PP-023 Evaluation of the performance of an automated system for the preparation of cytotoxic bags. (24th March 2015)
- Record Type:
- Journal Article
- Title:
- PP-023 Evaluation of the performance of an automated system for the preparation of cytotoxic bags. (24th March 2015)
- Main Title:
- PP-023 Evaluation of the performance of an automated system for the preparation of cytotoxic bags
- Authors:
- Verrey, A
Carrez, L
Falaschi, L
Bouchoud, L
Bonnabry, P - Abstract:
- Abstract : Background: The increased use of chemotherapy drugs forces hospitals to rationalise their production. Automated systems are one of the possible solutions. Purpose: To evaluate the performance of the PharmaHelp (Fresenius) automated system for accuracy (trueness and repeatability) and productivity comparing different working conditions. Material and methods: Accuracy was studied by automated filling of 10 different volumes of IV bags from 0.5 to 250 mL. Working conditions studied were the filling position, size of syringes (20/60 mL), working day and manufacturing methods (dose banding/individualised doses). Gravimetric and chemical analyses (phenylephrine as tracer) were used for the measure of accuracy. Productivity was evaluated by the production time for batches of 10 IV bags of different filling volumes. Results were discussed according to accuracy limits of ±3%, ±5%, ±10% (IC95). Results: The filling was true for all studied volumes (97–103%). The minimum volumes allowing accurate preparation were 100, 3 and 1 mL in the limits of 3%, 5% and 10%, respectively. The repeatability was not influenced by the filling position (Student's t-test, p = 0.36, n = 180) or the working day (Student's t-test, p = 0.14 day 1/2, p = 0.46 day 1/3, p = 0.09 day 2/3, n = 540). Accuracy was the same for the 2 manufacturing methods (Student's t-test, p = 0.12, n = 360 (individualised doses), n = 180 (dose-banding)) and the 2 sizes of syringes (Student's t-test, p = 0.46, n = 270).Abstract : Background: The increased use of chemotherapy drugs forces hospitals to rationalise their production. Automated systems are one of the possible solutions. Purpose: To evaluate the performance of the PharmaHelp (Fresenius) automated system for accuracy (trueness and repeatability) and productivity comparing different working conditions. Material and methods: Accuracy was studied by automated filling of 10 different volumes of IV bags from 0.5 to 250 mL. Working conditions studied were the filling position, size of syringes (20/60 mL), working day and manufacturing methods (dose banding/individualised doses). Gravimetric and chemical analyses (phenylephrine as tracer) were used for the measure of accuracy. Productivity was evaluated by the production time for batches of 10 IV bags of different filling volumes. Results were discussed according to accuracy limits of ±3%, ±5%, ±10% (IC95). Results: The filling was true for all studied volumes (97–103%). The minimum volumes allowing accurate preparation were 100, 3 and 1 mL in the limits of 3%, 5% and 10%, respectively. The repeatability was not influenced by the filling position (Student's t-test, p = 0.36, n = 180) or the working day (Student's t-test, p = 0.14 day 1/2, p = 0.46 day 1/3, p = 0.09 day 2/3, n = 540). Accuracy was the same for the 2 manufacturing methods (Student's t-test, p = 0.12, n = 360 (individualised doses), n = 180 (dose-banding)) and the 2 sizes of syringes (Student's t-test, p = 0.46, n = 270). The production time depended on the injected volume and the size of the syringe. The production of 10 bags took 45 ± 112 min on average, 30% for the manual steps (pre-processing: 24%, post-processing: 6%) and 70% for the automated step. Conclusion: The automated system produced IV bags from liquid active components. The filling was accurate from a volume of 3 mL for <±5% and 1 mL for <±10% limits. Results confirmed the potential of such automated systems to increase productivity and to guarantee the safety of patients and operators. References and/or acknowledgements: No conflict of interest. … (more)
- Is Part Of:
- European journal of hospital pharmacy. Volume 22(2015)Supplement 1
- Journal:
- European journal of hospital pharmacy
- Issue:
- Volume 22(2015)Supplement 1
- Issue Display:
- Volume 22, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 22
- Issue:
- 1
- Issue Sort Value:
- 2015-0022-0001-0000
- Page Start:
- A125
- Page End:
- A126
- Publication Date:
- 2015-03-24
- Subjects:
- Pharmacy -- Periodicals
Hospital pharmacies -- Periodicals
615.1 - Journal URLs:
- http://www.bmj.com/archive ↗
http://ejhp.bmj.com/ ↗ - DOI:
- 10.1136/ejhpharm-2015-000639.303 ↗
- Languages:
- English
- ISSNs:
- 2047-9956
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 25025.xml