Test-Retest Reliability and Minimal Detectable Change of the Instrumented Modified Clinical Test of Sensory Interaction on Balance in Healthy, Older Adults. Issue 4 (October 2021)
- Record Type:
- Journal Article
- Title:
- Test-Retest Reliability and Minimal Detectable Change of the Instrumented Modified Clinical Test of Sensory Interaction on Balance in Healthy, Older Adults. Issue 4 (October 2021)
- Main Title:
- Test-Retest Reliability and Minimal Detectable Change of the Instrumented Modified Clinical Test of Sensory Interaction on Balance in Healthy, Older Adults
- Authors:
- Watson, Seth
Trudelle-Jackson, Elaine - Abstract:
- Abstract : Background and Purpose: Test-retest reliability has not been previously reported for the instrumented modified Clinical Test of Sensory Interaction on Balance (i-mCTSIB) utilizing the Neurocom Very Simple Rehab (VSR) Sport force plate. The VSR Sport is a portable, relatively inexpensive force plate system utilized to assess postural stability in various populations. Therefore, the purpose of this study is to determine the test-retest reliability, standard error of measurement (SEM), and minimal detectable change (MDC) of the i-mCTSIB when assessed using the VSR Sport in a sample of healthy, older adults. Methods: This was a methodological study with 20 healthy, older adults between the ages of 65 and 85 years. Participants were tested twice in a single session on the i-mCTSIB utilizing the VSR Sport force plate. The mean sway velocity (°/s) measurements for the 2 trials were compared for each test condition to compute intraclass correlation coefficients (ICCs) for each measurement. Standard error of measurements and minimal detectable change at the 90% confidence level (MDC90 ) were also calculated. Results and Discussion: The test-retest reliability for each of the test conditions ranged from 0.762 to 0.909, which can be broadly interpreted as good-to-excellent reliability. The ICC(2, k) value of 0.898 for the composite score can also be interpreted as excellent reliability. Our results revealed small SEM for all test conditions (SEM = 0.060-0.101) except for theAbstract : Background and Purpose: Test-retest reliability has not been previously reported for the instrumented modified Clinical Test of Sensory Interaction on Balance (i-mCTSIB) utilizing the Neurocom Very Simple Rehab (VSR) Sport force plate. The VSR Sport is a portable, relatively inexpensive force plate system utilized to assess postural stability in various populations. Therefore, the purpose of this study is to determine the test-retest reliability, standard error of measurement (SEM), and minimal detectable change (MDC) of the i-mCTSIB when assessed using the VSR Sport in a sample of healthy, older adults. Methods: This was a methodological study with 20 healthy, older adults between the ages of 65 and 85 years. Participants were tested twice in a single session on the i-mCTSIB utilizing the VSR Sport force plate. The mean sway velocity (°/s) measurements for the 2 trials were compared for each test condition to compute intraclass correlation coefficients (ICCs) for each measurement. Standard error of measurements and minimal detectable change at the 90% confidence level (MDC90 ) were also calculated. Results and Discussion: The test-retest reliability for each of the test conditions ranged from 0.762 to 0.909, which can be broadly interpreted as good-to-excellent reliability. The ICC(2, k) value of 0.898 for the composite score can also be interpreted as excellent reliability. Our results revealed small SEM for all test conditions (SEM = 0.060-0.101) except for the foam surface, eyes closed condition, with an SEM of 0.481. The MDC90 results for all testing conditions ranged from 0.140 to 0.285 except for the foam surface, eyes closed condition, which had an MDC90 = 1.12. Conclusions: The i-mCTSIB measurements utilizing the VSR Sport demonstrated good-to-excellent test-retest reliability. The clinical relevance of this study is that it demonstrates that the VSR Sport is a feasible alternative to other more expensive computerized systems used for the assessment of postural sway. MDC90 scores allow interpretation of change in i-mCTSIB scores following intervention. Practice effects may have contributed to the larger MDC90 for sway scores in the foam surface, eyes closed condition. … (more)
- Is Part Of:
- Journal of geriatric physical therapy. Volume 44:Issue 4(2021)
- Journal:
- Journal of geriatric physical therapy
- Issue:
- Volume 44:Issue 4(2021)
- Issue Display:
- Volume 44, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 44
- Issue:
- 4
- Issue Sort Value:
- 2021-0044-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10
- Subjects:
- fall risk -- mCTSIB -- postural control -- screening
Physical therapy for older people -- Periodicals
Older people -- Orientation and mobility -- Periodicals
Older people -- Health and hygiene -- Periodicals
Geriatrics -- Periodicals
615.820846 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00139143-000000000-00000 ↗
http://journals.lww.com/jgpt/pages/default.aspx ↗
http://www.jgpt.org ↗
http://journals.lww.com ↗ - DOI:
- 10.1519/JPT.0000000000000274 ↗
- Languages:
- English
- ISSNs:
- 1539-8412
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4995.074000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25069.xml