A markerless beam's eye view tumor tracking algorithm based on unsupervised deformable registration learning framework of VoxelMorph in medical image with partial data. (January 2023)
- Record Type:
- Journal Article
- Title:
- A markerless beam's eye view tumor tracking algorithm based on unsupervised deformable registration learning framework of VoxelMorph in medical image with partial data. (January 2023)
- Main Title:
- A markerless beam's eye view tumor tracking algorithm based on unsupervised deformable registration learning framework of VoxelMorph in medical image with partial data
- Authors:
- Zhong, Jiajian
Huang, Taiming
Qiu, Minmin
Guan, Qi
Luo, Ning
Deng, Yongjin - Abstract:
- Highlights: Propose a markerless BEV tumor radiotherapy tracking algorithm. Requires no additional equipment; free of secondary trauma and additional dose. Achieve the alignment of MLC occlusion images with template matching method. End-to-end unsupervised framework for non-rigid registration of partial image data. Processes inferior quality MV X-ray images with high noise level and low contrast. Abstract: Purpose: To propose an unsupervised deformable registration learning framework-based markerless beam's eye view (BEV) tumor tracking algorithm for the inferior quality megavolt (MV) images with occlusion and deformation. Methods: Quality assurance (QA) plans for thorax phantom were delivered to the linear accelerator with artificially treatment offsets. Electronic portal imaging device (EPID) images (682 in total) and corresponding digitally reconstructed radiograph (DRR) were gathered as the moving and fixed image pairs, which were randomly divided into training and testing set in a ratio of 0.7:0.3 to train a non-rigid registration model with Voxelmorph. Simultaneously, 533 pairs of patient images from 21 lung tumor plans were acquired for tumor tracking investigation to offer quantifiable tumor motion data. Tracking error and image similarity measures were employed to evaluate the algorithm's accuracy. Results: The tracking algorithm can handle image registration with non-rigid deformation and losses ranging from 10 % to 80 %. The tracking errors in the phantom studyHighlights: Propose a markerless BEV tumor radiotherapy tracking algorithm. Requires no additional equipment; free of secondary trauma and additional dose. Achieve the alignment of MLC occlusion images with template matching method. End-to-end unsupervised framework for non-rigid registration of partial image data. Processes inferior quality MV X-ray images with high noise level and low contrast. Abstract: Purpose: To propose an unsupervised deformable registration learning framework-based markerless beam's eye view (BEV) tumor tracking algorithm for the inferior quality megavolt (MV) images with occlusion and deformation. Methods: Quality assurance (QA) plans for thorax phantom were delivered to the linear accelerator with artificially treatment offsets. Electronic portal imaging device (EPID) images (682 in total) and corresponding digitally reconstructed radiograph (DRR) were gathered as the moving and fixed image pairs, which were randomly divided into training and testing set in a ratio of 0.7:0.3 to train a non-rigid registration model with Voxelmorph. Simultaneously, 533 pairs of patient images from 21 lung tumor plans were acquired for tumor tracking investigation to offer quantifiable tumor motion data. Tracking error and image similarity measures were employed to evaluate the algorithm's accuracy. Results: The tracking algorithm can handle image registration with non-rigid deformation and losses ranging from 10 % to 80 %. The tracking errors in the phantom study were below 3 mm in about 86.8 % of cases, and below 2 mm in about 80 % of cases. The normalized mutual information (NMI) changes from 1.182 ± 0.024 to 1.198 ± 0.024 (p < 0.005). The patient target had an average translation of 3.784 mm and a maximum comprehensive displacement value of 7.455 mm. NMI of patient images changes from 1.209 ± 0.027 to 1.217 ± 0.026 (p < 0.005), indicating the presence of non-negligible non-rigid deformation. Conclusions: The study provides a robust markerless tumor tracking algorithm for multi-modal, partial data and inferior quality image processing. … (more)
- Is Part Of:
- Physica medica. Volume 105(2023)
- Journal:
- Physica medica
- Issue:
- Volume 105(2023)
- Issue Display:
- Volume 105, Issue 2023 (2023)
- Year:
- 2023
- Volume:
- 105
- Issue:
- 2023
- Issue Sort Value:
- 2023-0105-2023-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-01
- Subjects:
- Markerless tumor tracking -- EPID -- Unsupervised -- Missing data
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2022.12.002 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25641.xml