Mitigation effect of cell exclusion on blood damage in spiral groove bearings. (January 2023)
- Record Type:
- Journal Article
- Title:
- Mitigation effect of cell exclusion on blood damage in spiral groove bearings. (January 2023)
- Main Title:
- Mitigation effect of cell exclusion on blood damage in spiral groove bearings
- Authors:
- Chan, Chris Hoi Houng
Murashige, Tomotaka
Bieritz, Shelby A.
Semenzin, Clayton
Smith, Amanda
Leslie, Laura
Simmonds, Michael J.
Tansley, Geoff D. - Abstract:
- Abstract: Cell exclusion in spiral groove bearing (SGB) excludes red blood cells from high shear regions in the bearing gaps and potentially reduce haemolysis in rotary blood pumps. However, this mechanobiological phenomenon has been observed in ultra-low blood haematocrit only, whether it can mitigate blood damage in a clinically-relevant blood haematocrit remains unknown. This study examined whether cell exclusion in a SGB alters haemolysis and/or high-molecular-weight von Willebrand factor (HMW vWF) multimer degradation. Citrated human blood was adjusted to 35 % haematocrit and exposed to a SGB (n = 6) and grooveless disc (n = 3, as a non-cell exclusion control) incorporated into a custom-built Couette test rig operating at 2000RPM for an hour; shearing gaps were 20, 30, and 40 μm. Haemolysis was assessed via spectrophotometry and HMW vWF multimer degradation was detected with gel electrophoresis and immunoblotting. Haemolysis caused by the SGB at gaps of 20, 30 and 40 μm were 10.6 ± 3.3, 9.6 ± 2.7 and 10.5 ± 3.9 mg/dL.hr compared to 23.3 ± 2.6, 12.8 ± 3.2, 9.8 ± 1.8 mg/dL.hr by grooveless disc. At the same shearing gap of 20 µm, there was a significant reduced in haemolysis (P = 0.0001) and better preserved in HMW vWF multimers (p < 0.05) when compared SGB to grooveless disc. The reduction in blood damage in the SGB compared to grooveless disc is indicative of cell exclusion occurred at the gap of 20 µm. This is the first experimental study to demonstrate that cellAbstract: Cell exclusion in spiral groove bearing (SGB) excludes red blood cells from high shear regions in the bearing gaps and potentially reduce haemolysis in rotary blood pumps. However, this mechanobiological phenomenon has been observed in ultra-low blood haematocrit only, whether it can mitigate blood damage in a clinically-relevant blood haematocrit remains unknown. This study examined whether cell exclusion in a SGB alters haemolysis and/or high-molecular-weight von Willebrand factor (HMW vWF) multimer degradation. Citrated human blood was adjusted to 35 % haematocrit and exposed to a SGB (n = 6) and grooveless disc (n = 3, as a non-cell exclusion control) incorporated into a custom-built Couette test rig operating at 2000RPM for an hour; shearing gaps were 20, 30, and 40 μm. Haemolysis was assessed via spectrophotometry and HMW vWF multimer degradation was detected with gel electrophoresis and immunoblotting. Haemolysis caused by the SGB at gaps of 20, 30 and 40 μm were 10.6 ± 3.3, 9.6 ± 2.7 and 10.5 ± 3.9 mg/dL.hr compared to 23.3 ± 2.6, 12.8 ± 3.2, 9.8 ± 1.8 mg/dL.hr by grooveless disc. At the same shearing gap of 20 µm, there was a significant reduced in haemolysis (P = 0.0001) and better preserved in HMW vWF multimers (p < 0.05) when compared SGB to grooveless disc. The reduction in blood damage in the SGB compared to grooveless disc is indicative of cell exclusion occurred at the gap of 20 µm. This is the first experimental study to demonstrate that cell exclusion in a SGB mitigates the shear-induced blood damage in a clinically-relevant blood haematocrit of 35 %, which can be potentially utilised in future blood pump design. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 146(2023)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 146(2023)
- Issue Display:
- Volume 146, Issue 2023 (2023)
- Year:
- 2023
- Volume:
- 146
- Issue:
- 2023
- Issue Sort Value:
- 2023-0146-2023-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-01
- Subjects:
- Left ventricular assist device -- Spiral groove bearing -- Cell exclusion -- Haemolysis -- HMW vWF multimer degradation
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2022.111394 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25309.xml