata, Masaki - Abstract:
- Abstract : Objective: Two-dimensional shear wave elastography (2D-SWE) is a new ultrasound-based elastography method to evaluate liver fibrosis in the daily practice. However, the utility of 2D-SWE among the other liver fibrosis markers is unclear. Methods: We enrolled 141 consecutive patients with hepatitis C virus infection, 66 men and 75 women (median age, 67 years), who underwent liver biopsy and 2D-SWE (LOGIQ E9, GE Healthcare, Wauwatosa, WI, USA). We compared the diagnostic accuracy of the 2D-SWE with those of magnetic resonance elastography (MRE; MR-Touch, GE Healthcare, Milwaukee, WI, USA), Mac-2 binding protein glycosylation isomer (M2BPGi), fibrosis-4 index (FIB-4) and platelet counts (PLT), using the histologic METAVIR scoring as the reference standard. Results: The areas under the receiver operating characteristics curves (AUROCs) of 2D-SWE, MRE, M2BPGi, FIB-4 and PLT for ≥F2, ≥F3 and F4 were 0.86, 0.88, 0.79, 0.81 and 0.77; 0.92, 0.93, 0.86, 0.87 and 0.83; and 0.91, 0.97, 0.85, 0.85 and 0.82, respectively. For diagnosing ≥F2 and ≥F3, the AUROCs of 2D-SWE and those of MRE showed no significant differences, and both 2D-SWE and MRE showed significantly higher AUROCs than the other markers. For diagnosing F4, the AUROC of MRE was significantly higher than those of other fibrosis markers. Conclusion: 2D-SWE has an excellent diagnostic accuracy equivalent to that of MRE for assessing significant (≥F2) and severe (≥F3) fibrosis. MRE demonstrated a higher AUROC thanAbstract : Objective: Two-dimensional shear wave elastography (2D-SWE) is a new ultrasound-based elastography method to evaluate liver fibrosis in the daily practice. However, the utility of 2D-SWE among the other liver fibrosis markers is unclear. Methods: We enrolled 141 consecutive patients with hepatitis C virus infection, 66 men and 75 women (median age, 67 years), who underwent liver biopsy and 2D-SWE (LOGIQ E9, GE Healthcare, Wauwatosa, WI, USA). We compared the diagnostic accuracy of the 2D-SWE with those of magnetic resonance elastography (MRE; MR-Touch, GE Healthcare, Milwaukee, WI, USA), Mac-2 binding protein glycosylation isomer (M2BPGi), fibrosis-4 index (FIB-4) and platelet counts (PLT), using the histologic METAVIR scoring as the reference standard. Results: The areas under the receiver operating characteristics curves (AUROCs) of 2D-SWE, MRE, M2BPGi, FIB-4 and PLT for ≥F2, ≥F3 and F4 were 0.86, 0.88, 0.79, 0.81 and 0.77; 0.92, 0.93, 0.86, 0.87 and 0.83; and 0.91, 0.97, 0.85, 0.85 and 0.82, respectively. For diagnosing ≥F2 and ≥F3, the AUROCs of 2D-SWE and those of MRE showed no significant differences, and both 2D-SWE and MRE showed significantly higher AUROCs than the other markers. For diagnosing F4, the AUROC of MRE was significantly higher than those of other fibrosis markers. Conclusion: 2D-SWE has an excellent diagnostic accuracy equivalent to that of MRE for assessing significant (≥F2) and severe (≥F3) fibrosis. MRE demonstrated a higher AUROC than 2D-SWE, but this last one has advantages such as lower cost, fewer contraindications and greater ease of performance than MRE. … (more)
- Is Part Of:
- European journal of gastroenterology & hepatology. Volume 33:Issue 11(2021)
- Journal:
- European journal of gastroenterology & hepatology
- Issue:
- Volume 33:Issue 11(2021)
- Issue Display:
- Volume 33, Issue 11 (2021)
- Year:
- 2021
- Volume:
- 33
- Issue:
- 11
- Issue Sort Value:
- 2021-0033-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-11
- Subjects:
- biomarker -- diagnostic accuracy -- hepatitis C virus -- liver fibrosis -- shear wave elastography
Digestive organs -- Diseases -- Periodicals
Liver -- Diseases -- Periodicals
Digestive organs -- Diseases
Liver -- Diseases
Periodicals
616.33 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00042737-000000000-00000 ↗
http://www.eurojgh.com/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/MEG.0000000000001887 ↗
- Languages:
- English
- ISSNs:
- 0954-691X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.729400
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25070.xml