1.5 vs 3 Tesla Magnetic Resonance Imaging: A Review of Favorite Clinical Applications for Both Field Strengths—Part 1. Issue 11 (November 2021)
- Record Type:
- Journal Article
- Title:
- 1.5 vs 3 Tesla Magnetic Resonance Imaging: A Review of Favorite Clinical Applications for Both Field Strengths—Part 1. Issue 11 (November 2021)
- Main Title:
- 1.5 vs 3 Tesla Magnetic Resonance Imaging
- Authors:
- Schick, Fritz
Pieper, Claus Christian
Kupczyk, Patrick
Almansour, Haidara
Keller, Gabriel
Springer, Fabian
Mürtz, Petra
Endler, Christoph
Sprinkart, Alois M.
Kaufmann, Sascha
Herrmann, Judith
Attenberger, Ulrike I. - Abstract:
- Abstract : Abstract: Whole-body magnetic resonance imaging (MRI) systems with a field strength of 3 T have been offered by all leading manufacturers for approximately 2 decades and are increasingly used in clinical diagnostics despite higher costs. Technologically, MRI systems operating at 3 T have reached a high standard in recent years, as well as the 1.5-T devices that have been in use for a longer time. For modern MRI systems with 3 T, more complexity is required, especially for the magnet and the radiofrequency (RF) system (with multichannel transmission). Many clinical applications benefit greatly from the higher field strength due to the higher signal yield (eg, imaging of the brain or extremities), but there are also applications where the disadvantages of 3 T might outweigh the advantages (eg, lung imaging or examinations in the presence of implants). This review describes some technical features of modern 1.5-T and 3-T whole-body MRI systems, and reports on the experience of using both types of devices in different clinical settings, with all sections written by specialist radiologists in the respective fields. This first part of the review includes an overview of the general physicotechnical aspects of both field strengths and elaborates the special conditions of diffusion imaging. Many relevant aspects in the application areas of musculoskeletal imaging, abdominal imaging, and prostate diagnostics are discussed.
- Is Part Of:
- Investigative radiology. Volume 56:Issue 11(2021)
- Journal:
- Investigative radiology
- Issue:
- Volume 56:Issue 11(2021)
- Issue Display:
- Volume 56, Issue 11 (2021)
- Year:
- 2021
- Volume:
- 56
- Issue:
- 11
- Issue Sort Value:
- 2021-0056-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-11
- Subjects:
- 1.5 T -- 3 T -- magnetic resonance imaging -- magnetic field strength -- MRI: physical basics -- MRI: DWI -- musculoskeletal imaging -- abdominal imaging -- prostate imaging
Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000812 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25072.xml