Challenges in activation of remote monitoring in patients with cardiac rhythm devices during the coronavirus (COVID-19) pandemic. (1st April 2021)
- Record Type:
- Journal Article
- Title:
- Challenges in activation of remote monitoring in patients with cardiac rhythm devices during the coronavirus (COVID-19) pandemic. (1st April 2021)
- Main Title:
- Challenges in activation of remote monitoring in patients with cardiac rhythm devices during the coronavirus (COVID-19) pandemic
- Authors:
- Auricchio, Angelo
Conte, Giulio
Demarchi, Andrea
Baldi, Enrico
Özkartal, Tardu
Regoli, Francois
Moccetti, Tiziano - Abstract:
- Abstract: Background: Remote monitoring (RM) technology embedded in cardiac rhythm devices permits continuous monitoring of device function, and recording of selected cardiac physiological parameters and cardiac arrhythmias and may be of utmost utility during Coronavirus (COVID-19) pandemic, when in-person office visit for regular follow-up were postponed. However, patients not alredy followed-up via RM represent a challenging group of patients to be managed during the lockdown. Methods: We reviewed patient files scheduled for an outpatient visit between January 1, 2020 and May 11th, 2020 to assess the proportion of patients in whom RM activation was possible without office visit, and compared them to those scheduled for visit before the lockdown. Results: During COVID-19 pandemic, RM activation was feasible in a minority of patients (7.8% of patients) expected at outpatient clinic for a follow-up visit and device check-up. This was possible in a good proportion of complex implantable devices such as cardiac resynchronization therapy and implantable cardioverter defibrillator but only in a minority of patients with a pacemaker the RM function could be activated during the period of restricted access to hospital. Conclusions: Our experience strongly suggest to consider the systematic activation of RM function at the time of implantation or – by default programming - in all cardiac rhythm management devices. Highlights: Remote Monitoring is associated with improved survivalAbstract: Background: Remote monitoring (RM) technology embedded in cardiac rhythm devices permits continuous monitoring of device function, and recording of selected cardiac physiological parameters and cardiac arrhythmias and may be of utmost utility during Coronavirus (COVID-19) pandemic, when in-person office visit for regular follow-up were postponed. However, patients not alredy followed-up via RM represent a challenging group of patients to be managed during the lockdown. Methods: We reviewed patient files scheduled for an outpatient visit between January 1, 2020 and May 11th, 2020 to assess the proportion of patients in whom RM activation was possible without office visit, and compared them to those scheduled for visit before the lockdown. Results: During COVID-19 pandemic, RM activation was feasible in a minority of patients (7.8% of patients) expected at outpatient clinic for a follow-up visit and device check-up. This was possible in a good proportion of complex implantable devices such as cardiac resynchronization therapy and implantable cardioverter defibrillator but only in a minority of patients with a pacemaker the RM function could be activated during the period of restricted access to hospital. Conclusions: Our experience strongly suggest to consider the systematic activation of RM function at the time of implantation or – by default programming - in all cardiac rhythm management devices. Highlights: Remote Monitoring is associated with improved survival patients not followed-up via RM represent a challenging group of patients to be managed, specially during pandemic We strongly suggest to consider the systematic activation of RM function at the time of implantation or – by default programming - in all cardiac rhythm management devices … (more)
- Is Part Of:
- International journal of cardiology. Volume 328(2021)
- Journal:
- International journal of cardiology
- Issue:
- Volume 328(2021)
- Issue Display:
- Volume 328, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 328
- Issue:
- 2021
- Issue Sort Value:
- 2021-0328-2021-0000
- Page Start:
- 247
- Page End:
- 249
- Publication Date:
- 2021-04-01
- Subjects:
- Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2020.11.063 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24998.xml