High incidence of inappropriate alarms in patients with wearable cardioverter-defibrillators: findings from the swiss WCD registry. (14th October 2021)
- Record Type:
- Journal Article
- Title:
- High incidence of inappropriate alarms in patients with wearable cardioverter-defibrillators: findings from the swiss WCD registry. (14th October 2021)
- Main Title:
- High incidence of inappropriate alarms in patients with wearable cardioverter-defibrillators: findings from the swiss WCD registry
- Authors:
- Kovacs, B
Burri, H
Reek, S
Sticherling, C
Linka, A
Ammann, P
Mueller, A.S
Kobza, R
Haegeli, L
Mayer, K
Eriksson, U
Reichlin, T
Steffel, J
Saguner, A.M
Duru, F - Abstract:
- Abstract: Introduction: The wearable cardioverter defibrillator (WCD) uses surface electrodes built into the vest to detect underlying arrhythmia before initiating a treatment sequence. However, it is also prone to inappropriate detection due to artefacts. Purpose: The aim of this study was to assess the alarm burden in patients and its possible impact on clinical outcomes. Methods: The Swiss WCD Registry is a nationwide, retrospective, observational registry. Patients were included from December 2011 until February 2018. Clinical characteristics and data from the WCDs, including alarm burden were analysed. Recordings ≥30 seconds of length were analysed and categorized as VT/VF, atrial fibrillation (AF), supraventricular tachycardia or artefact. Results: A total of 10'653 device alarms were documented in 324 of 456 patients (71.1%) over a mean WCD wear-time of 2.0±1.6 months. Among these, the episode duration was 30 seconds or more in 2996 (28.2%). One hundred and eleven (3.7%) were VT/VF episodes. The remaining recordings were inappropriate arrhythmia detections (2736 (91%) due to artefacts; 117 (3.7%) AF; 48 (1.6%) supraventricular tachycardia). Two-hundred and seven patients (45.0%) had 3 or more alarms per month, whereas 49 patients (10.7%) had 1 or more alarms per day. Body mass index (BMI) was significantly higher in patients with 3 or more alarms per month (p=0.002, 25.6 vs. 27.3 kg/m 2 ) High alarm burden was not associated with a lower average daily wear time (20.8Abstract: Introduction: The wearable cardioverter defibrillator (WCD) uses surface electrodes built into the vest to detect underlying arrhythmia before initiating a treatment sequence. However, it is also prone to inappropriate detection due to artefacts. Purpose: The aim of this study was to assess the alarm burden in patients and its possible impact on clinical outcomes. Methods: The Swiss WCD Registry is a nationwide, retrospective, observational registry. Patients were included from December 2011 until February 2018. Clinical characteristics and data from the WCDs, including alarm burden were analysed. Recordings ≥30 seconds of length were analysed and categorized as VT/VF, atrial fibrillation (AF), supraventricular tachycardia or artefact. Results: A total of 10'653 device alarms were documented in 324 of 456 patients (71.1%) over a mean WCD wear-time of 2.0±1.6 months. Among these, the episode duration was 30 seconds or more in 2996 (28.2%). One hundred and eleven (3.7%) were VT/VF episodes. The remaining recordings were inappropriate arrhythmia detections (2736 (91%) due to artefacts; 117 (3.7%) AF; 48 (1.6%) supraventricular tachycardia). Two-hundred and seven patients (45.0%) had 3 or more alarms per month, whereas 49 patients (10.7%) had 1 or more alarms per day. Body mass index (BMI) was significantly higher in patients with 3 or more alarms per month (p=0.002, 25.6 vs. 27.3 kg/m 2 ) High alarm burden was not associated with a lower average daily wear time (20.8 hours vs 20.7 hours, p=0.785) or a decreased implantable cardioverter defibrillator implantation rate after stopping WCD use (48% vs 47.3%, p=0.156). Conclusions: In patients using WCDs, alarms emitted by the device and impending inappropriate shocks were frequent and most commonly caused by artefacts. A high alarm burden did not lead to a decreased adherence, as determined by average daily wear-times. Obesity was significantly associated with a higher alarm burden. Funding Acknowledgement: Type of funding sources: None. … (more)
- Is Part Of:
- European heart journal. Volume 42(2021)Supplement 1
- Journal:
- European heart journal
- Issue:
- Volume 42(2021)Supplement 1
- Issue Display:
- Volume 42, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2021-0042-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-14
- Subjects:
- Device Treatment
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehab724.0668 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25015.xml