1032 FEASIBILITY AND RELIABILITY OF COMPREHENSIVE THREE DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY SCREENING PROCESS FOR TRANSCATHETER MITRAL VALVE REPLACEMENT. (15th December 2022)
- Record Type:
- Journal Article
- Title:
- 1032 FEASIBILITY AND RELIABILITY OF COMPREHENSIVE THREE DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY SCREENING PROCESS FOR TRANSCATHETER MITRAL VALVE REPLACEMENT. (15th December 2022)
- Main Title:
- 1032 FEASIBILITY AND RELIABILITY OF COMPREHENSIVE THREE DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY SCREENING PROCESS FOR TRANSCATHETER MITRAL VALVE REPLACEMENT
- Authors:
- Boccellino, Antonio
Piroli, Francesco
Ingallina, Giacomo
Rolando, Marco
Melillo, Francesco
Francesco, Ancona
Stella, Stefano
Biondi, Federico
Baldetti, Luca
Palmisano, Anna
Esposito, Antonio
Denti, Paolo
Montorfano, Matteo
Maisano, Francesco
Castiglioni, Alessandro
Agricola, Eustachio - Abstract:
- Abstract: The procedural planning of transcatheter mitral valve replacement (TMVR) requires a specific imaging assessment to establish patient eligibility. Computed tomography (CT) is considered the reference method. In this setting, data regarding the role of transesophageal echocardiography (TEE) are lacking. Aims: To evaluate the feasibility and reliability of a comprehensive 3D-TEE screening in TMVR candidates. Methods: we performed a retrospective observational study including 72 consecutive patients who underwent a pre-procedural CT and 3D-TEE for TMVR evaluation. The measurements of mitral annulus (MA), length of anterior mitral leaflet (AML), native left ventricular outflow tract (LVOT) and predicted neo-LVOT acquired with CT and 3DTEE were compared using a novel semi-automated software for post processing analysis (3mensio Structural Heart 10.1 - 3mSH, Pie Medical Imaging, Bilthoven, Netherlands). The final suitability decision was given by the valve manufacturer based on CT measurements and clinical conditions. Results: Among 72 patients screened, all patients had adequate image quality for 3D-TEE analysis. 3D-TEE and CT measurements for AML length (r=0.97), MA area (r=0.90), perimeter (r=0.68), anteroposterior (r=0.88) and posteromedial-anterolateral (r=0.74) diameters were found highly correlated, as well as for native LVOT (r=0.86) and predicted neo-LVOT areas (r=0.96) (all P -values <0.0001). An almost perfect agreement among CT and 3d TEE was found inAbstract: The procedural planning of transcatheter mitral valve replacement (TMVR) requires a specific imaging assessment to establish patient eligibility. Computed tomography (CT) is considered the reference method. In this setting, data regarding the role of transesophageal echocardiography (TEE) are lacking. Aims: To evaluate the feasibility and reliability of a comprehensive 3D-TEE screening in TMVR candidates. Methods: we performed a retrospective observational study including 72 consecutive patients who underwent a pre-procedural CT and 3D-TEE for TMVR evaluation. The measurements of mitral annulus (MA), length of anterior mitral leaflet (AML), native left ventricular outflow tract (LVOT) and predicted neo-LVOT acquired with CT and 3DTEE were compared using a novel semi-automated software for post processing analysis (3mensio Structural Heart 10.1 - 3mSH, Pie Medical Imaging, Bilthoven, Netherlands). The final suitability decision was given by the valve manufacturer based on CT measurements and clinical conditions. Results: Among 72 patients screened, all patients had adequate image quality for 3D-TEE analysis. 3D-TEE and CT measurements for AML length (r=0.97), MA area (r=0.90), perimeter (r=0.68), anteroposterior (r=0.88) and posteromedial-anterolateral (r=0.74) diameters were found highly correlated, as well as for native LVOT (r=0.86) and predicted neo-LVOT areas (r=0.96) (all P -values <0.0001). An almost perfect agreement among CT and 3d TEE was found in assessing the eligibility for TMVR implantation (Cohen Kappa 0.83, p<0.001). Conclusions: 3D-TEE appraisements showed good correlations with CT measurements and high accuracy to predict TMVR screening success. Central Illustration . Mitral annulus segmentation and neo-LVOT area measurement performed by means of the 3mensio software (Pie Medical Imaging, Bilthoven, Netherlands) in a step-by-step fashion by TEE and CT imaging. After the virtual simulation of a valve implantation, the minimal systolic neo-LVOT area is manually measured by planimetry on a plane orthogonal to the centerline. … (more)
- Is Part Of:
- European heart journal supplements. Volume 24(2022)Supplement K
- Journal:
- European heart journal supplements
- Issue:
- Volume 24(2022)Supplement K
- Issue Display:
- Volume 24, Issue 11 (2022)
- Year:
- 2022
- Volume:
- 24
- Issue:
- 11
- Issue Sort Value:
- 2022-0024-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-12-15
- Subjects:
- Cardiology -- Periodicals
Cardiology -- Europe -- Periodicals
616.12005 - Journal URLs:
- http://eurheartjsupp.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartjsupp/suac121.162 ↗
- Languages:
- English
- ISSNs:
- 1520-765X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717510
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25023.xml