Comparison of mortality prediction scores in elderly patients with ICD for heart failure with reduced ejection fraction. (14th October 2021)
- Record Type:
- Journal Article
- Title:
- Comparison of mortality prediction scores in elderly patients with ICD for heart failure with reduced ejection fraction. (14th October 2021)
- Main Title:
- Comparison of mortality prediction scores in elderly patients with ICD for heart failure with reduced ejection fraction
- Authors:
- Hayiroglu, M.I
Cinar, T
Cinier, G
Pay, L
Yumurtas, A.C
Tezen, O
Eren, S
Kolak, Z
Cetin, T
Ozcan, K.S
Turkkan, C
Ozbilgin, N
Tekkesin, A.I
Alper, A.T
Gurkan, K - Abstract:
- Abstract: Background: This investigation aimed to examine and compare the predictive value of MADIT-II, FADES, PACE and SHOCKED scores in predicting 1-year and long-term all-cause mortality in implantable cardioverter-defibrillator (ICD) implanted patients who were 75 years and over since there has been an area of uncertainty about the utility and usefulness of available risk scores in such cases. Methods: In this observational, retrospective study, ICD implanted 189 geriatric patients are divided into two groups according to the presence of long-term mortality in follow-up. The baseline characteristics and laboratory variables were compared between the groups. MADIT-II, FADES, PACE and SHOCKED scores were calculated at the time of ICD implantation. 1-year and long-term predictive value of these scores were compared by a receiver operating curve (ROC) analysis. Results: A ROC analysis showed that the best cut-off value of the MADIT-II score to predict 1-year mortality is 3 with 87% sensitivity and 74% specificity (AUC: 0.83; 95% CI: 0.73–0.94; p<0.001) and long-term mortality is 2 with 83% sensitivity and 43% specificity (AUC: 0.68; 95% CI: 0.60–0.76; p<0.001) The predictive value of MADIT-II was superior to FADES, PACE and SHOCKED scores in ICD implanted patients who are 75 years and over. Conclusion: MADIT-II score has a significant prognostic value compared to FADES, PACE and SHOCKED scores for the prediction of 1-year and long-term follow-up in geriatric patientsAbstract: Background: This investigation aimed to examine and compare the predictive value of MADIT-II, FADES, PACE and SHOCKED scores in predicting 1-year and long-term all-cause mortality in implantable cardioverter-defibrillator (ICD) implanted patients who were 75 years and over since there has been an area of uncertainty about the utility and usefulness of available risk scores in such cases. Methods: In this observational, retrospective study, ICD implanted 189 geriatric patients are divided into two groups according to the presence of long-term mortality in follow-up. The baseline characteristics and laboratory variables were compared between the groups. MADIT-II, FADES, PACE and SHOCKED scores were calculated at the time of ICD implantation. 1-year and long-term predictive value of these scores were compared by a receiver operating curve (ROC) analysis. Results: A ROC analysis showed that the best cut-off value of the MADIT-II score to predict 1-year mortality is 3 with 87% sensitivity and 74% specificity (AUC: 0.83; 95% CI: 0.73–0.94; p<0.001) and long-term mortality is 2 with 83% sensitivity and 43% specificity (AUC: 0.68; 95% CI: 0.60–0.76; p<0.001) The predictive value of MADIT-II was superior to FADES, PACE and SHOCKED scores in ICD implanted patients who are 75 years and over. Conclusion: MADIT-II score has a significant prognostic value compared to FADES, PACE and SHOCKED scores for the prediction of 1-year and long-term follow-up in geriatric patients implanted ICD for heart failure with reduced ejection fraction. Funding Acknowledgement: Type of funding sources: None. … (more)
- Is Part Of:
- European heart journal. Volume 42(2021)Supplement 1
- Journal:
- European heart journal
- Issue:
- Volume 42(2021)Supplement 1
- Issue Display:
- Volume 42, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2021-0042-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-14
- Subjects:
- Device Treatment
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehab724.0667 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 25015.xml