A detachable configuration for the precast beam-column connection using metallic damper as connector: Experimental investigation. (15th April 2023)
- Record Type:
- Journal Article
- Title:
- A detachable configuration for the precast beam-column connection using metallic damper as connector: Experimental investigation. (15th April 2023)
- Main Title:
- A detachable configuration for the precast beam-column connection using metallic damper as connector: Experimental investigation
- Authors:
- Wu, Congxiao
Zhu, Chunyuan
Li, Dingbin
Li, Changhong
Zhou, Yun
Lie, Wenchen
Wu, Congyong
Chen, Zhangyan - Abstract:
- Abstract: A beam-column connection with satisfactory seismic performance and assembly efficiency is preferred in prefabricated structures. An evolved detachable configuration for the precast beam-column connection using metallic damper as connector (PCF-MDC-nuts) is proposed. The detachable connection significantly reduces the labor cost of building demolition, repair, and recycling. A specimen PCF-MDC-nuts was designed and constructed based on a precast "wet" connection (specimen PC)). A dog-bone damper was adopted in PCF-MDC-nuts as a sacrificial element. First, a laboratory test was performed on the damper, followed by the beam-column connection. The dominant failure pattern of the dog-bone damper, both in the damper and connection tests, was mainly out-of-plane flexural-torsional buckling. The test results show that PCF-MDC-nuts has a similar flexural strength as PC. The maximum in-elastic drift ratio of PCF-MDC-nuts has been improved to 5.48% compared to that of PC (3.27%). The degradation of PC-MDC-nuts was alleviated compared with PC. The cumulated absorbed energy and maximum equivalent viscous damping ratio of the PCF-MDC-nuts were 41.04 kN·m and 44.17%, respectively, while those of PC were 11.06 kN·m and 19.48%. The seismic performance of PCF-MDC-nuts was superior to PC. The concept of the proposed detachable configuration was justified. Highlights: A detachable configuration for the precast beam-column connection was proposed. The assembly efficiency and seismicAbstract: A beam-column connection with satisfactory seismic performance and assembly efficiency is preferred in prefabricated structures. An evolved detachable configuration for the precast beam-column connection using metallic damper as connector (PCF-MDC-nuts) is proposed. The detachable connection significantly reduces the labor cost of building demolition, repair, and recycling. A specimen PCF-MDC-nuts was designed and constructed based on a precast "wet" connection (specimen PC)). A dog-bone damper was adopted in PCF-MDC-nuts as a sacrificial element. First, a laboratory test was performed on the damper, followed by the beam-column connection. The dominant failure pattern of the dog-bone damper, both in the damper and connection tests, was mainly out-of-plane flexural-torsional buckling. The test results show that PCF-MDC-nuts has a similar flexural strength as PC. The maximum in-elastic drift ratio of PCF-MDC-nuts has been improved to 5.48% compared to that of PC (3.27%). The degradation of PC-MDC-nuts was alleviated compared with PC. The cumulated absorbed energy and maximum equivalent viscous damping ratio of the PCF-MDC-nuts were 41.04 kN·m and 44.17%, respectively, while those of PC were 11.06 kN·m and 19.48%. The seismic performance of PCF-MDC-nuts was superior to PC. The concept of the proposed detachable configuration was justified. Highlights: A detachable configuration for the precast beam-column connection was proposed. The assembly efficiency and seismic performance of the novel connection is satisfactory. The detachable configuration is reliable and feasible. The energy-absorption capacity of the novel connection is improved. … (more)
- Is Part Of:
- Journal of building engineering. Volume 65(2023)
- Journal:
- Journal of building engineering
- Issue:
- Volume 65(2023)
- Issue Display:
- Volume 65, Issue 2023 (2023)
- Year:
- 2023
- Volume:
- 65
- Issue:
- 2023
- Issue Sort Value:
- 2023-0065-2023-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-04-15
- Subjects:
- Earthquake -- Precast beam-column connection -- Metallic damper -- Seismic performance -- Quasi-static test
Building -- Periodicals
690.05 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23527102 ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.jobe.2022.105597 ↗
- Languages:
- English
- ISSNs:
- 2352-7102
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25080.xml