929 LEADLESS PACEMAKER IMPLANTATION FOLLOWING TRANSVENOUS LEAD EXTRACTION: DATA FROM HIGH-VOLUME REFERRAL CENTERS. (15th December 2022)
- Record Type:
- Journal Article
- Title:
- 929 LEADLESS PACEMAKER IMPLANTATION FOLLOWING TRANSVENOUS LEAD EXTRACTION: DATA FROM HIGH-VOLUME REFERRAL CENTERS. (15th December 2022)
- Main Title:
- 929 LEADLESS PACEMAKER IMPLANTATION FOLLOWING TRANSVENOUS LEAD EXTRACTION: DATA FROM HIGH-VOLUME REFERRAL CENTERS
- Authors:
- Mitacchione, Gianfranco
Schiavone, Marco
Arabia, Gianmarco
Gasperetti, Alessio
Denora, Marialessia
Arosio, Roberto
Palmisano, Pietro
Montemerlo, Elisabetta
Manuel, Cerini
Russo, Giulia
Mazzone, Patrizio
Ziacchi, Matteo
Pisanò, Ennio
Rovaris, Giovanni
Gulletta, Simone
Steffel, Jan
De Asmundis, Carlo
Breitenstein, Alexander
Biffi, Mauro
Battista Chierchia, Giovanni
Dello Russo, Antonio
Bella, Paolo Della
Claudio, Tondo
Battista Forleo, Giovanni
Curnis, Antonio - Abstract:
- Abstract: Background: limited data on real-world safety and efficacy of leadless pacemakers (LPMs) in patients who underwent transvenous lead extraction (TLE) are currently available. The present study aims to assess long-term safety and efficacy of LPMs implantation following TLE, compared with LPM de novo implant patients. Methods: consecutive patients who underwent LPM implantation in 12 centers joining the International LEAdless PacemakEr (i-LEAPER) registry were enrolled end retrospectively considered. Patients receiving LPM following TLE (n=184) were compared with patients with de novo implant (n=995). The primary endpoint was LPM-related complications rate at implant and during follow-up (FU). Additionally, differences in electrical performance were assessed between the two groups. Results: 1179 patients were enrolled in this study and followed for a median of 33 months. LPM related major complications and all-cause mortality did not differ among the two groups (1.6% TLE group vs. 2.2% de novo group, p=0.785, and 5.4% TLE group vs . 7.8% de novo group, p=0.288, respectively). Pacing threshold (PT) resulted higher in the TLE group throughout the whole follow-up (FU) (Figure 1). Higher PTs were recorded in LPMs implanted at same location from where the previous transvenous lead was removed, as far as 24-months postimplant (Figure 2), with a higher proportion of patients with high PT (>1 to 2V @0.24ms) in the first group at implant, 1-month, and 12-month FU (Figure 3).Abstract: Background: limited data on real-world safety and efficacy of leadless pacemakers (LPMs) in patients who underwent transvenous lead extraction (TLE) are currently available. The present study aims to assess long-term safety and efficacy of LPMs implantation following TLE, compared with LPM de novo implant patients. Methods: consecutive patients who underwent LPM implantation in 12 centers joining the International LEAdless PacemakEr (i-LEAPER) registry were enrolled end retrospectively considered. Patients receiving LPM following TLE (n=184) were compared with patients with de novo implant (n=995). The primary endpoint was LPM-related complications rate at implant and during follow-up (FU). Additionally, differences in electrical performance were assessed between the two groups. Results: 1179 patients were enrolled in this study and followed for a median of 33 months. LPM related major complications and all-cause mortality did not differ among the two groups (1.6% TLE group vs. 2.2% de novo group, p=0.785, and 5.4% TLE group vs . 7.8% de novo group, p=0.288, respectively). Pacing threshold (PT) resulted higher in the TLE group throughout the whole follow-up (FU) (Figure 1). Higher PTs were recorded in LPMs implanted at same location from where the previous transvenous lead was removed, as far as 24-months postimplant (Figure 2), with a higher proportion of patients with high PT (>1 to 2V @0.24ms) in the first group at implant, 1-month, and 12-month FU (Figure 3). Conclusion: In this real-world registry, LPMs showed a satisfactory safety and efficacy profile after TLE. In the post-TLE cohort, better electrical parameters were obtained when LPMs were implanted at a different location from where the previous transvenous lead was extracted. … (more)
- Is Part Of:
- European heart journal supplements. Volume 24(2022)Supplement K
- Journal:
- European heart journal supplements
- Issue:
- Volume 24(2022)Supplement K
- Issue Display:
- Volume 24, Issue 11 (2022)
- Year:
- 2022
- Volume:
- 24
- Issue:
- 11
- Issue Sort Value:
- 2022-0024-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-12-15
- Subjects:
- Cardiology -- Periodicals
Cardiology -- Europe -- Periodicals
616.12005 - Journal URLs:
- http://eurheartjsupp.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartjsupp/suac121.058 ↗
- Languages:
- English
- ISSNs:
- 1520-765X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717510
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25023.xml