Dynamic reaction picklist for improving allergy reaction documentation: A usability study. (February 2023)
- Record Type:
- Journal Article
- Title:
- Dynamic reaction picklist for improving allergy reaction documentation: A usability study. (February 2023)
- Main Title:
- Dynamic reaction picklist for improving allergy reaction documentation: A usability study
- Authors:
- Wang, Liqin
Park, Heekyong
Vallamkonda, Sachin
Seger, Diane L.
Blackley, Suzanne V.
Garabedian, Pamela M.
Goss, Foster
Blumenthal, Kimberly G.
Bates, David W.
Murphy, Shawn
Zhou, Li - Abstract:
- Highlights: Dynamic reaction picklists significantly reduced the number of free-text entries. Dynamic reaction picklists could reduce the time for allergy documentation by 15%. Clinicians preferred dynamic reaction picklist over static picklist. Abstract: Objective: To assess novel dynamic reaction picklists for improving allergy reaction documentation compared to a static reaction picklist. Materials and methods: We developed three web-based user interfaces (UIs) mimicking the Mass General Brigham's EHR allergy module: the first and second UIs (i.e., UI-1D, UI-2D) implemented two dynamic reaction picklists with different ranking algorithms and the third UI (UI-3S) implemented a static reaction picklist like the one used in the current EHR. We recruited 18 clinicians to perform allergy entry for 10 test cases each via UI-1D and UI-3S, and another 18 clinicians via UI-2D and UI-3S. Primary measures were the number of free-text entries and time to complete the allergy entry. Clinicians were also interviewed using 30 questions before and after the data entry. Results and discussions: Among 36 clinicians, less than half were satisfied with the current EHR reaction picklists, due to their incomprehensiveness, inefficiency, and lack of intuitiveness. The clinicians used significantly fewer free-text entries when using UI-1D or UI-2D compared to UI-3S ( p < 0.05). The clinicians used on average 51 s (15 %) less time via UI-1D and 50 s (16 %) less time via UI-2D in completing theHighlights: Dynamic reaction picklists significantly reduced the number of free-text entries. Dynamic reaction picklists could reduce the time for allergy documentation by 15%. Clinicians preferred dynamic reaction picklist over static picklist. Abstract: Objective: To assess novel dynamic reaction picklists for improving allergy reaction documentation compared to a static reaction picklist. Materials and methods: We developed three web-based user interfaces (UIs) mimicking the Mass General Brigham's EHR allergy module: the first and second UIs (i.e., UI-1D, UI-2D) implemented two dynamic reaction picklists with different ranking algorithms and the third UI (UI-3S) implemented a static reaction picklist like the one used in the current EHR. We recruited 18 clinicians to perform allergy entry for 10 test cases each via UI-1D and UI-3S, and another 18 clinicians via UI-2D and UI-3S. Primary measures were the number of free-text entries and time to complete the allergy entry. Clinicians were also interviewed using 30 questions before and after the data entry. Results and discussions: Among 36 clinicians, less than half were satisfied with the current EHR reaction picklists, due to their incomprehensiveness, inefficiency, and lack of intuitiveness. The clinicians used significantly fewer free-text entries when using UI-1D or UI-2D compared to UI-3S ( p < 0.05). The clinicians used on average 51 s (15 %) less time via UI-1D and 50 s (16 %) less time via UI-2D in completing the allergy entries versus UI-3S, and there was not a statistically significant difference in documentation time for either group between the dynamic and static UIs. Overall, 15–17 (83–94 %) clinicians rated UI-1D and 13–15 (72–83 %) clinicians rated UI-2D as efficient, easy to use, and useful, while less than half rated the same for UI-3S. Most clinicians reported that the dynamic reaction picklists always or often suggested appropriate reactions (n = 30, 83 %) and would decrease the free-text entries (n = 26, 72 %); nearly all preferred the dynamic picklist over the static picklist (n = 32, 89 %). Conclusion: We found that dynamic reaction picklists significantly reduced the number of free-text entries and could reduce the time for allergy documentation by 15%. Clinicians preferred the dynamic reaction picklist over the static picklist. … (more)
- Is Part Of:
- International journal of medical informatics. Volume 170(2023)
- Journal:
- International journal of medical informatics
- Issue:
- Volume 170(2023)
- Issue Display:
- Volume 170, Issue 2023 (2023)
- Year:
- 2023
- Volume:
- 170
- Issue:
- 2023
- Issue Sort Value:
- 2023-0170-2023-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-02
- Subjects:
- Drug hypersensitivity -- Drug-related side effects and adverse reactions -- Electronic health record -- Documentation -- User interface evaluation -- Usability
EHR Electronic Health Record -- CDS Clinical Decision Support -- TFIDF Term Frequency Inverse Document Frequency -- MGB Mass General Brigham -- UI User Interface
Medical informatics -- Periodicals
Information science -- Periodicals
Computers -- Periodicals
Medical technology -- Periodicals
Medical Informatics -- Periodicals
Technology, Medical -- Periodicals
Computers
Information science
Medical informatics
Medical technology
Electronic journals
Periodicals
Electronic journals
610.285 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13865056 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13865056 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13865056 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijmedinf.2022.104939 ↗
- Languages:
- English
- ISSNs:
- 1386-5056
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.345250
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25645.xml