Accuracy and interrater reliability for the diagnosis of Barrett's neoplasia among users of a novel, portable high-resolution microendoscope. Issue 1 (1st January 2014)
- Record Type:
- Journal Article
- Title:
- Accuracy and interrater reliability for the diagnosis of Barrett's neoplasia among users of a novel, portable high-resolution microendoscope. Issue 1 (1st January 2014)
- Main Title:
- Accuracy and interrater reliability for the diagnosis of Barrett's neoplasia among users of a novel, portable high-resolution microendoscope
- Authors:
- Vila, P. M.
Kingsley, M. J.
Polydorides, A. D.
Protano, M.-A.
Pierce, M. C.
Sauk, J.
Kim, M. K.
Patel, K.
Godbold, J. H.
Waye, J. D.
Richards-Kortum, R.
Anandasabapathy, S. - Abstract:
- Summary: The high-resolution microendoscope (HRME) is a novel imaging modality that may be useful in the surveillance of Barrett's esophagus in low-resource or community-based settings. In order to assess accuracy and interrater reliability of microendoscopists in identifying Barrett's-associated neoplasia using HRME images, we recruited 20 gastroenterologists with no microendoscopic experience and three expert microendoscopists in a large academic hospital in New York City to interpret HRME images. They prospectively reviewed 40 HRME images from 28 consecutive patients undergoing surveillance for metaplasia and low-grade dysplasia and/or evaluation for high-grade dysplasia or cancer. Images were reviewed in a blinded fashion, after a 4-minute training with 11 representative images. All imaged sites were biopsied and interpreted by an expert pathologist. Sensitivity of all endoscopists for identification of high-grade dysplasia or cancer was 0.90 (95% confidence interval [CI]: 0.88-0.92) and specificity was 0.82 (95% CI: 0.79-0.85). Positive and negative predictive values were 0.72 (95% CI: 0.68-0.77) and 0.94 (95% CI: 0.92-0.96), respectively. No significant differences in accuracy were observed between experts and novices (0.90 vs. 0.84). The kappa statistic for all raters was 0.56 (95% CI: 0.54-0.58), and the difference between groups was not significant (0.64 vs. 0.55). These data suggest that gastroenterologists can diagnose Barrett's-related neoplasia on HRME imagesSummary: The high-resolution microendoscope (HRME) is a novel imaging modality that may be useful in the surveillance of Barrett's esophagus in low-resource or community-based settings. In order to assess accuracy and interrater reliability of microendoscopists in identifying Barrett's-associated neoplasia using HRME images, we recruited 20 gastroenterologists with no microendoscopic experience and three expert microendoscopists in a large academic hospital in New York City to interpret HRME images. They prospectively reviewed 40 HRME images from 28 consecutive patients undergoing surveillance for metaplasia and low-grade dysplasia and/or evaluation for high-grade dysplasia or cancer. Images were reviewed in a blinded fashion, after a 4-minute training with 11 representative images. All imaged sites were biopsied and interpreted by an expert pathologist. Sensitivity of all endoscopists for identification of high-grade dysplasia or cancer was 0.90 (95% confidence interval [CI]: 0.88-0.92) and specificity was 0.82 (95% CI: 0.79-0.85). Positive and negative predictive values were 0.72 (95% CI: 0.68-0.77) and 0.94 (95% CI: 0.92-0.96), respectively. No significant differences in accuracy were observed between experts and novices (0.90 vs. 0.84). The kappa statistic for all raters was 0.56 (95% CI: 0.54-0.58), and the difference between groups was not significant (0.64 vs. 0.55). These data suggest that gastroenterologists can diagnose Barrett's-related neoplasia on HRME images with high sensitivity and specificity, without the aid of prior microendoscopy experience. … (more)
- Is Part Of:
- Diseases of the esophagus. Volume 27:Issue 1(2014)
- Journal:
- Diseases of the esophagus
- Issue:
- Volume 27:Issue 1(2014)
- Issue Display:
- Volume 27, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 27
- Issue:
- 1
- Issue Sort Value:
- 2014-0027-0001-0000
- Page Start:
- 55
- Page End:
- 62
- Publication Date:
- 2014-01-01
- Subjects:
- cancer -- diagnostic imaging -- esophagogastroduodenoscopy -- optical device
Esophagus -- Diseases -- Periodicals
616.32 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1442-2050 ↗
http://www.wiley.com/bw/journal.asp?ref=1120-8694 ↗
https://academic.oup.com/dote ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/dote.12040 ↗
- Languages:
- English
- ISSNs:
- 1120-8694
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3598.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25014.xml