A novel method based on long short term memory network and discrete-time zeroing neural algorithm for upper-limb continuous estimation using sEMG signals. (May 2021)
- Record Type:
- Journal Article
- Title:
- A novel method based on long short term memory network and discrete-time zeroing neural algorithm for upper-limb continuous estimation using sEMG signals. (May 2021)
- Main Title:
- A novel method based on long short term memory network and discrete-time zeroing neural algorithm for upper-limb continuous estimation using sEMG signals
- Authors:
- Chai, Yuanyuan
Liu, Keping
Li, Chunxu
Sun, Zhongbo
Jin, Long
Shi, Tian - Abstract:
- Highlights: A closed-loop model based on sEMG comprised an LSTM network and discrete-time ZNN is developed. The continuous movement can be successfully estimated via the novel closed-loop model. The results show the closed-loop model is able to estimate the movement intention. Abstract: In this paper, a novel closed-loop model based on surface electromyography (sEMG) comprised a long short term memory (LSTM) network and discrete-time zeroing neural algorithm called zeroing neural network (ZNN), which is developed to estimate joint angles and angular velocities of human upper limb with joint damping. The dynamic model of human upper limb with joint damping is set up as the initial equation. Then, the LSTM network is proposed as an open-loop model which described the input-output relationship between the sEMG signals and joint motion intention. Besides, a novel closed-loop model is built via ZNN for eliminating the predicted error of open-loop model and improving the accuracy of motion intention recognition. Founded on the sEMG signals, the continuous movement of human upper limb joint can be successfully estimated via the novel closed-loop model. The results show that for simple joint movements, the closed-loop model is able to estimate the movement intention of human upper limb with high accuracy.
- Is Part Of:
- Biomedical signal processing and control. Volume 67(2021)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 67(2021)
- Issue Display:
- Volume 67, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 67
- Issue:
- 2021
- Issue Sort Value:
- 2021-0067-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05
- Subjects:
- SEMG -- LSTM network -- Discrete-time zeroing neural algorithm -- Human upper limb -- Motion intention recognition
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2021.102416 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24996.xml