Accuracy and acute efficacy of a novel occlusion tool to guide cryoballoon-based pulmonary vein isolation. (14th October 2021)
- Record Type:
- Journal Article
- Title:
- Accuracy and acute efficacy of a novel occlusion tool to guide cryoballoon-based pulmonary vein isolation. (14th October 2021)
- Main Title:
- Accuracy and acute efficacy of a novel occlusion tool to guide cryoballoon-based pulmonary vein isolation
- Authors:
- Rottner, L
Moser, F
Schleberger, R
Weimann, J
Moser, J
Lemoine, M
Muenkler, P
Dinshaw, L
Risius, T
Kirchhof, P
Ouyang, F
Reissmann, B
Metzner, A
Rillig, A - Abstract:
- Abstract: Background: Cryoballoon (CB)-based pulmonary vein isolation (PVI) currently requires to verify occlusion of each pulmonary vein (PV) using fluoroscopy and dye injection. Objective: The current study evaluated whether the novel CB-occlusion tool integrated into the wide-band dielectric imaging system KODEX-EPD reliably verifies occlusion of PV according to a novel dye-injection based algorithm. Methods: Consecutive patients suffering from symptomatic atrial fibrillation (AF) underwent CB-based PVI using the KODEX-EPD and the novel occlusion-tool (group I). To confirm accurate display of the PVs, selective PV-angiography was performed in the first half of the patients of group I (group Ia) in addition to a three-dimensional left atrial (LA) map using a spiral mapping catheter (Achieve, SMC1, Medtronic, MN, USA). PV-angiographies were waived for the following patients (group Ib). Procedural duration and radiation exposure were compared to a control group of patients undergoing conventional CB-based PVI. Results: CB-based PVI was successful in 50/50 patients of group I (mean age 63±11 years, 18 paroxysmal (36%)) and 25/25 patients of group II (66±10 years, 9 paroxysmal (60%)). Concordance of PV-occlusion as assessed by either PV-occlusion-angiography or KODEX-EPD, was documented in 237/272 (87%) occlusion-analyses among 198 PVs (95% for left superior PV, 93% for left inferior PV, 86% for right inferior PV and 77% for right superior PV). In the final evaluation phaseAbstract: Background: Cryoballoon (CB)-based pulmonary vein isolation (PVI) currently requires to verify occlusion of each pulmonary vein (PV) using fluoroscopy and dye injection. Objective: The current study evaluated whether the novel CB-occlusion tool integrated into the wide-band dielectric imaging system KODEX-EPD reliably verifies occlusion of PV according to a novel dye-injection based algorithm. Methods: Consecutive patients suffering from symptomatic atrial fibrillation (AF) underwent CB-based PVI using the KODEX-EPD and the novel occlusion-tool (group I). To confirm accurate display of the PVs, selective PV-angiography was performed in the first half of the patients of group I (group Ia) in addition to a three-dimensional left atrial (LA) map using a spiral mapping catheter (Achieve, SMC1, Medtronic, MN, USA). PV-angiographies were waived for the following patients (group Ib). Procedural duration and radiation exposure were compared to a control group of patients undergoing conventional CB-based PVI. Results: CB-based PVI was successful in 50/50 patients of group I (mean age 63±11 years, 18 paroxysmal (36%)) and 25/25 patients of group II (66±10 years, 9 paroxysmal (60%)). Concordance of PV-occlusion as assessed by either PV-occlusion-angiography or KODEX-EPD, was documented in 237/272 (87%) occlusion-analyses among 198 PVs (95% for left superior PV, 93% for left inferior PV, 86% for right inferior PV and 77% for right superior PV). In the final evaluation phase (group Ib) LA fluoroscopy times and dose area products were comparable to the conventional CB-ablation group (10.5±5 vs 8.8±4 minutes (p=0.23) and 403±425 vs 321±202 cGycm 2 (p=0.44), whereas the amount of dye could be significantly reduced (group Ib: 31±10 ml vs group II: 70±20 ml, p<0.0001). Conclusion: The novel KODEX-EPD PV-occlusion tool allows for accurate PV-occlusion assessment in the majority of PVs and a high acute success rate. The system has the potential to reduce dye and radiation exposure. This should be evaluated in controlled clinical trials. Funding Acknowledgement: Type of funding sources: None. … (more)
- Is Part Of:
- European heart journal. Volume 42(2021)Supplement 1
- Journal:
- European heart journal
- Issue:
- Volume 42(2021)Supplement 1
- Issue Display:
- Volume 42, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2021-0042-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-14
- Subjects:
- Catheter Ablation of Arrhythmias
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehab724.0354 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25015.xml